Logical systems OKO-2 Operating Manual

Metal and nonmetallic detector

Advertisement

Quick Links

Search kit «ОКО-2»
Operating Manual
OPERATING INSTRUCTION
«Logical systems»
2008г
140104, Russia Ramenskoe city, Moscow region, 100th Svirskoi Divizii st., 11
tel/fax (495) 221-75-58, 221-75-59, 221-75-49
www.logsys.ru
E-mail: info@logsys.ru

Advertisement

Table of Contents
loading

Summary of Contents for Logical systems OKO-2

  • Page 1 Search kit «ОКО-2» Operating Manual OPERATING INSTRUCTION «Logical systems» 2008г 140104, Russia Ramenskoe city, Moscow region, 100th Svirskoi Divizii st., 11 tel/fax (495) 221-75-58, 221-75-59, 221-75-49 www.logsys.ru E-mail: info@logsys.ru...
  • Page 2: Table Of Contents

    1. CONTENTS 1. CONTENTS ........................3 2. DESCRIPTION OF DEVICE OPERATION..............4 2.1 Device designation......................4 2.2 Device structure ......................4 2.3 Arrangements of device operation ................5 2.4 Marking and sealing....................5 2.5 Description and operation of the device component elements ........5 3. WORK WITH THE DEVICE ...................8 3.1 Assembly of the device....................8 3.2 The device in operating position................10 3.3 Preparation for scanning ...................11...
  • Page 3: Description Of Device Operation

    2. DESCRIPTION OF DEVICE OPERATION Device designation Search kit «OKO-2» is automated device and is designed for operative searching and detection dotted and extended metal and nonmetallic objects in various nonmetallic environments (ground, water, building designs and etc.) Device structure The device is the monoblock.
  • Page 4: Arrangements Of Device Operation

    Arrangements of device operation The SK operation is based on well-known radiolocation principals. The SK operation is based on ability of radio waves to be reflected from sections of environment boundaries with a different permittivity. Short signal pulses are applied for subsurface radiolocation. In order to form such pulses the excitation of the wideband transmitting antenna caused by the voltage swing is used.
  • Page 5 2.5.2 Operation device of component parts Receiving and transmitting antenna unit (BAPP) Receiving and transmitting antenna unit functionally consists of receiving, transmitting units and receiving and transmitting antenna unit with volumetric damping resonator. Receiving unit The receiving unit functionally consists of receiving antenna unit, the scan stroboscopic device, selection and storage device (SD) and the control unit.
  • Page 6 The data from BUOI can be copied on a personal computer on interface Ethernet. The transferring order is described in the User’s manual. The further data processing can be made on a personal computer using Geascan32 software (see. The User s guide program Geoscan32). Autonomous power supply unit (BP) The autonomous power supply unit (BP) consists of ten Ni-Mh accumulators and the accumulator indicator of the category, which is control and indicate of the accumulator battery.
  • Page 7: Work With The Device

    3. WORK WITH THE DEVICE Assembly of the device 1. Take from wardrobe trunk SSHP, BP, BUOI, BAPP I/II, cable BP and cable BAPP; 2. Choose the required BAPP according with the depth of search. At depth up to 1 m - BAPP II, from 1 up to 3 m –...
  • Page 8 5. Connect connectors X2 and X3 of folding handle rod with cable of off-line power supply unit (cable marking «Cab. BP»); 6. Connect connectors X1 BAPP and X1 of folding handle rod by antenna cable unit (cable marking «Cab. BAPP»); 7.
  • Page 9: The Device In Operating Position

    The device in operating position. The device is to be in the hand in the position that are shown on the figure 3.2.1 It is necessary to chose the length of the shoulder belt that the major part of weight SK «Оkо-2» will be on the belt and at the same time the freedom of moving SK is provided (figure 3.2.2) BAPP is to be directed at the side of the scanning environment (rejection +_ 20 C from geometrical axis BAPP) and is to be moved in a parallel surface of cargo, close by or with a slight...
  • Page 10: Preparation For Scanning

    Preparation for scanning 1. Press the key on BP case for switching on the power supply of the device. At that time the Led indicator is to flash at the BP case and after several seconds of automatically SK testing and short- time message «Ready», on the BUOI screen is to display operation mode select menu of device (figure 3.3.1) current voltage of power supply unit and time.
  • Page 11: Set Parameters Of Scanning

    The first three half-periods of each line (on the figure 3.3.2 is allocate by a dotted frame in the image of wave form) as so called the signal of direct transmitting. The signal of direct transmitting is not to go to the scanning zone, it is to go directly – from transmitting antenna unit to the receiving and as a rule, it has the biggest amplitude in the current line.
  • Page 12 3. Press the functional key «2» («Epsilon*10», figure 3.4.2) to activate the options of environment dielectric permeability and with the following buttons “↑”and “↓” and to fix the required value of dielectric permeability. The value of dielectric permeability multiplied x10 is displayed on the screen for display convenience of a fractional part of dielectric permeability.
  • Page 13: The Operation Of Scanning

    The operation of scanning 1. Set the antenna power supply unit on the surface which is to scan and press the functional button «2» («Record», figure 3.5.1) for the record of a profile. Figure 3.5.1. Measurements mode menu 2. Smoothly move the antenna power supply unit on the planned trajectory. The search of the deep objects is possible to make at the mode, that is similar to the operation with metal detectors and mine detectors (figure 3.5.2).
  • Page 14 Local objects Figure 3.5.3 The examples of radogramm of detection objects 3. Press button «5» during recording for drawing label. Drawing the label accompany by sound signal. Program assign labels serial number. 4. Press «Esc» for save file and «Enter» for approval of saving (figure 3.5.4). File name Figure 3.5.4.
  • Page 15: Detection Of Movement

    Detection of movement The mode intend for detecting the moving object in real time. Press the functional key «3» in main menu of BUOI («Det. move», figure 3.4.1) to activate the mode. Select item «Param det» (button «5», figure 3.6.1). Figure 3.6.1.
  • Page 16 The main condition for the moving objects detection is to fix the antenna unit on the wall through which the scanning of the adjoining room is made or to fix it on the floor for detection the objects that are below, on the previous floor-level. On the figure 3.6.2 there is a scheme detection of a moving person in the concrete tunnel.
  • Page 17 For detection the moving objects through the wall it is necessary to fix the antenna unit on the wall, do not try to keep the unit by hands, it can make the detection of the moving objects complicated. On the Figure 3.6.4 there is the detection radogramm of the moving animal (dog). The scanning was made through the brick wall of the adjoining room, the thickness is 40 cm.
  • Page 18: General Recommendations

    General recommendations It is necessary to perform the following recommendations during search work: 1. The device should move along the trajectory planned by operator closely or with distance (up to 0,1 m) from the surface of the scanning environment. 2. The speed of the antenna block moving should be no more than 1 km/s while you are scanning the complex surfaces on the relief.
  • Page 19: Viewing Files

    3.10 Viewing files Pressing a“4” functional key in the menu of device operation mode selection («File», figure 3.3.1) select an operation mode “File.” In opening operation mode menu a list of files of profiles with extension *.GPR stored in a hard drive of BUOI is displayed.
  • Page 20 Press the key «Enter» («Open») to open the selected file, the name of the file is displayed at the left corner of the screen. After the file is opened, press the button “Esc” (figure 3.10.3) the menu of the processing file are selected, where become accessible the options of the processing «Processing», «View»...
  • Page 21 «View» button give an access to a menu for handling with a display of radarogramm on a screen of BUOI (figure 3.10.5) Press a “2” functional key («1:1» (figure 3.10.5) and then a Esc key a mode «1:1» is activated. At that if the file size is less than a screen size, then a radarogramm takes only part of a screen ;...
  • Page 22: Settings

    3.11 Settings Press a “4” functional key in a menu of a device operation mode (“Settings”, figure 3.3.1) select an operation mode “Settings“. In an open menu of a Settings mode items of “Palette”, “Time”, and “Test. key” are displayed. 3.11.1 Palette Press a “2”...
  • Page 23 To set up date and time one should set up date and time in corresponding items from which the timer will start counting out. Item selection is made by "←", "→", "↑", "↓"keys. To change the value of a selected item, press an "Enter" key, thereafter you can change the value by "↑"...
  • Page 24: File Transfer From Buoi Into A Computer

    Figure 4.1. Input connector linking up BUOI with PC 2. Switch on PC and Search kit OKO-2 (Settings of network adapter and those of a computer Ethernet port must be the following: IP-Internet protocol address is TCP/IP 10.0.0.100, subnetwork mask is 255.255.255.0, IP-georadar address is 10.0.0.200.).
  • Page 25 After activating a menu item “Processing Unit” in GeoScan32 Program window, a window “Transferring profiles from a Processing Unit” will display. Flash - memory size Copy all the profiles from The election of computer of Processing Unit the Processing Unit to the directory where the files will be copied from the Processing Unit computer...
  • Page 26 Holding a “Ctrl” key, and clicking the left mouse button select files. To select one file it is enough to click the left mouse button on the sign of the required file (figure 4.5). Key for coping the selected files The size and quantity of the selected files Figure 4.5.
  • Page 27: Work With Sk «Око-2» Along With Using A Notebook

    LED indicator will start flashing on a case of PU and in a few seconds after automatic testing SK “Oko-2” and a short time message «ready for work», a device operation mode selection menu will display on a screen of BUOI and a current voltage of BP too;...
  • Page 28: Requirements On Safe Operation And Electromagnetic Compatibility

    LED indicator on the casing of BAPP signals), one may not set the antenna units to the people. Safety of SK «Oko-2» when the standard position of the device is observed (BAPP is set to the investigated cargo and is moved along or under the surface at the distance of up to 0.1 m...
  • Page 29: Routine Servicing

    Battery charging is performed as follows: 1. Connect a power unit (PU)3,8/12 to a charging unit (CU-2); 2. Switch a power unit. 3. Switch on a charging unit to the socket 220 V 50 herz, observing the necessary measures of electrical safety;...
  • Page 30: Transportation

    Device transportation is performed by any transport to any distance in packing of a company manufacturing in observing the following regulations: 1. SK Oko-2 transportation must be performed in a closed transport: railway cars, containers, closed vehicles, holds without any marks of cement or chemicals transportation and so on. When transported by air the apparatus must be placed in a sealed compartment.

Table of Contents