FPSG & FPEG 700-780-900-1100
Installation Instructions into Wood or Block Alcoves
Warmington Gas Cowl
( Top Venting can also be
through S/S Flashing .
See Flashing Detail in Spec )
Installation to Comply with NZS 5261 / 5262:2003
Keep these Instructions for further reference......Ensure that you have the correct and current installation details for the Broady's Fire
The Broady's unit is to be Installed by a Certified Broady's Installer or an Approved NZHHA Installation Technician .
A Certified Craftsman Gas Fitter and Certified Electrician are required to run Power and Gas Supplies as required to the unit and any Commissioning as
part of the Installation process . The heater must be Installed according to these Instructions and in Compliance with all relevant building , gas fitting,
Read all the instructions carefully before commencing the Installation. Failure to follow these instructions may result in a fire hazard and void the warranty
1
Due to continued product improvement, Broady's reserves the right to change product specifications without prior notification.
GAS OPEN FIRE'S
S/S Flashing
Gas Firebox
Hearth
Fire, flue system and instructions to comply with NZS 5261/5262 :2003
See www.homeheat.co.nz/members for a Certified NZHHA SFAIT Installer in your area .
electrical and other statutory regulations.
All Dimension are in mm.............Copyright ©
Installation
IMPORTANT
14 December 2010
Warm Air Outlet
Vent
Warmington Flue System
Timber Framing
Cool Air "Caitec
Vents" Inlet Vent

Advertisement

Table of Contents
loading

Summary of Contents for Broadys Fp 700

  • Page 1 14 December 2010 FPSG & FPEG 700-780-900-1100 GAS OPEN FIRE’S Installation Instructions into Wood or Block Alcoves Warmington Gas Cowl S/S Flashing Warm Air Outlet Vent ( Top Venting can also be through S/S Flashing . See Flashing Detail in Spec ) Warmington Flue System Timber Framing Gas Firebox...
  • Page 2 Ensure that the front face of Heat Cell Clearance alcove is left open and unframed to enable Installation of the Firebox. The Chimney Chase is left unlined for Installa- tion of the Flue. Construct Plinth only, to required height. * Stage 2: Install Procedure by Certified “Broadys Installer”only. Fit Fire to Plinth.(Ensure Gas Supply Line is fed through R.H. Side of Firebox.) Fit Flue System.
  • Page 3 14 December 2010 FIREBOX DIMENSION Firebox 1100 Firebox Width 1110 Firebox Height Firebox Depth Flange Width 1000 1200 Flange Height Insulation Kit Width 1195 Insulation Kit Height Insulation Kit Depth Centre of Flue Flue Flue Liner Fascia Width 1060 1260 Fascia Height Fascia Section Heat Output...
  • Page 4: Important Notes

    GAS SPECIFICATIONS Tested to : AS 4558 NOTE : All Test Pressures are tested by an Independent Test Lab * Inlet Pressure not to exceed 4.0KPa MODLE Fp 700 Fp 780 Fp 900 Fp 1100 Nominal Pressure kPa 2.75 kPa 2.75 kPa...
  • Page 5 14 December 2010 TIMBER FRAMING & TRIM OUT DETAILS Firebox 1100 Heat cell Clearance Width 1010 1210 Heat Cell Clearance Height Heat Cell Clearance Depth Hearth Width 1100 1180 1300 1500 Hearth Projection Chimney Chase Clearance Window Height Window Width 1010 1210 COMMON ALCOVE FRAMED...
  • Page 6 14 December 2010 Note: TIMBER : PLAN, FRONT ELEVATION & CROSS SECTION Centre Line of Flue is `NOT’ in Cen- tre of Alcove Firebox 1100 Hearth Width 1100 1180 1300 1500 Hearth Projection Alcove Width 1010 1210 Alcove Depth Centre of Flue Chimney Chase Clearance BLOCK : PLAN, FRONT ELEVATION &...
  • Page 7 14 December 2010 BLOCK ALCOVE & TRIM OUT DETAILS Firebox 1100 Heat cell Clearance Width 1210 1210 1210 Alcove Clearance Height 2400 2400 2400 2400 Note: Alcove Clearance Depth Window Height Centre Line of Flue is `NOT’ in Centre of the Window Width 1000 1200...
  • Page 8 14 December 2010 FLUE DETAILS DIMENSIONS Minimum Flue Height Flue Height 3600 Measured From Top of Adaptor B + 3600 Flue details 1100 Cowl Flue Diameter Liner Diameter Spacer 200/250 200/250 250/300 250/300 Bottom Spacer 200/250 200/250 250/300 250/300 NOTE: Ensure that a Standard Tested Broady’s Flue System is used on the Broady’s Fires.
  • Page 9 14 December 2010 FLUE PENETRATION Vented through Alcove (Single FLUE PENETRATION Vented through Alcove (Double lined Flue System) lined Flue System) Note : FLUE PENETRATION Vented through Top Flashing External Requirements Refer to AS/NZS2918:2001 4.9.1/ NZS5261/5262:2003 Install Flue system to AS/NZS2918:2001/ 5261/5262:2003 When using a rubber or Bitumen flashing (Butynol, Dectite) an Additional Flue pipe Baffle is required.
  • Page 10 14 December 2010 CHIMNEY CHASE FLASHING DETAILS Note: Flashing Spigot height is determined by the Insulation that is fitted under the Flashing … See Details at bottom of page. “CHIMNEY CHASE FLASHING” AND “AIR VENTILATION” OPTIONS : VENTING THROUGH CHIMNEY CHASE “No Insulation “Insulation under under flashing”...
  • Page 11 14 December 2010 FLUE HEIGHT MINIMUM DETAILS The Flue exit is to comply to ASNZS 2918 : 2001 3D View FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X – Singled Lined Flue System Option Y – Double Lined Flue System Due to continued product improvement, Broady’s reserves the right to change product specifications without prior notification.
  • Page 12: Hearth Clearances

    14 December 2010 COMBUSTIBLE MANTLE CLEARANCES HEARTH CLEARANCES Note: For Combustible Floors Minimum Hearth of 300mm (A) must be maintained at any given height. Due to continued product improvement, Broady’s reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 13 14 December 2010 Fp SG & Fp EG Range: Gas Convection Fireplaces TO THE INSTALLER / GAS FITTER and ELECTRICIAN NOTES : • Service annually or more if required. • Custom built to clients requirements to NZS5261/5262:2003 Clause B2.3 • The Appliance and Flue System must be installed in accordance with NZS5261/5262:2003 and the appropriate Building codes.
  • Page 14: Bottom Row

    Number of Coals per Row Number of Rows Model Bottom Bottom Total Fp 700 Fp 780 Fp 900 Fp 1100 Due to continued product improvement, Broady’s reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 15: To Shut Down

    14 December 2010 FASCIA KIT (Black or Stainless Steel) Locate the three self-tapping screws provided into the under-side of the top ledge of the firebox Remove the backing tape from the adhesive Velcro pads at the bottom of each fascia side Offer the fascia into position locating the three screws into their associated slots - tighten screws Apply firm pressure to the bottom edges to bond the Velcro tape The fascia may be removed at any time by loosening the screws and parting the Velcro...
  • Page 16 14 December 2010 ADJUSTMENT OF HI—LOW PRESSURE (Manual ONLY) (Only to be Adjusted by Gasfitter) Adjustment of High & Low Settings Must be Carried out by a Certified Gas Fitter Only . Note* Control Valves are Factory Set but may require adjustment onsite . Turn Appliance Off &...
  • Page 17 *Lighting your gas fire using electronic or remote ignition systems may vary as per manufacturer instructions Broadys recommend annual servicing of your gas fire by an approved Broadys dealer Gas Fitter. External surfaces should be dusted with a damp, lint-free cloth when the fire is cold.
  • Page 18: Flame Operation

    14 December 2010 OPERATION OF YOUR FpE.G GAS BURNER IGNITER ONLY FOR MANUAL OPERATION OF YOUR FpEG DECORATIVE FIRE AS SHOWEN FROM THE FRONT OF THE BURNER. This Control Panel is Located on the Bottom Left Hand Side of your decorative Gas Fire. Press and Release the Power Button.
  • Page 19: Fan Operation

    14 December 2010 FAN OPERATION This Decorative Gas Fire has a 3 Speed Fan and its operated independent from the Main Burner. This is done by pressing and releasing the fan + or – button will Increase or Decrease the Fan Speed.
  • Page 20 14 December 2010 PROCEDURE FOR THE TEST AND COMISSIONING OF YOUR DECORATIVE FIRE. Ensure Gas Supply and the Power Supply (caution 240V) to the Unit. Refer to Data Plate on this Specification for settings. The Data Plate is attached to the under carriage of •...
  • Page 21 14 December 2010 DIAGRAM B ( SHOWING CONTROL VALVE WITH TEST POINTS AND ADJUSTING SCREW ). DIAGRAM B Modulator Harness Connections Modulator Harness Connections “Nut A” “Screw B” • After checking the pressure, turn the unit off, remove Manometer from the Test Point and Tighten the Test Point Screw.
  • Page 22 14 December 2010 REMOTE IGNITION FpEG GAS FIRE WIRING DIAGRAM Modulator Harness Connections Due to continued product improvement, Broady’s reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...