INFORMATION TO USER CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SEERIVCE PERSONEL. This symbol is intended to alert the user to the presence of un‐insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. This symbol is intended to alert the user to the presence of important operating ...
NM‐IP3500 1. FEATURES Camera • Indoor/Outdoor Fixed Dome IP Camera (Vandal Proof) • High Quality Compression in real time streaming • Sony 1/3” Super HAD CCD & High Quality SS‐HQ1 Full Kit Chip Set Sony 1/3" Vertical Double Density Color CCD (Optional) • True Day / Night (ICR) and WDR (Optional) • Improvement of color rolling suppression Streaming • Dual streaming mode (such as different codec/resolution/bit rate and so on.) • De‐interlacing on DSP • Burnt‐in text supported • Unicast/Multicast supported Video/Audio • Video compression: H.264/MPEG/MJPEG, 25/30FPS@D1(PAL/NTSC) • Audio compression: G.711(µLaw, aLaw)/PCM • Analog video out for external monitors • Video Motion Detection supported • 2‐way mono audio supported Network • RTSP/ HTTP protocol supported • 10/100 Base‐T Ethernet ...
NM‐IP3500 2. PACKAGE CONTENTS Unpack carefully and handle the equipment with care. The packaging contains: Camera DC power adaptor Extension cable (for LAN and power connector) 11 Pin terminal block Hex wrench driver Screws and Anchor blocks Installation Template Video BNC Cable Quick Installation Guide Surface Cushion (for protection against dust) The above contents are subject to change without prior notice. Note 6 ...
NM‐IP3500 3. PART NAMES 3.1.Internal View ④ ③ ② ① * Models herein and their appearance are subject to change without any prior ⑤ ⑥ notice. 11 pin terminal block for D/I, D/O, audio, and serial communication 11 pin terminal block for D/I, D/O, Audio in /Out and serial communication. Refer to the section “5.1.Connectors” for more specific information. Reset Reset switch is used for restarting or resetting the camera to Factory Default (FD). Refer to the section “6.3. Reset” for more specific information. Micro SD Card Socket It is a memory card slot for external storage. Extension cable Socket It is a socket for LAN and power connector. LAN Connector (Ethernet) This is a RJ45 LAN connector for 10/100 Base‐T Ethernet. This socket can also be used to power the camera via PoE (Optional). Power Adaptor Connector (DC 12V) The camera needs a DC 12V 1A adapter for power supply. ...
NM‐IP3500 4. INSTALLATION Connect the LAN cable, power supply cable, and the video loop out cable with the camera. Place the installation template on the 2) ceiling. Drill three holes on the template and 3) insert anchor blocks into the holes. Fasten the camera with screws. Put the dome cover on the main 4) body of the camera. Make sure the main body and the cover fit each other ...
NM‐IP3500 The camera may fall off the ceiling even after the proper installation and mounting. To prevent any accident, make sure the ceiling is firm and stable Caution enough to support the camera. If any reinforcement is needed, consult with ...
NM‐IP3500 4.2. Manual adjustment for 3-axis movements After installation, make a manual adjustment on the inner liner. Perform 3‐axis movements manually by turning the inner liner to different directions as above, and check if it moves properly. 4.3.
NM‐IP3500 5. CONNECTIONS 5.1.Connectors Audio In / Out The camera has a mono audio input and a mono audio output. As the output power for the audio is low, amplifier speaker is needed (Do not use a headphone or earphone directly to the camera). Aout Amp Speaker Sensor (DI) connection The camera provides 1 channel D/I. It can be connected to either a voltage type sensor or a relay type sensor as the following figures. It can be selected by software. Input voltage range: 0 VDC minimum to 24 VDC maximum Input voltage threshold: 1 V Do not exceed the maximum input voltage or relay rate. Caution 11 ...
Page 12
NM‐IP3500 Internal +5V Internal Output of Output of Sensor Sensor DI DI ‐ ‐ COM + ‐ COM Relay Type Voltage Type Alarm (DO) connection Only the relay type is supported. Relay Rating: Max 24VAC 500mA or 12VDC 1A Do not exceed the maximum relay rating. Caution Internal Device Relay Type Video Out The camera provides 1 video loop out. Video GND Black White ...
Page 13
NM‐IP3500 RS‐485 The RS‐485 serial port consists of TRX+(RX+) and TRX‐(RX‐) as following the following image. 485 Device RS‐485 Connection 13 ...
NM‐IP3500 6. CONFIGURATION 6.1.Set up network environment The default IP address of your IP device is 192.168.XXX.XXX. You can find the available IP address from the MAC address of your device. Please make sure the device and your PC are on the same network segment before running the installation. If the network segment between your PC and the device is different, change your PC’s settings as below. IP address : 192.168.xxx.xxx Subnet mask: 255.255.0.0 6.2. View video on web page View the live video on a web page using your IP device and its IP address. You can use the IPAdminTool or enter the IP address on the web page. ...
Page 15
NM‐IP3500 To use the IPAdminTool and view the live video on a web page: 1. Start IPAdminTool. Names and info of currently activated devices appear as a list. 2. Right‐click on the desired device and select Web view. 3. Select Continue to this website on the Security Certificate Alert page. (The explanation and captured images at this manual are mainly on the basis of Internet Explorer 7.0) 4. Click pop‐up blocked and install the ActiveX control by clicking the Install button. You need to install the ActiveX for displaying the images. 15 ...
Page 16
NM‐IP3500 5. Wait for a few seconds while the web page loads. Then the live video is displayed on the main page of the web browser. 6. If the live video is not displayed and “Can not Create XMLDOMDocument Install MSXML4.0” message is shown as below, please download and Install from the link below. http://www.microsoft.com/downloads/details.aspx?familyid=3144B72B‐B4F2‐46DA‐ B4B6‐C5D7485F2B42&displaylang=en (VCA Library requires MS XML 4.0 library which is an xml parser made by Microsoft.) ...
NM‐IP3500 6.2.2.View video using IP address View the live video on a web page using your IP device and its IP address. To have the correct IP address ready and use it on a web page: 1. Convert a MAC address to an IP address or check the IP address on the IPAdminTool. (The MAC address is attached on the side or bottom of the device.) MAC address = 00‐13‐23‐01‐14‐B1 → IP address = 192.168.20.177 the Hexadecimal number to Decimal number. 2. Open a web browser and enter the IP address of the device. 3. Click Continue to this website on the Security Certificate Alert page. 4. Click pop‐up blocked and install the ActiveX control as below. You need to install the ActiveX for displaying the images. 5. Wait for a few seconds while the web page loads. The live video is displayed. 6.3. Reset 1. While the device is in use, press and hold the Reset button. 2. Release the Reset button after 3 seconds. 3. Wait for the system to reboot. 6.4. Factory Default 1. Disconnect the power supply from the device. 2.
NM‐IP3500 VCA (Video Content Analysis) VCA Presence (Included as Standard) High Performance Advanced Tracking Algorithm, Low False Alarm Rate Easy to Use Intuitive Web Browser Interface Detection Zones Multi‐segment Polygons and Lines On‐screen Display Real‐time Display of Tracking Data and Events Stream or Analog video out Burnt‐in Annotation (※Analog video out support can vary depending on the device model and hardware version and the firmware version) VCA Surveillance (Optional) Camera Tampering, Direction, Stopping, Loitering, Entering, Detection Behavior Exiting, Appear, and Disappear Filters 3D Behavior Perspective Corrected Size and Speed Filters Statistics Counting Functions and Other Statistics Meta Data Binary XML Format Image Stabilization (Optional) Electronic Stabilization Removes Camera Sway ...
NM‐IP3500 APPENDIX (B): POWER OVER ETHERNET The Power over Ethernet(PoE) is designed to extract power from a conventional twisted pair Category 5 Ethernet cable, conforming to the IEEE 802.3af Power‐over‐Ethernet (PoE) standard. IEEE 802.3af allows for two power options for Category 5 cables. The PoE module signature and control circuit provides the PoE compatibility signature and power classification required by the Power Sourcing Equipment (PSE) before applying up to 15W power to the port. The high efficiency DC/DC converter operates over a wide input voltage range and provides a regulated low ripple and low noise output. The DC/DC converter also has built‐in overload and short‐circuit output protection. ...