Omega Engineering DMD-480-S2 Series User Manual

Ac powered bridge sensor rs232 interface

Advertisement

Quick Links

PHONE: (203)359-1600 1-800-TC OMEGA FAX:(203)359-7700 info@omega.com
V
e
r
s
i
o
n
2.1
4500.BAS
PROGRAM
USER'S MANUAL
DMD-480-S2 Series
AC POWERED BRIDGESENSOR
RS232 INTERFACE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DMD-480-S2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Omega Engineering DMD-480-S2 Series

  • Page 1 PHONE: (203)359-1600 1-800-TC OMEGA FAX:(203)359-7700 info@omega.com 4500.BAS PROGRAM USER’S MANUAL DMD-480-S2 Series AC POWERED BRIDGESENSOR RS232 INTERFACE...
  • Page 2: Specifications

    D M D - 4 8 0 - S 2 S E R I E S A C P O W E R E D B R I D G E S E N S O R - R S 2 3 2 I N T E R F A C E DMD-480-S2 Series...
  • Page 3 DMD-480-S2 SERIES HOOK-UP (REFER TO FIGURE 1 AND TABLE 1 FOR SCREW TERMINAL DESIGNATION) CONNECT AC TO SCREW TERMINALS 5 AND 6 OF THE DMD-480-S2 SERIES TERMINAL BLOCK. USING A ONE TO ONE DB9 CABLE, CONNECT ONE END TO YOUR COMPUTERS SERIAL PORT, (COM1 OR COM2 ONLY), AND THE OTHER END TO THE DMD-480-S2 SERIES FEMALE DB9 CONNECTOR.
  • Page 4 (XXXXX.BAS). AFTER YOU QUIT THE OPERATION MENU OR TURN OFF THE HOST COMPUTER, ALL SETTINGS WILL RETURN TO THEIR DEFAULT VALUES UNLESS SAVED. DMD-480-S2 SERIES DIP SWITCH SETTINGS SET THE DESIRED ADDRESS FOR EACH UNIT BY SETTING SWITCHES 1-6. BY SETTING THIS ADDRESS, THE UNIT IS GIVEN ITS OWN IDENTITY TO WHICH THE HOST COMPUTER WILL IDENTIFY WITH.
  • Page 5 OPTION 1 [SELECT COMMUNICATIONS PORT]: THIS OPTION ALLOWS THE SELECTION OF EITHER COM1 OR COM2 AS THE COMMUNICATIONS PORT FOR THE DMD-480-S2 SERIES AND THE USERS COMPUTER. COM3 AND COM4 ARE NOT ALLOWED. THE SETTING OF THE COMMUNICATIONS PORT IS ALWAYS NECESSARY FOR PROPER OPERATION OF THE DMD-480-S2 SERIES IN BOTH THE OPERATION AND TEST MODES.
  • Page 6 WILL EXECUTE THE OPERATE MODE IF THE DMD-480-S2 SERIES HAS BEEN SET FOR MODE 0 (SW7 AND SW8 “ON”). OPTION 3 [START TEST MODE]: WILL EXECUTE THE TEST MODE IF THE DMD-480-S2 SERIES HAS BEEN SET FOR MODE 1 OR 3. SETTING THE SCALING EQUATION MODE”...
  • Page 7 D M D - 4 8 0 - S 2 S E R I E S A C P O W E R E D B R I D G E S E N S O R - R S 2 3 2 I N T E R F A C E 1.
  • Page 8 D M D - 4 8 0 - S 2 S E R I E S A C P O W E R E D B R I D G E S E N S O R - R S 2 3 2 I N T E R F A C E VERIFY YOUR RESULTS BY PLACING YOUR SOLUTIONS BACK INTO EQUATIONS A AND B: UNDER OPTION 3 OF THE SETUP MENU, THE COLLECTED DATA...