  • Page 1 Proudly Designed and Manufactured in New Zealand By Arrowhead Alarm Products Ltd...
  • Page 2 Area Activation indicators Zone Activity indicators Memory/Event indicator Multi Function Display STAY BYPASS = When Flashing, a Zone has been Manually Bypassed. TROUBLE = When Flashing there is a current System Activation, requiring Resetting. TROUBLE = On Steady the Activation has been Reset, but a Fault still remains.
  • Page 3 Local Edit Mode gives you the ability to adjust some individual keypad functionality. Including:12/24 hour time, Temperature display, KP Tamper, KP software version, KP Address, Calibrate Temperature, Backlight Brightness, Display Contrast and Beeper Tone. To Enter Local Edit Mode, please press then then The display will then read...
  • Page 4 Pressing the Memory button once will bring up any Current System Faults/Alarms On Steady = Current Event Current Event Code (use Current Event Code table) Continuing to press the Memory button will cycle through the Past Events from newest to oldest A Zone light may appear, indicating Flashing = Past Event what Zone the Memory Event relates to.
  • Page 5 = 12V Fuse Failure Alarm (12V Fuse Failure Alarm) = 12V Fuse Failure Restore (12V Fuse Failure Restore) = 24 Hour Zone Bypass Reinstated (24 Hour Zone Bypass Re-Instated) = 24 Hour Zone Bypass (24 Hour Zone BYpass) = 24Hour Zone Alarm (24 Hour Zone Alarm) = 24 Hour Zone Alarm Restore (24 Hour Zone Alarm Restore) = AC Power Fail Alarm (AC Power Fail Alarm) = AC Power Fail Restore (AC Power Fail Restore)
  • Page 6 = Excessive Code Attempts Restore (Excessive CoDe Attempts Restore) = Event Buffer Cleared at Keypad (EVent Buffer Cleared at KeyPad) = Event Buffer Cleared from PC (EVent Buffer Cleared from PC) = Duress Alarm at Keypad (KeyPad Duress Alarm) = Duress Alarm at Keypad Restore (KeyPad Duress Alarm Restore) = Fire Alarm at Keypad (KeyPad Fire Alarm) = Fire Alarm at Keypad Restore (KeyPad Fire Alarm Restore) = Medical Alarm at Keypad (KeyPad Medical Alarm)
  • Page 7 = Telephone Line Failure Restore (TelePHone Line Failure Restore) = Dialler Call Un-answered (PHone Call Not Answered) = No Kiss-Off to Dialler Event (PHone Call Not Kissed-Off ) = Exit Program Mode (PRoGram Mode Exit) = Enter Program Mode ( PRoGram Mode Entry) = Receiver Fail (ReCeiVer Fail) = Receiver Fail Restore (ReCeiVer Fail Restore) = RF Zone Battery Low (RF Zone Battery Low Alarm)
  • Page 8 To Disable Chime press and hold = The display will then read To Enable Chime press and hold = The display will then read ARROWHEAD ALARM PRODUCTS ltd. 344B ROSEDALE Rd ALBANY AUCKLAND Phone: 09 414 0085 Fax: 09 414 0088 www.aap.co.nz V1.2 Page 8/8...