800-460-9011 apswater.com D-Series Economy Reverse Osmosis Systems Operating and Installation Manual System Flow Rate Model Number 10 Gallons Per Day RO10D1 50 Gallons Per Day RO50D1 75 Gallons Per Day RO75D1 100 Gallon Per Day RO1XD1 7320 Valjean Ave, Lake Balboa California 91406 – 800-460-9011 Toll Free...
APSWATER 800-460-9011 apswater.com Introduction Please read this entire service guide prior to beginning installation. The D-Series economy reverse osmosis water system has been designed for quick and simple installation and maintenance. By carefully reading this instruction manual and following the operational guidelines you will ensure a successful installation and reliable operation.
Page 3
APSWATER 800-460-9011 apswater.com About Your RO System Stages & Connection Points Installation Diagram 5 Stage Reverse Osmosis Water System Stage Description Replacement Schedule Stage Sediment pre-filter Every 3-6 months Stage Carbon block pre-filter Every 3-6 months Stage Carbon block pre-filter...
APSWATER 800-460-9011 apswater.com Preparing For Installation Check the following list of components to ensure that all parts are packed with your system. RO System Storage Tank Faucet Kit Feed Adapter Kit Tubing: Blue, Yellow, Drain Saddle Tank Valve Filter Wrench Orange &...
APSWATER 800-460-9011 apswater.com System Mounting Determine whether mounting the system to the wall is necessary or desired. This can be optional. Dry wall anchors and screws may be necessary (not included with the system). 1. Mark screw locations at the desired positions. Use the two holes on the back of the RO System mounting bracket for marker guides.
Page 6
APSWATER 800-460-9011 apswater.com 7320 Valjean Ave, Lake Balboa California 91406 – 800-460-9011 Toll Free Page 6 Of 23...
APSWATER 800-460-9011 apswater.com Starting Your Installation 1. Shut Off the Water a. Locate the valve in the cold water feed line you use for the supply. Accidentally hooking up the system to the hot water supply line will permanently damage the membrane (see conditions for operation). To assure you are using the cold water line, turn on both the hot and cold faucet.
APSWATER 800-460-9011 apswater.com Feed Adapter Installation For this, step, you will need: o Wrench o Teflon Tape Feed Adapter Kit Blue Tubing Slip Joint Adapter (with washer) Ball Valve (with nut) Install the ball valve into the slip joint adapter.
Page 9
APSWATER 800-460-9011 apswater.com 4. Connect the other end of the blue tubing to the feed port on the RO System. Feed Valve OPEN Position Feed Valve CLOSED Position 7320 Valjean Ave, Lake Balboa California 91406 – 800-460-9011 Toll Free Page 9 Of 23...
APSWATER 800-460-9011 apswater.com Drain Saddle Installation For this step you will need: o Variable speed drill w/ ⅛” and ¼" drill bits o Phillips Screwdriver Drain Saddle Assembly Black Tubing 1. Drill a ¼” hole in the drain pipe Select a location for the drain hole based on the design of the plumbing.
Page 11
APSWATER 800-460-9011 apswater.com 3. Install the drain tubing. a. Slide the black nut onto the end of the black plastic tubing, threads facing outward. Insert the end of the black tubing into the fitting on the drain saddle. c. Secure the connection by tightening the nut onto the threaded fitting.
Page 12
APSWATER 800-460-9011 apswater.com Mounting the Tank Ball Valve & Connecting the Tank For this step you will need: Tank Valve Assembly Storage Tank Orange Tubing Note: Do not tamper with the air valve on the low side of the storage tank. It has been factory charged and covered with a black cap.
APSWATER 800-460-9011 apswater.com Faucet Installation For this, step, you will need: o Wrench o Variable speed drill w/ ⅛” and ” drill bits Faucet Assembly Kit Yellow Tubing 1. Determine the desired location for your RO Faucet The product water faucet may be installed on any flat surface at least 2” in diameter. Check the underside of the location for interference.
APSWATER 800-460-9011 apswater.com Turning the System On for the First Time Make sure all water supply /drain lines are secure and free from leaks. Slowly turn the feed valve counterclockwise until fully open (the handle should be in line with the tubing as it enters the connection).
APSWATER 800-460-9011 apswater.com System Maintenance Membrane Replacement Instructions The membrane should be replaced every 1-2 years, depending on the water quality. Before starting, shut off the cold water supply to the unit. Lift the handle on the faucet to drain out the storage tank completely and allow the system to stand for 10 minutes in order to fully decompress the tank.
APSWATER 800-460-9011 apswater.com Troubleshooting Chart Symptom Possible Cause Remedy No water in the storage tank Filter Cartridges have failed. Replace filter cartridges as indicated in maintenance section. Cartridges are out of Install cartridges in proper sequence as sequence. indicated in system components.
Replace every 3-6 months Replace every 3-6 months Replacement Membranes & Flow Restrictors System Model Replacement Replacement Flow Rate Number Membrane Model Flow Restrictor 10 GPD RO10D1 TLC-10 H-R2051QC 50 GPD RO50D1 TLC-50 H-R2065QC 75 GPD RO75D1 TLC-75 H-R2069QC 100 GPD...
Page 19
APSWATER 800-460-9011 apswater.com Optional Deionizer Add On Products DI Add on (or stand alone) DI1041 Includes : Filter Housing 2 ea ¼” Tubing Fittings Mounting Bracket MB1001 Deionizer Filter QC Light Kit QCKT41 Includes : 200K Resilite 1/2” Tee 2 ea. ¼” X ½” reducer bushings 2 ea.
Page 20
APSWATER 800-460-9011 apswater.com Optional Add on Deionizer Hook Up Schematics When using a metal faucet on deionized water please be aware that it is better to use a plastic PVC faucet (DIFCK1) due to recontamination of the water by the minerals from the faucet.
Page 21
APSWATER 800-460-9011 apswater.com When using a metal faucet on deionized water please be aware that it is better to use a plastic PVC faucet (DIFCK1) due to recontamination of the water by the minerals from the faucet. Important All Filter Housings are marked “IN” and “OUT” on the top”. This is intended for sediment filters and not for deionizer filters or other granular filters.
Page 22
APSWATER 800-460-9011 apswater.com This is the default setup that the system was designed for Important All Filter Housings are marked “IN” and “OUT” on the top”. This is intended for sediment filters and not for deionizer filters or other granular filters. You must reverse the flow for granular filters so it is important to connect the feed line to the port marked “OUT”...
Product Warranty SELLER hereby warrants to CUSTOMER that the goods herein described will be free from any liens or encumbrances, that good title to said goods will be conveyed to CUSTOMER by sale of same. SELLER warrants materials of its own manufacture against defects in material and workmanship under normal conditions of usage and service as specified in this manual for one year from whichever of the following events occur first: ...