Installation Diagram Of Indoor Unit And Outdoor Unit - Samsung ASH180UE Service Manual

Table of Contents

Advertisement

3-2-2 Installation diagram of indoor unit and outdoor unit

GAS LEAK TEST
Indoor unit check
points
Outdoor unit
check points
* Check for gas leak from the flare nut
connections with leak detector.
Coolant adjustment pro c e d u re
C l a s s
At installation
C o n n e c t i o n
A i r- p u rg e
C o o l a n t
pipe lengh
m e t h o d
a d j u s t m e n t
u n n e c e s s a ry
5m max
Refer to the
detailed
a i r- p u rg e
p ro c e d u re .
Add "A"g of
c o o l a n t
5 ~ 1 0 m
<R-22> for
e v e ry 1m.
(Refer to
the detailed
c o o l a n t
c h a rg e
p ro c e d u re . )
Samsung Electronics
Slope of drain hose
Avoid up
slopes
250mm
m i n i m u m
5 6
4
10
At installation
Air purg e
R e f r i g e r a n t
m e t h o d
q u a n t i t y
See table
P u rge air
r i g h t .
using
a vacuum
pump or an
a d d i t i o n a l
Add "A"g of
c o o l a n t
c o o l a n t
c y l i n d e r.
<R-22> for
e v e ry 1m.
(Refer to
the detailed
c o o l a n t
c h a rg e
p ro c e d u re . )
* Piping may be laid to the rear, left, right or down.
Right
Rear
Down
Left rear
Insulation of pipe connection area
* Perform gas leakage test first, and insulate the pipe
connection area.
Use an insulation tube for insulation as shown in figure.
The insulation
tube shall be
properly finished
not to allow
any gap.
Hole dimension of bolts for the outdoor unit
Fix firmly if installed in an area affected by typhoons.
Coolant adjustment pro c e d u re
Outer diameter
ø6.35mm
ø12.7mm
ø15.8mm
Tighten the flare nut by hand first, and tighten firmly with a spanner
C o o l a n t - q u a n t i t y
M o d e l
Coolant quantity
A S H 1 8 0 U E
1 3 0 0 g
A S H 1 8 1 U E
A S H - 2 4 1 7 E R
1 7 5 0 g
A S H - 1 8 0 8 D R
1 6 7 0 g
For more information refer to the Installation Manual.
350mm or more
Insulation
tube
Vinyl tape
(purchase locally)
Remote control
Remote control holder
582
Fixing torque
Final torque
160kg . cm
200kg . cm
500kg . cm
550kg . cm
700kg . cm
750kg . cm
R e m a r k
Self refrigerant is included with shipment.
Self refrigerant is included with shipment.
Self refrigerant is included with shipment.
Left
ø12
3-5