WARNING - To reduce the risk of burns or ignition of clothing by reaching across burners, the downdraft remote control MUST
be mounted in the countertop - at least 4" from the burners. See "INSTALL COOKTOP" section on page 8.
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. Do not install this product with the activating switch directly
behind a burner or element. Minimum distance between the
switch and the edge of the burner should be 4 inches.
9. Loose-fitting or hanging clothing should never be worn when
operating this appliance. They may be ignited by burners/
elements on cooktop.
10. Children should not be left alone or unattended in the area
where this appliance is in use.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
Call 1-800-667-8721 anywhere in the US and Canada
BLOWER
30"
500 cfm Interior
36"
500 cfm Interior
48"
500 cfm Interior
30"
Models 331H, 332H, 335, or 336 Exterior (purchase separately)
36"
Models 331H, 332H, 335, or 336 Exterior (purchase separately)
48"
Models 331H, 332H, 335, or 336 Exterior (purchase separately)
::
com
.
at
rangehoods
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
a
FOLLOWING
:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immedi
ately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
- a violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
a
Based on "Kitchen Firesafety Tips" published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Clean filters and grease-laden surfaces frequently.
4. Do not repair or replace any part of this appliance unless
specifically recommended in this manual. All other servicing
should be done by a qualified technician.
5. Please read specification label on product for further informa-
tion and requirements.
Model RMDDRBK Remote Up/Down
Control sold separately.
INSTALLER:
Save this manual for Electrical
Inspector and Homeowner to use.
-
www.rangehoods.com
Downdraft Ventilators
!
NOTE:
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Rangemaster RMDD3004

  • Page 1 Call 1-800-667-8721 anywhere in the US and Canada www.rangehoods.com Downdraft Ventilators rangehoods Page 1 MODEL WIDTH BLOWER RMDD3004 30" 500 cfm Interior RMDD3604 36" 500 cfm Interior RMDD4804 48" 500 cfm Interior RMDD3004EX 30" Models 331H, 332H, 335, or 336 Exterior (purchase separately) RMDD3604EX 36"...
  • Page 2: Take Measurements

    1. Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. Mod- els RMDD3004 & RMDD3004EX will fit in most 30" wide cabinets. Models RMDD3604 & RMDD3604EX will fit in most 36" wide cabinets. Models RMDD4804 & RMDD4804EX will fit in most 48"...
  • Page 3 Downdraft Ventilators Page 3 TAKE MEASUREMENTS (CONTINUED) Interior Blower Installation Exterior Blower Installation SIDE VIEW SIDE VIEW OF DOWNDRAFT OF DOWNDRAFT PLAN THE DUCTWORK Interior Blower Installation Exterior Blower Installation LEFT LEFT 1. The interior 1. The interior DISCHARGE DISCHARGE downdraft blower downdraft blower system is designed...
  • Page 4: Blower Installation

    Downdraft Ventilators Page 4 PLAN THE CABINET CUTOUTS LEFT SIDE Blower Installation DISCHARGE ( 1 9 " CAUTION: " F O E X T BEFORE CUTTING HOLE IN E R I B L O CABINET FOR DUCTWORK, check for interference with floor joists, wall studs, electrical CENTER LINE CENTER...
  • Page 5 IMPORTANT - LOCATION OF ELECTRICAL OUTLET: IMPORTANT - LOCATION OF ELECTRICAL OUTLET: If Model RMDD3004 is being installed in a 30" wide If Model RMDD3004EX is being installed in a 30" wide cabinet... cabinet...
  • Page 6 Downdraft Ventilators Page 6 CUT COUNTERTOP OPENING All Units 1. Lay out and cut the cooktop cut-out far enough FORWARD so downdraft will fit behind it. 2. Set cooktop in place and slide it as far forward as possible. Center and square it with edges of countertop. 3.
  • Page 7: Mount The Unit

    Downdraft Ventilators Page 7 MOUNT THE UNIT MOUNTING SCREWS All Units LEVELING BRACKET - FLANGE FACING OUT 1. Set downdraft into opening. Extend leveling brackets to floor of cabinet so downdraft sits straight. (Note: Leveling brackets can be removed and re-attached in other positions. Bottom flange may have to face inward in tight cabinet installations.) 2.
  • Page 8 Downdraft Ventilators Page 8 INSTALL ELECTRICAL WIRING Interior Blower Installation Exterior Blower Installation CAUTION: All electrical wiring should be done CAUTION: All electrical wiring should be done by a qualified person(s) in accordance with all by a qualified person(s) in accordance with all applicable codes and standards.
  • Page 9 Downdraft Ventilators Page 9 REMOTE UP/DOWN CONTROL INSTALLATION (OPTIONAL) All Units When to use the Remote UP/DOWN Control The Remote UP/DOWN Control should be used when your cooktop has a burner that is within 4 inches of the UP/DOWN Button on the downdraft chimney. The Remote UP/DOWN Control can be used for convenient UP/ DOWN operation of the downdraft chimney (even when a burner is more than 4 inches from the UP/DOWN Button of the downdraft...
  • Page 10: Warranty

    Downdraft Ventilators Page 12 WARRANTY SERVICE PARTS BROAN ONE YEAR LIMITED WARRANTY WIDTH WIDTH WIDTH DESCRIPTION Broan warrants to the original consumer purchaser of its products that such products will be free from defects 97015987 97015988 97015989 TOP COVER in materials or workmanship for a period of one year 99140195 99140195 99140195...
  • Page 11 Downdraft Ventilators Page 13 SERVICE PARTS accessories rangehoods Broan at kitchen is a division of...

This manual is also suitable for:

Rmdd3604Rmdd4804Rmdd3004exRmdd3604exRmdd4804ex

Table of Contents