Survivor 12-CSS Installation & Operation Manual

Camp stove

Advertisement

Quick Links

 
 
Please read this entire manual before installation and use of this wood fuel‐ burning 
appliance.  Keep children, furniture, fixtures and all combustibles away from  
 
Failure to follow these instructions can result in property damage, bodily injury  
or even death.  For your safety and protection, follow the instructions  
THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. 
CONSULT THE OWNER'S MANUAL FOR FURTHER INFORMATION. IT IS AGAINST FEDERAL 
REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE 
MADE IN USA 
Manufactured By:   England's Stove Works, Inc.    PO Box 206   Monroe, VA  24574
INSTALLATION & OPERATION MANUAL 
MODEL NUMBERS: 
 
 
any heating appliance. 
SAVE THESE INSTRUCTIONS
SAFETY NOTICE 
outlined in this manual.
OPERATING INSTRUCTIONS IN THE OWNER'S MANUAL. 
 
12‐CSS 
12‐CSM 
"BLACKBEAR" 
12‐CSL 
CAUTION 
"CUB" 
"GRIZZLY" 
REV. 3/2016 
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 12-CSS and is the answer not in the manual?

Questions and answers

Summary of Contents for Survivor 12-CSS

  • Page 1     INSTALLATION & OPERATION MANUAL  MODEL NUMBERS:  12‐CSS  “CUB”    12‐CSM  “BLACKBEAR”    12‐CSL  “GRIZZLY”      CAUTION  Please read this entire manual before installation and use of this wood fuel‐ burning  appliance.  Keep children, furniture, fixtures and all combustibles away from   any heating appliance.    SAVE THESE INSTRUCTIONS SAFETY NOTICE  Failure to follow these instructions can result in property damage, bodily injury   or even death.  For your safety and protection, follow the instructions   outlined in this manual. THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION.  CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION. IT IS AGAINST FEDERAL  REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE  OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL.  REV. 3/2016  MADE IN USA  Manufactured By:   England’s Stove Works, Inc.    PO Box 206   Monroe, VA  24574  ...
  • Page 2 IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT, DO  NOT RETURN IT TO THE DEALER.    CONTACT TECHNICAL SUPPORT @ 1‐800‐245‐6489      Retain for your files     Model Number Date of Purchase Serial Number Have this information on hand if you phone the factory or your dealer   regarding this product.      CAUTION       Keep children away.     Supervise children in the same vicinity as this appliance.      • Alert children and adults to the hazards of high temperatures.    • Do NOT operate with protective barriers open or removed.    •  Hot while in operation!  Keep clothing, furniture      and other combustibles away.  Contact may cause skin burns!     Do NOT over‐fire your unit.    ...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS      Introduction    Welcome! ….............. 4  •   Assembly Info    Assembly ………………….......... 5  • Floor Protection ............ 6  • Clearances ………............ 6  •   Installation    Installation Information .......... 7  •   Operation    Before Your First Fire ........... 8  • Starting Your Fire …………………………………..... 9  • Cooking  .............. 10  •   Maintenance    Ash Removal  …….………………………………....... 10  • Other Maintenance ............. 10  •   Warranty    Warranty Details ............ 12 ...
  • Page 4 INTRODUCTION Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works was started, and is still owned by, a family that believes strongly in a "Do It Yourself" spirit – that’s one reason you found this product at your favorite “Do It Yourself” store. We intentionally design and build our stoves so that any owner can maintain his or her unit with basic tools, and we're always more than happy to show you how to do the job as easily and as inexpensively...
  • Page 5: Assembly

    ASSEMBLY, PROTECTION and CLEARANCES  APPLICATION:  THIS CAMP STOVE (AKA WALL TENT STOVE) IS A WOOD HEATER AND COOK  STOVE THAT MUST BE USED FOR RECREATIONAL PURPOSES ONLY, SUCH AS ICE FISHING,  CAMPING AND HUNTING. IT WAS NOT DESIGNED FOR RESIDENTIAL HEATING. IT IS IDEAL FOR  COOKING, AS WELL AS HEATING TEMPORARY INSTALLATIONS SUCH AS WALL TENTS.  THE STOVE MUST NOT BE HOOKED UP TO A HOT AIR DISTRIBUTION SYSTEM, AS AN EXCESSIVE  ACCUMULATION OF HEAT MAY OCCUR.   IT IS PROHIBITED TO INSTALL THIS STOVE IN ANY  PERMANENT STRUCTURE, INCLUDING A HOME OR MOBILE HOME.  ASSEMBLY:  Install spring handles    on door and circular  damper (twist them  onto each handle  rod)     Install legs by turning  stove upside down  (or on its back) and  installing two thumb  screws per leg    Page | 5...
  • Page 6: Floor Protection

    TEAR DOWN:  Allow stove to COMPLETELY cool down before removing legs, removing pipe or performing any  tear down or transport.    ACCESSORIES:  *See our website for a full selection of accessories for your camp stove.  Accessories will ship  with instructions included. Please call Technical Support at (800) 245‐6489 with any questions.      FLOOR PROTECTION:  The stove must be placed on a non‐combustible surface.  The following minimum requirements  must apply:  USA  Front  Sides  Rear  Thickness    16”  6”  6”  1/64”  CANADA  18” (460 mm)  8” (200 mm)  8” (200 mm)  Steel Plate 1/64”  (0.38 mm)      CLEARANCES from Combustible Materials:  Back Wall  Side Wall  Corners  Height*  48” (1220 mm)  48” (1220 mm)  48” (1220 mm)  60” (1524 mm)    *Height, from stove’s cooking surface to the ceiling ...
  • Page 7: Installation

    INSTALLATION  Before using your stove in the tent, be sure to cure the paint.  Burn the stove in a safe open  area (such as your driveway or yard) for 2‐3 hours to allow the oils and paint from the  manufacturing process to cure.  Be sure to set up your pipe so that it can cure, also (see pipe  connection ,below).  Begin the fire as a kindling fire and DO NOT achieve high temperatures  quickly, as the paint needs time to cure slowly.  Once the unit is assembled and in place and the minimum clearances are acquired, it must be  coupled to any chimney with a connector (stove pipe).  Verify the clearance between your pipe  and the surrounding combustibles; if the pipe manufacturer’s clearance or local code cannot be  obtained (usually a minimum of 18” or 457 mm), you may use an insulated stove pipe or  thermal shield. READ AND FOLLOW THE PIPE MANUFACTURER’S INSTRUCTIONS.  This stove takes 4” diameter stove pipe.  Pipe Connection: Your pipe system should be assembled so that the male section of each pipe  is oriented down (male end toward the floor). Attach each of the sections together with three  sheet metal screws, placed equidistantly around the pipe. The pipes should be short and  straight. Any sections installed horizontally must slope at least ¼” per foot, with the lower  section toward the stove.  Your stove pipe should extend at least 6” above the ridge of the tent. This reduces the  possibility of spark holes being burnt in the roof.  CAUTION: The use of three sheet metal screws on each section of pipe is particularly important  in windy conditions. Be sure to stake down your tent roof and ridge to prevent movement of  the tent and roof.  Installation of a ‘barometric draft stabilizer’ (fireplace register) on the exhaust system is  prohibited.  However, installation of a draft damper is recommended, in the section of pipe that is closest  to the stove body.    A spark arrestor and rain cap on the top section of pipe is also recommended.    CAUTION: Be sure to check the spark arrestor daily and clean as necessary, as a clogged spark  arrestor can cause smoke to spill out of the stove door or could even cause a fire in the stove  pipe.  Follow the pipe manufacturer’s and the damper manufacturer’s instructions when installing  the damper in the chimney pipe.  Page | 7...
  • Page 8: Operation

    Be sure to have the damper in a fully open position when you start a fire or open the stove’s  door, to reduce smoke billowing (and your tent and clothes from smelling like smoke).  Open  the stove door slowly each time you open it.  CAUTION: The more you use the damper to reduce air flow, use the door draft to reduce air  flow and/or use soft or moist wood, the more creosote buildup you will experience in the stove  pipe and spark arrestor.   Be sure to check your stove pipe and the spark arrestor regularly for  creosote, and clean as necessary.  DRY hardwoods burn the most efficiently and provide the  most heat.    OPERATION  Firebox:  Although your stove does not come with firebrick, it is recommended that you consider  installing and using firebrick to prolong the life of your stove. We offer a firebrick kit as an  accessory, as well as an alternative BottomSaver steel insert that will prolong the life of the  stove’s firebox, as well.  Tip:  DO NOT store the stove with ashes left in the firebox, or premature rust and degradation  of the firebox will occur.  Solid Fuel:  Your stove is designed to burn wood only – no other combustibles (trash or other combustible  materials) should be used.   Different wood types produce different energy yields.  Be sure that your wood is as dry as  possible ‐ many problems related to operating a wood stove are caused by the fact that the  wood is too damp.   Some problems from using damp wood include:  Ignition or Start‐up problems; Creosote  buildup and chimney fires; Low energy (i.e. heat) yield; Incomplete combustion of the wood  Before your first fire:  Be sure to cure your stove and pipe (see INSTALLATION section)  As stated previously, firebrick or the BottomSaver steel firebox insert should be used, to  prolong the life of the firebox.   NEVER use gasoline, gasoline‐type lantern fuel, kerosene, charcoal lighter fluid or similar liquids  to start or ‘freshen up’ a fire in this heater. Keep all such liquids well away from the heater  while in use.  Additionally, never apply fire‐starter to hot embers in the stove. Do not use  Page | 8...
  • Page 9: Starting Your Fire

    chemicals or fluids to start the fire. Do not burn flammable fluids such as gasoline, NAPHTHA or  engine oil.    Be sure the chimney and flue pipe are well installed according the pipe manufacturer’s  directions.  Adhere to all clearances to combustible material, as well as floor protection requirements,  mentioned in this manual.  Do NOT store fuel closer than specified clearances to combustibles or within the space needed  for loading the stove and ash removal.  This unit was designed for operation only with the loading door closed and tightly latched.  Operating this unit with the loading door latched loosely or open will allow excessive  combustion air to reach the fire and will result in dangerously high temperatures. High unit  temperatures can damage the unit, void the warranty or ignite creosote deposited in the flue  system by previous, slow burning fires.  Starting your fire:  Be sure the air intake control on the door is fully open, as well as the damper in the stove pipe.  Place several sheets of rumpled paper in the center of the firebox, then place approximately 8‐ 10 small pieces of dry kindling over the top of the paper, forming a ‘teepee’ shape.  If you place  any heating wood in the firebox at this time, choose very small pieces.   You may also choose solid ‘firestarters’ to help start your fire. (Remember, NO flammable  liquids such as lighter fluid or gas may be used!)  To avoid back draft from cold air outside the structure, you should warm the chimney prior to  igniting the wood in the firebox.  Twist a few sheets of paper into a torch shape, then light it  and hold it as close as possible to the entry of the flue, inside the combustion chamber, to  warm the chimney. USE CAUTION so that you do not burn yourself. Once an updraft into the  flue is initiated, you may light your stove by lighting the paper and kindling teepee that is inside  the firebox.  Leave the stove door slightly opened for 5‐10 minutes, or until good combustion is achieved.  DO NOT leave the fire while the door is opened.  At this time you may close the door and  progressively adjust the air control to achieve the preferred intensity of the fire.    Once you have a bed of embers, reload the unit with larger wood. For safety and best  performance, you should keep your wood load no higher than 6 inches.  Use the circular draft control on the stove door to regulate the intake air for your fire. We  recommend installing a magnetic thermometer on your stove pipe, approximately 18” (46 cm)  above the stove’s surface.  The ideal temperature of the flue pipe is between 250⁰ F and 500⁰ F  Page | 9...
  • Page 10: Cooking

    (121⁰ C ‐ 260⁰ C).  Below this range can encourage creosote buildup, and above this range can  waste heat and potentially lead to over‐firing.  CAUTION: Remember that wood combustion consumes ambient oxygen; as mentioned  previously, be sure to always have some sort of an outside air intake such as a cracked door or  opened window.  England’s Stove Works always recommends the use of a smoke detector and carbon monoxide  detector with any wood stove.  Carbon monoxide is an odorless, colorless gas which can be  deadly. Installing a carbon monoxide detector and being aware of the symptoms of carbon  monoxide poisoning can help reduce the risk of carbon monoxide related issues.  Cooking:  One of the excellent functions of this camp stove is for cooking, and the offset flue enables as  much cooking space as possible.  CAUTION: Remember that the top of the stove will get very HOT.  Use a pan for cooking food on the top of your stove.  Do not cook food directly on the stove  top.  If you find that you must cook directly on the stove top, you should place the food on a  piece of stainless steel (for rust prevention) that can be removed and washed, when finished.  If  rusting does occur over time, you may order a replacement high‐temperature spray paint from  England’s Stove Works to repaint your unit (see Maintenance, below).    MAINTENANCE  Ash Removal: Inspect the firebox daily for ash accumulation, and to insure the firebrick (or the  BottomSaver steel insert) are in place and not damaged.  “Ashes should be placed in a metal container with a tight fitting lid.  The closed container of  ashes should be placed on a noncombustible floor or the ground, well away from all  combustible materials, pending final disposal.  If the ashes are disposed of by burial in soil or  otherwise locally dispersed, they should be retained in the closed container until all cinders  have been thoroughly cooled.”  CAUTION: Keep a fire extinguisher handy at all times, including during ash clean up.  Remember to store the stove with ashes cleaned from the firebox, or premature rust and  degradation of the firebox will occur.    A small open container of a desiccant (i.e. cat litter) in the stove can help prevent corrosion  when the stove is not being used; be certain to remove it before transporting the stove or  building a fire.  Page | 10...
  • Page 11 Pipe: Inspect the flue system to be sure it is properly intact. Inspect the pipe and spark arrestor,  rain cap, etc. for creosote buildup, and clean if necessary.    Door and Gasket: Check the door handle for proper operation and to be certain a tight seal is  being made by the door.    Your stove has a fiberglass gasket installed around the door opening.  Check this to be sure it is  fully intact and is in good condition. If the gasket needs to be replaced, you may purchase  replacement gasket from England’s Stove Works (Part # AC‐DGKCS).  Other: Visually inspect any other parts (including accessories, options, etc.) for proper function.  Finish: This new unit has been painted at the factory with a high‐temperature paint that should  retain its original look for a long time.  If rust spots appear, the spots can be sanded with fine  steel wool and repainted. It is crucial that you use only high‐temperature spray paint (our  proprietary paint is Part # AC‐MBSP), as others may not adhere to the surface or withstand the  high temperatures.        Thanks again for purchasing this stove from England’s Stove Works!     If you should have any questions or need any help with your unit, please contact Technical  Support at (800) 245‐6489.          Page | 11...
  • Page 12 The manufacturer extends the following warranties:  One Year Period:  Carbon steel and welded seams on the product are covered for one (1) year  against splitting.    Conditions and Exclusions  Color and/or integrity of the finish or appearance are not covered.  Damage resulting from over‐firing will void your warranty.  This warranty does not apply if damage occurs because of an accident,  improper handling, improper operation, abuse or unauthorized repair made  or attempted to be made.  The manufacturer is not liable for indirect, incidental, or consequential  damages in connection with the product including any cost or expense,  providing substitute equipment or service during periods of malfunction or  non‐use.*  All liability for any consequential damage for breach of any written or  implied  warranty is disclaimed and excluded.  This warranty does not cover internal wear parts of the combustion system,  including gaskets, firebrick, steel insert, etc.  Warranty is void if product is not used according to the owner’s manual.  The Survivor Camp Stoves are a light weight solution to portable heat and  cooking and not designed for continuous burning.  Extensive burn times  could lead to slight warping which is not covered under warranty.   **Some states do not allow the exclusion of limitations of incidental or consequential damages, so the above  may not apply to you.*  Procedure  Purchaser must give notice of claim of defect within the warranty period  and pay  transportation to and from a service center designated by the manufacturer.  The dealer  from which the unit was purchased or the factory, at our option, will perform the  warranty service.  Other Rights  This warranty gives you specific legal rights; you may also have other rights, which may  vary from state to state.    Page | 12...
  • Page 13: Important Notice

    Important Notice    This registration information MUST be on file for this warranty to be valid.  Please mail this information, along with a copy of the sales receipt, within thirty (30)  days from the original date of purchase.  Use any of these three easy ways to send your warranty information in!  Mailing Address  England’s Stove Works, Inc.   Technical Support Department   P.O. Box 206  Monroe, Virginia 24574  Fax Number  (434) 929‐4810 – Twenty‐four hours a day.  Online Registration  Visit our warranty registration website at:   http://www.heatredefined.com/support/warranty‐registrations/       (WARRANTY REG. CARD LOCATED ON NEXT PAGE)    For more great products, visit our store site:  store.heatredefined.com  Page | 13...
  • Page 14 WARRANTY REGISTRATION for England’s Stove Works®    Purchaser Information      Purchased By (Name)          Address       City   State   Zip Code           Telephone Number       Email Address      Dealer Information       Purchased From        Address        City   State   Zip Code        Unit Information  Model Number   Purchase Date      Serial # __________ ...

This manual is also suitable for:

12-csm12-csl

Table of Contents