Kenwood RXD-M33 Service Manual page 11

Hide thumbs Also See for RXD-M33:
Table of Contents

Advertisement

RXD-M33/M33MD
QQ
3 7 63 1515 0
When removing the flexible board from the connector,
make a solder bridge in advance, then remove the board.
Be careful not to remove the solder bridge before
inserting the connector. Moreover, take careful
measures against electrostatic destruction. The flexible
board is cut easily. Handle the flexible board with care.
8-3 Precaution during adjustment
1) Perform the adjustment and confirmation marked with "O"
in the order shown in the table when the parts below are
replaced.
1.Temperature compen-
sation offset adjustment
2.Laser power adjustment
3.Traverse adjustment
4.Focus bias adjustment
5.Error rate confirmation
2) In the test mode, perform the adjustment. After
adjustment is completed, cancel the test mode.
3) Perform the adjustment in the order described.
TE
L 13942296513
4) Use the following tools and measurement equipment.
• CD test disc TGYS-1
• Laser power meter
• Oscilloscope (with bandwidth of more than 40 MΩ)
(Calibrate the probe before measurement.)
• Digital voltmeter
• Thermometer
5) Take care that VC and GND (ground) are not connected
on the oscilloscope when two or more signals are
monitored on the oscilloscope. (VC and GND are short-
circuited in this case.)
8-4 Creating the recordable continuous recording
disc
This disc is used for focus bias adjustment and error rate
confirmation. How to create the recordable continuous
recording disc is 3-8.
8-5 Offset Adjustment
No.
Key
1 Volume/multi-control Select [TEMP ADJU]
2 PLAY
3 Volume/multi-control Input "yy" with present temp..
4 PLAY
www
.
CIRCUIT DESCRIPTION
Pick-up
Flexible board
Laser tap
Optical
BD board
pick-up
IC7
D3
IC1,IC2,IC6
X
O
O
O
O
X
O
O
X
O
O
X
O
O
X
Display/Function
[TEMP=xx (yy)]
(xx=compensation data, yy=setting temperature)
[TEMP=✽✽SA]
[TEMP ADJU] in writing data
x
ao
y
i
8
8-6 Laser Power Check and Adjustment
Laser power setting in playback and recording modes.
Preparation
1. Remove the MD mechanism from the unit.
2. Connect the digital voltmeter to TP1 and TP2 on X33
pcb.
3. Remove the top plate from traverse unit.
4. Remove the magnetic head.
5. Remount the MD mechanism to the unit
Objective lens of
optical pick up
O
O
O
1. Laser Power Adjustment
O
No.
Key
O
1 Volume/
multi-control
2
PLAY
Q Q
3
6 7
1 3
3 EJECT
4 4/¢
5 Volume/
multi-control Adjust "xx" so that the power meter shows 0.9mW.
6 PLAY
7 Volume/
multi-control
8 PLAY
Start from No.2 if readjust.
2. Laser Power Check
No.
1 Volume/multi-control [LDPWR CHEC]
2 PLAY
3 PLAY
(optical pick-up label)
8-7 EF Balance(Traverse Adjustment)
Connection :
u163
X33
ADJUSTMENT
.
2 9
9 4
2 8
Laser
power meter
Digital
voltmeter
X33
ADJUSTMENT
TP2
TP1
Display/Function
[LDPWR ADJU]
Load recordable disc
Load the disc and lazer on
a 0.9mW) $xx] read power
(xx=power value)
1 5
0 5
8
2 9
9 4
Unload the disc and laser on
Move the pickup to check the laser power with
laser power meter sensor
a 7.0mW) $xx] writing power
Adjust "xx" so that the power meter shows 7.0mW.
This adjustment should be carried out in 15 secs.
Laser power off
Display shows [LDPWR ADJU] after [LDPWR<$xx]
to save the data in E2PROM
Key
Display/Function
c 0.9mW) $xx]
(xx=0.85 to 0.95mW)
c 7.0mW) $xx]
Laser power meter: 7.0±1.0mW✽
VOM:optical pickup indication value ±10%✽
KMS
260B
27x40
B0825
In this case, lop = 82.5 mA
lop(mA) = Reading of digital voltmeter(mV)/1(Ω)
m
Oscilloscope
co
+
TE1
-
VC
V: 0.5V/div H: 10ms/div
INPUT: DC mode
9 9
+
-
2 8
9 9
11