GENERAL SPECIFICATION
Engine
Number of cylinders
Bore of cylinders
Stroke of crankshaft
Cubic capacity
Piston area
Compression ratio
Valve rocker clearances
(cold)
Valve timing
Lubrication (Engine)
Pump
Filter
Cooling System
Circulation
Fan
TR6 1976 FEDERAL GENERAL SPECIFICATION
6
74.7 mm.
2.94 in.
95.0 mm.
3.74 in.
2498 cm.3
152 in.3
263 cm.2
40.7 in.2
7.5 : 1
0.25 mm.
0.010 in.
Inlet and exhaust equally open at
T.D.C.
High capacity rotor pump
Full flow replacable element
Pressurised "no-loss" system incor-
porating a translucent plastic over-
flow bottle.
By impellor pump thermostatically
controlled flow
13 blades, 14.5 in. dia. (368 mm.)
vee belt drive from crankshaft pulley
Fuel System
Pump
A.C. mechanically operated dia-
phragm type
Carburetter
Stromberg 2
X
175 C.D.S.E.V. side
draught
Manifolds
Cast aluminium inlet manifold and
cast iron exhaust manifold
Air cleaners
Replaceable paper elements
Crankcase breathing
Closed circuit breathing from rocker
cover to constant depression cham-
bers of carburetters
Ignition System
Coil
Distributor-type
contact gap
dwell angle
rotation-viewed
on
top of the rotor
Firing order
Sparking plugs-type
gap
Ignition timing-static
idle
Lucas 15c6 with Ballast Resister wire
Lucas
in harness
0.63 mm.
0.015 in. nominal
34-38"
Anti-clockwise
1-5-3-6-2-4
N9Y (Champion)
0.63 mm.
0.025 in, nominal
10" B.T.D.C.
4"