Download Print this page

Aube Technologies Power Base PB1 30-024T Installation Instructions page 2

Aube technologies inc. power base installation instructions

Advertisement

C on trol M od u l e
Heating
Command
Indicator Light
ON/OFF
Switch
Power Selection Dial
The TH131-R regulator operates on perpetual 15-minute
or 15-second heating cycles.
For example (15-minute cycles), if the
dial is set halfway, the system will
heat for 50% of the cycle; it will be ON
for 7.5 minutes and OFF for 7.5
minutes.
Below is a detailed table of the cycle
duration based on the dial's position:
Position and
I
2
4
6
8
equivalent %
0%
20%
40%
60%
80%
ON
0 min
3 min
6 min
9 min 12 min 15 min
OFF
15 min 12 min 9 min
6 min
3 min
NOTE:
Depending on the power base used, the heating
cycles can be 15 seconds or 15 minutes.
Thank you for choosing Aube's TH131-R regulator.
The TH131-R is specially designed to control an electric
floor heating installation, a baseboard or a convector.
The TH131-R regulator operates like a dimmer switch to
allow you to easily adjust the amount of power sent to
your heating system.
This control module can be used with a line voltage power
base (230 V European models) or a low voltage power
base (24 V) combined with an electromechanical or triac
relay.
Model: TH131-R
Setting
Range: from 0 to 100%
Storage: -4°F to 120°F (-20°C to 50°C)
Heating
cycles: 15-minute or 15-second
Size
(H/W/D): 3,1 x 3,1 x 0,64 in. (78,9 x 78,9 x 16,3 mm)
10
Electric Heating Solid State Relay:
100%
RT850
this model handles 100 to 347 V.
RT850T
this model has a built-in 24 V transformer and is
0 min
available in 240, 277 and 347 V.
Electric Heating Electromechanical Relays:
RC840
this model handles 120 to 347 V.
RC840T
this model has a built-in 24 V transformer and is
available in 240, 277 and 347 V.
Located in the lower-right corner of the
control module, this switch is used to
select the heating cycle based on the
power base.
230 V LINE VOLTAGE BASE
ALWAYS 15 minutes
24 V LOW VOLTAGE BASE
• 15 MIN
Use with a triac or electromechanical relay.
Recommended for mechanical actuated system
(water heating using a solenoid valve, etc.) or a
fan-forced heater.
• 15 SEC
Use only for installations with SSR TRIAC relay.
Recommended for electric heating (baseboards,
convectors, etc.).
The TH131-R is equipped with an ON/OFF switch making
it possible to turn off the regulator when its use is not
required (e.g. summer).
AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED
WARRANTY
This product is guaranteed against workmanship defects
for a two-year period following the initial date of purchase.
During this period, AUBE Technologies Inc. will repair or
replace, at our option and without charge, any defective
product which has been used under normal conditions.
The warranty does not cover delivery costs and does not
apply to products poorly installed or randomly damaged
following installation.
This warranty cancels and replaces any other manufac-
turer's express or implied warranty as well as any other
company commitment. AUBE Technologies Inc. cannot
be held liable for related or random damages following the
installation of this product.
The defective product as well as the purchase invoice
must be returned to the place of purchase or mailed, pre-
paid and insured, to the nearest address.
Align the bracket tabs on the control module with the
holes located on the power base and secure using the
screw.
Air Vents
Control Module
Air Vents
Power Base
NOTE:
Keep the regulator's air vents clean and free from
obstructions.
NOTE:
The screw cannot be removed completely.
If you have any questions concerning the TH131-R
regulator, call our technical support team at:
705 Montrichard
10 rue Ampère
Saint-Jean-sur-Richelieu
95500 Gonesse
(Quebec) Canada
France
J2X 5K8
Tel.:
(450) 358-4600
33 (0) 1 34 07 99 00
1-800-831-AUBE
33 (0) 1 34 07 99 19
Fax:
(450) 358-4650
service@aubetech.com
advaube@comintes.com
For more information on our products, visit us at
www.aubetech.com
19/12/03
400-131-008-A

Advertisement

loading

This manual is also suitable for:

3184873