Download Print this page
Omnitron Systems Technology E1 User Instructions

Omnitron Systems Technology E1 User Instructions

Flexpoint t1/e1 copper to fiber converters

Advertisement

Quick Links

Power Adapter Notice
1. When Using in a stand-alone configuration, this product
is intended to be and must be used only with a Listed
TM
FlexPoint
T1/E1 Copper to Fiber
Direct Plug-In Power Unit marked "Class 2" and rated
Converters
at 9VDC, 1 Amp.
2. This product should always be used only with Omnitron
User Instructions
Supplied Power Unit model numbers 9113-PS or 9115-PS.
Description:
The FlexPoint T1/E1 connects T1 and E1 devices, such as
Before inserting the Power Adapter, verify that the
PBXs, CSUs and routers, via multimode (MM) or single-mode
(SM) fiber. Designed to extend the standard T1/E1 twisted pair
power on the unit is appropriate for your AC line
or Coax network distances over fiber, this converter provides
protection from environmental noise and effectively increases
high-speed network reliability. The following models are
described here.
Mounting instructions:
Model #
Fiber Type
Max Distance
The FlexPoint Fiber Converter can be solo-mounted using
4470/90-x
MM, SC, 1310nm
5km
a wall-mounting kit, or rack-mounted using a 5-unit shelf,
4471/91-x
SM, SC, 1310nm
30km
or a high-density FlexPoint 14-Unit Power-Redundant
4472/92-x
MM, ST, 1310nm
5km
Chassis.
4473/93-x
SM, ST, 1310nm
30km
Fiber Optic Cable Attachment:
4474/94-x
SM, SC, 1310nm, LH
60km
Connect the fiber cables between the FlexPoint T1/E1
Power Options (-x):
converters. The transmit (Tx) must attach to the receive
-0 No power adapter included (chassis module)
side and the receive (Rx) must attach to the transmit side.
-1 110 Volt / 60 Hz
Note: Use fiber cables that are compliant with the
-2 110-230 Volt / 50 Hz
specifications that are outlined in fiber cable specifications.
Mounting Options
Copper Cable Attachment:
4380
FlexPoint Wall-Mounting Hardware Kit
RJ-45/RJ-48 T1/E1 connector
4384
FlexPoint 18 to 72VDC Stand-Alone Power Supply
4381
FlexPoint DC Converter Wall-Mounting Kit (for 4384)
Connect to the RJ-45/48 connector on the FlexPoint T1/
4385
FlexPoint 14-Unit 48VDC Power-Redundant Chassis
E1 converter via a category 3 or better cable (Category
4392
FlexPoint 5-Unit Rack-Mounting Shelf
5 is recomended) and attach the other end to the network
4395
FlexPoint 14-Unit AC Power-Redundant Chassis
Local loop-back and Remote loop-back
LED Indicators
When both Local and Remote Loop-back are set to the
LED
Color
Normal position, the FlexPoint T1/E1 uses the default B8ZS
Power:
data format. When both switches are turned to their On
Yellow
position, it uses the AMI data format.
Fiber:
Transmit/force 1's to fiber
Green
This switch is used to insert an "all ones" pattern into the
data stream being transmitted out of the fiber port on the
FlexPoint T1/E1 converter. Data being received on the coax
UTP/Coax:
or twisted pair will be disabled and data being received on
Green
the fiber is passed through to the coax or twisted pair side.
By returning the switch to the normal position the unit will
resume to normal operation.
Test:
Transmit/force 1's to Coax or UTP
Green
This switch is used to insert an "all ones" pattern into the
data stream being transmitted out of the coax or twisted
pair on the FlexPoint T1/E1 converter. Data being received
on the fiber will be disabled and data being received on
Fiber Cable Specifications:
the coax or twisted pair is passed through to the fiber side.
Multimode
By returning the switch to the normal position the unit will
resume to normal operation.
Cable:
Alarm Relay Contacts
Wavelength:
The FlexPoint T1/E1 features dry relay contacts for
Max Distance:
optionally connecting the it into a separate T1/E1 alarm
Singlemode
circuit. The relay closes when a loss of power or when
Cable:
signal detect is lost to the copper or fiber connection.
Wavelength:
Relay
RJ-45/RJ-48
Max Distance:
3
Singlemode long-haul
Cable:
6
Wavelength:
Max Distance:
Operational rating on relay pins 3 & 6: 0-220VDC max 2A
equipment. (The twisted pair connection requires two active
pairs in a T1/E1 environment. The active pairs are pins
1&2 and pins 4&5. Only dedicated wire pairs should be
used for the active pins.) Set the UTP DCE / DTE switch
for the RJ-45/48 port to the appropriate setting.
Note: Use copper cables that are compliant with the
specifications that are outlined in copper cable specifications.
Coax E1 Connector
WARNING!
Attach the BNC to the FlexPoint T1/E1 converter and attach
the other end of the BNC to the network equipment.
Note: Use copper cables that are compliant with the
specifications that are outlined in copper cable specifications.
voltage source.
Switch Settings:
UTP DCE/DTE setting
The UTP DCE/DTE switch is used to eliminate the need for
crossover and custom cables to connect devices together when
using the RJ-45/48 port. Set this switch to DCE to use a
straight-through cable and to DTE when a crossover-cable
would be required.
DCE
Twisted
1
RTIP
TTIP
Pair #1
2
RRING
TRING
Twisted
4
TTIP
RTIP
5
Pair #2
TRING
RRING
T1/E1 Copper line configuration settings
The T1/E1 copper line codes and line lengths are configured
using dip switches located on the side of the FlexPoint T1/E1
media converter.
Copper Cable Specifications:
Status
Description
Twisted-Pair cable for T1
Gauge
On
Power applied
Impedance
Impedance characteristic
Off
No signal detect
Maximum distance
On
Signal detect
Twisted-Pair cable for E1
Blink
All ones received
Gauge
Off
No signal detect
Impedance
On
Signal detect
Impedance characteristic
Blink
All ones received
Maximum distance
Coax cable for E1
Off
Normal operation
Gauge
On
L/LB or All 1's Test mode
Blink
R+L/LB Received master
Impedance
Fast Blink
R+L/LB Received slave
Impedance characteristic
Maximum distance
For product specifications refer to the product data sheet.
50/125, 62.5/125, 100/140 μm
Technical Support:
1310nm
For help with this product, contact our Tech. Support:
5km
Phone:
(949) 250-6510
Fax:
(949) 250-6514
9/125 μm
Address:
Omnitron Systems Technology, Inc.
1310nm
140 Technology Drive, #500
30km
Irvine, CA 92618 USA
E-mail:
support@omnitron-systems.com
9/125 μm
URL:
http://www.omnitron-systems.com
1310nm
60km
Line Type
Port Type
Distances
T1 DSX-1
RJ-45/48
0' - 133'
T1 DSX-1
RJ-45/48
133' - 266'
T1 DSX-1
RJ-45/48
266' - 399'
T1 DSX-1
RJ-45/48
399' - 533'
T1 DSX-1
RJ-45/48
533' - 655'
T1 DS-1
RJ-45/48
0 dB
T1 DS-1
RJ-45/48
-7.5 dB
T1 DS-1
RJ-45/48
-15.0 dB
T1 DS-1
RJ-45/48
-22.5 dB
E1 75 Ω
Coax/BNC Standard
E1 120 Ω
RJ-45/48
Standard
E1 75 Ω
Coax/BNC Extended
E1 120 Ω
RJ-45/48
Extended
Operational switch settings and functions
DTE
The following operational switches located on the front of
the FlexPoint T1/E1 converter are to assist in installation
and fault isolation.
Twisted
1
RTIP
TTIP
Pair #1
2
RRING
TRING
Twisted
4
TTIP
RTIP
5
Pair #2
TRING
RRING
Local Dual Loop Back
Remote & Local Loop Back
Normal
Force 1's to Fiber
Force 1's Copper
Warning
The operating description in this Instruction Manual is for use
22 to 24 AWG
by qualified personnel only. To avoid electrical shock, do not
Ω
100
+ 10%
perform any servicing of this unit other than that contained in
2.6 dB / 100m @ 1.0 MHz
the operating instructions, unless you are qualified and certified
to do so by Omnitron Systems Technology, Inc.
6,000 ft
Caution
22 to 24 AWG
All user-required operations can be performed without opening
120
Ω
+ 10%
the unit. Never attempt to open or remove the cover or tamper
with the unit.
2.6 dB / 100m @ 1.0 MHz
8,000 ft
Warranty
This product is warranted to the original purchaser against
defects in material and workmanship for a period of TWO
22 to 24 AWG
YEARS from the date of shipment. A LIFETIME warranty may
75
Ω
+ 10%
be obtained by the original purchaser by REGISTERING this
2 dB / 100m @ 1.0 MHz
product with Omnitron within 90 days from the date of shipment.
8,000 ft
TO REGISTER, COMPLETE AND MAIL OR FAX THE
REGISTRATION PORTION OF THIS INSTRUCTION
MANUAL TO THE INDICATED ADDRESS. Or you may
register your product on the Internet at http://www.omnitron-
systems.com. During the warranty period, Omnitron will, at its
option, repair or replace a product which is proven to be
defective.
For warranty service, the product must be sent to an Omnitron
designated facility, at Buyer's expense. Omnitron will pay the
shipping charge to return the product to Buyer's designated
US address using Omnitron's standard shipping method.
Local loop-back (L/LB)
Switch Positions
1
2
3
4
This switch will set the FlexPoint T1/E1 converter in a
loop-back mode on both the fiber and copper connections.
By returning the switch to the normal position the unit will
resume to normal operation.
Cu-Rx
FO-Tx
Cu-Tx
FO-Rx
Loopback Enabled
Remote loop-back (R+L/LB)
This switch will allow the entire fiber segment to be tested
at either of the FlexPoint T1/E1 converters without having
to set switches on both units. When set in this mode the
local unit is switched to a local loop-back mode. The fiber
Tx port will be further encoded to carry a remote loop-back
protocol. This remote loop-back will set the far end
FlexPoint T1/E1 converter to remote loop-back mode and
return a signal to the sending unit. An LED on the local
and remote FlexPoint T1/E1 converters will show a
confirmation that the fiber segment is communicating
properly between devices. By returning the switch to the
normal position it will return to normal operation.
Cu-Rx
FO-Tx
FO-Rx
Cu-Tx
FO-Rx
FO-Tx
Remote Loop Request
Over Fiber
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance of the
equipment by Buyer, Buyer-supplied equipment, Buyer-supplied
interfacing, unauthorized modifications or tampering with
equipment (including removal of equipment cover by personnel
not specifically authorized and certified by Omnitron), or misuse,
or operating outside the environmental specification of the
product (including but not limited to voltage, ambient
temperature, radiation, unusual dust, etc.), or improper site
preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically
disclaims the implied warranties of merchantability and fitness
for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer's sole and
exclusive remedies. Omnitron shall not be liable for any direct,
indirect, special, incidental, or consequential damages, whether
based on contract, tort, or any legal theory.
Form: 040-04470-002D 11/07
Cu-Tx
Cu-Rx

Advertisement

loading

This manual is also suitable for:

T14470/90-04470/90-14470/90-24471/91-04471/91-1 ... Show all