Omega Engineering WMS-22 User Manual

Current loop wind stations

Advertisement

Quick Links

Manual
fl
Current Loop Wind Stations
WMS-22A Wind Speed indicator
WMS-22 Wind Speed and Direction Indicator
Operator ' s
@
*
em WMS-22A and WMS-22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WMS-22 and is the answer not in the manual?

Questions and answers

Summary of Contents for Omega Engineering WMS-22

  • Page 1 WMS-22A and WMS-22 Current Loop Wind Stations WMS-22A Wind Speed indicator WMS-22 Wind Speed and Direction Indicator Operator ’ s Manual...
  • Page 2: Unpacking Instructions

    Remove the Packing List and verify that you have received all equipment, including the following (quantities in parentheses): WMS-22A or WMS-22 ”. Wind Sensor Transmitter Housing Assembly, with I/O connection terminal strips Operator’ s Manual If you have any questions about the shipment, please call the OMEGA Customer Service Department.
  • Page 3 Servicing USA and Canada: Call OMEGA One Omega Stamford, CT 06907-0047 Telephone: (203) 359-1660 FAX: (203) 359-7700 Sales Service: l-800-826-6342 Customer Service: l-800-622-2378 Engineering Service: l-800-872-9436 TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Servicing Europe: United Kingdom Sales and Distribution Center 25 Swannington Road, Broughton Astley, Leicestershire Telephone: 44 (1455) 285520 The OMEGA Complete Measurement and...
  • Page 4: Physical Description

    2-wire current loops. The WMS-22 wind sensor includes a three-cup anemometer and wind vane. The sensor is ruggedly constructed of UV-resistant ABS plastic and anodized aluminum parts. The cable that connects the pole-mounted wind sensor to the encoder electronics package may be extended up to a total of 250 feet.
  • Page 5: General Description

    3.0 GENERAL DESCRIPTION 3.1 Wind Speed Measurement The WMS-22 wind sensor is designed to be mounted on the end of a supplied with 40 feet of cable for connection to the electronics housing. The anemometer’ s precision ball bearing is protected from the weather and has lifetime lubrication. The counterweight at the end of the wind vane balances the weight of the moving mass over its supporting bearing.
  • Page 6: Operational Checkout

    A typical installation will position the wind sensor approximately 10 meters above the highest obstacle within a 300 meter radius of the mounting locations. Position the WMS-22 sensor on the end of a 314” Schedule 40 pipe. If the pole is metal it should be well grounded diameter TV mast tubing or a electrically to minimize the probability of any lightning damage.
  • Page 7 The WMS-22 normally should not require adjustment of these controls. An exception occurs if for any reason the wind sensor is changed or if the cabling to the wind sensor exceeds 200 feet in length.
  • Page 8 5 I I - l - DC PO W ER SOURC TYPICAL LO PRODUCES OU 10 l o 48 E L Z - W S - 2 2 CURREN OO P W I NDS I O N I CA L W I R I NG W I T H A S I NG L E PO...
  • Page 9 I J I...
  • Page 10: Warranty

    RETURN REQUESTS Direct all warranty and repair requests/inquiries to the OMEGA ENGINEERING Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA ’ S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS).
  • Page 11: Data Acquisition

    Where Do Find Everything Process Measurement and Control? OMEGA...Of Course! TEMPERATURE Thermocouple, RTD Wire: Thermocouple, RTD & Thermistor m Calibrators & Ice Point References m Recorders, Controllers w Infrared Pyrometers PRESSURE/STRAIN FORCE Transducers & Strain Gages B Load Cells & Pressure Gauges B Displacement Transducers w Instrumentation &...