CHECKING FLOW CHART BY FAILURE
Symptom
1. Oven hot
2. F6
1. Check the Resistance of the Relay.
2. Check the Sensor's Resistance
Relay Short check
9-19
Check Point
ⓐ ⓐ
ⓐ ⓐ
Location
CN103 ① ~ ②
CN103 ① ~ CN102 ①
CN103 ① ~ CN102 ②
CN103
CN102
1 2
1
2
CN100
1
2
1
CN101
Resistance[Ω]
∞
∞
∞