Attwood Tsunami 4606 Installation Instructions

Attwood tsunami bilge pump installation instructions

Advertisement

Quick Links

3
Tsunami Bilge Pump
4606, 4608, 4612, 4613 Series

Installation Instructions

SAVE THESE INSTRUCTIONS
Form Number 69390 Rev. A

WARNING

Read all instructions carefully before installing and using this product.
To prevent personal injury, disconnect the power source when installing
or servicing this product. Always remove the boat from the water before
using 120V AC power tools.
DO NOT use pump to remove gasoline, oil or other flammable liquids.
Always use the fuse amperage rating specified for your pump model.
Failure to do so could result in serious personal injury or fire hazards.
Attwood bilge pumps are designed to exhaust STANDING WATER
ONLY. They are not intended to prevent rapid accumulation of
on-board water due to rough weather, hull damage, and/or other
unsafe navigational conditions.
Refer to Specification Chart to be sure you have selected the
proper pump:
12-Volt Models
ABYC Specifications
(GPH = Gal. Per Hour)
0 ft.
Part
Outlet
Head
Num./
Hose Motor Amp GPH/
Series
I.D.
Cart.
Fuse amps
4606/600 3/4"
4620 2.5A 500/1.5 400/ 1.5 250/1.5 1705/1.3 1250/1.3 8'/27
4608/800 3/4"
4622 4A
800/3.0 660/3.0 510/3.0 2840/2.5 2274/2.5 14'/33
4612/1200 1-1/8" 4624 5A
1200/3.5 900/3.5 700/3.5 4169/3.0 3000/3.0 11' 7"/28
24-Volt Models
ABYC Specifications
(GPH = Gal. Per Hour)
0 ft.
Part
Head
Num.
Amp GPH/
Series
Fuse amps
4609/800 3/4"
4623 2A
800/1.3 660/1.3 500/1.3 2842/1.1 2160/1.1 14'/31
4613/1200 1-1/8" 4625 2A
1200/1.5 900/1.5 725/1.5 4100/1.3 3100/1.3 11'/28

MATERIALS REQUIRED

• Three #8 stainless fasteners, suitable length for mounting surface
• Cordless drill and 1/8" (3mm) bit
• Hose clamps (Attwood # 9185, 2 per connection)
• Mounting pad: marine plywood, fiberglass cloth and resin
• Manual (# 7615A) or automatic float switch (#4201 or 4202)
• Fuel-resistant, reinforced smooth bore outlet hose

INSTALLATION LOCATION

1. Position pump in the lowest accessible part of the bilge. On
sailboats, location should be centered over keel. (Figure 1)
®
ISO Specifications
@13.6 VDC
@12 VDC
(LPH = Liters Per Hour)
3.3 ft
6.7 ft
0kPa
10kPa
Head
Head
Head
Head
GPH/
GPH/
LPH/
LPH/
amps
amps
amps
amps
ISO Specifications
@24.0 VDC
@24.0 VDC
(LPH = Liters Per Hour)
3.3 ft
6.7 ft
0kPa
10kPa
Head
Head
Head
Head
GPH/
GPH/
LPH/
LPH/
amps
amps
amps
amps
Figure 1
Base Strainer
10-03
2. Do not mount pump directly to hull. Attach base strainer to a
marine plywood mounting pad that is fiberglassed to the hull.

HOSE CONNECTION INSTRUCTIONS

IMPORTANT: To prevent airlock, hose must rise continually upward
to the thru-hull connector with no dips or sharp bends. Support hose
if necessary.
1. Orient pump outlet for a direct, unobstructed hose path.
2. Secure all connections with hose clamps.
3. If no thru-hull connector exists, install at 12" min. (25mm) above
water line. Apply marine sealant around thru-hull flanges on
interior and exterior of hull.

PUMP MOUNTING INSTRUCTIONS

1. To access mounting holes, remove base strainer. Hold housing with
one hand, depress locking tab with other. Twist counter-clockwise
and remove pump housing from base. It is not necessary to remove
motor cartridge for installation. (Figure 2)
Figure 2
Max
Head
(ft.@13.6v/
kPa@12v)
Pump Housing
(3) #8 Fasteners
Max
Base Strainer
Head
(ft.@24v/
kPa@24v)
1/8" Pilot Holes
2. Use base as template to mark 3 mounting holes in mounting pad.
CAUTION: Do not drill through hull. Before drilling be sure mounted
pump will be correctly positioned with pump nozzle pointing toward
thru-hull connector. (Figure 1)
3. Remove base. Drill three 1/8" (3mm) pilot holes at marked locations.
4. Replace base. Attach with #8 stainless steel fasteners.
5. Re-attach pump to base. Insert into base, twist clockwise until tab
snaps in and prevents turning. (Figure 2)

WIRING INSTRUCTIONS

Make all wire connections above the highest water level. Use marine
grade wire connectors only. Waterproof all connections with suitable
materials. (Figure 3)
NOTE: Failure to make waterproof connections and fuse pump properly
will void the product warranty.
Thru-Hull Connector
Hose & Clamp
Suitable Mounting Pad
Lock
Unlock
Lock
Motor Cartridge Replacement
Press Tab
To Unlock
12" min. Above
Water Line
Hose MUST Rise
Upward with NO DIP
Unlock
Motor
Cartridge
Tab

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tsunami 4606 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Attwood Tsunami 4606

  • Page 1: Installation Instructions

    Always use the fuse amperage rating specified for your pump model. Failure to do so could result in serious personal injury or fire hazards. Attwood bilge pumps are designed to exhaust STANDING WATER ONLY. They are not intended to prevent rapid accumulation of on-board water due to rough weather, hull damage, and/or other unsafe navigational conditions.
  • Page 2 4. Insert cartridge into housing. Twist clockwise until you hear tab snap up into slot. (Figure 2) ATTWOOD BILGE PUMPS LIMITED WARRANTY This Attwood Bilge Pump carries a three (3) year warranty. See product catalog or www.attwoodmarine.com for details. ©2003 Attwood Corporation...

This manual is also suitable for:

Tsunami 4608Tsunami 4612Tsunami 4613Tsunami 69390Tsunami 4606 seriesTsunami 4608 series ... Show all

Table of Contents