15. Set information(Serial No & Model name)
(1) Setting up like bottom figure (After setting white balance,
this is set)
1) Press ADJ Key in the Adjust remocon.
2) Select "System Control 2" by using
A
and press
(ENTER).
3) Using Adjust remocon, RS-232 Host & Baud Rate &
Download value change (RS-232 Host:Gprobe, Baud
Rate:115200bps, Download:Cortez)

(2) Bar-code scanning

1) Push the menu button in DTV mode.
Select the STATION -> Diagnostics -> To set
2) Check the Serial Number.
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes

16. Select method of Tool option

(1) Press ADJ Key in the Adjust remote control.
(2) Select "Tool option 1" and "Tool option2" by using
D
E
/
(CH+/-) key,
(3) TOOL OPTION1
(4) TOOL OPTION2
( Inch of model : "42,50" Applied module under the calassificatoin : )
6) After changing the Tool option1,2, push the EXIT Key.
- 12 -
A
(CH+/-) key, and press
1) Select "Maker" by using
the module maker and. applied module classification by
F
G
using
/
(VOL+/-).
2) Select "Inch" by using
module according to the inch of model.
1) Select "TOOL NUM" by using
change the module maker and. applied module
classification by using
2) Select "FAN" by using
module according to the inch of model.
3) Select "DIGITAL" by using
the tool name according to the model.
Tool option1
Maker
2048
LGX4
2052
LGX4
Tool option2
Suffix
1665
KE*L(Y)LMP
1921
KE*L(Y)LMP
1665
KE*FLMP
(ENTER).
D
/
E
(CH+/-) key, and change
D
E
/
(CH+/-) key, and change the
D
E
/
(CH+/-) key, and
F
G
/
(VOL+/-).
D
/
E
(CH+/-) key, change the
D
/
E
(CH+/-) key, and change
Inch
Tool
42
PT85
50
PT85
FAN
DIGITAL AMP
0
1
1
1
0
1
LGE Internal Use Only