Energy Cube AP4050 Owner's Manual

Energy Cube AP4050 Owner's Manual

Portable generator

Advertisement

3
YEAR
LIMITED WARRANTY
SAVE THIS MANUAL FOR FUTURE REFERENCE
IMPORTANT SAFETY INSTRUC
CUSTOMER SERVICE
SERVICE CLIENTELE
SERVICIO AL CLIENTE
888-980-4936
PORTABLE GENERATOR
Owner's Manual
TIONS ARE INCLUDED IN THIS MANUAL
A-iPOWER Corp.
1477 E. Cedar St. #B,
Ontario, CA 91761
U.S.A.
www.a-ipower.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AP4050 and is the answer not in the manual?

Questions and answers

Peter George
June 6, 2025

Recommended spark plug RN14YC is slightly longer than the original. Is this ok?

Peter George
May 9, 2025

Where can I get parts in ontario canada

Subscribe to Our Youtube Channel

Summary of Contents for Energy Cube AP4050

  • Page 1 YEAR LIMITED WARRANTY PORTABLE GENERATOR Owner’s Manual SAVE THIS MANUAL FOR FUTURE REFERENCE IMPORTANT SAFETY INSTRUC TIONS ARE INCLUDED IN THIS MANUAL A-iPOWER Corp. CUSTOMER SERVICE 1477 E. Cedar St. #B, SERVICE CLIENTELE Ontario, CA 91761 SERVICIO AL CLIENTE U.S.A. 888-980-4936 www.a-ipower.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction..........1 Section 6 — Maintenance....10 Maintenance Schedule........10 Section 1 — Safety Rules.......1 General Recommendations......10 Standards Index...........1 6.2.1 Generator Maintenance......10 6.2.2 To Clean the Generator......10 Section 2 — General Information..4 6.2.3 Engine Maintenance........10 Unpacking...........4 6.2.4 Changing the Oil........11 Assembly.............4 6.2.5 Replacing the Spark Plug......11 6.2.6 Spark Arrester.........11...
  • Page 3: Introduction

    Environmental Protection Agency (EPA). Every effort has been made to ensure that information in this manual is both accurate and current. However Energy Cube. reserves all rights to change, alter, or otherwise to improve the generator and this documentation at any time without prior notice.
  • Page 4 The engine exhaust from this product, certain components in this product and WHEN STARTING EQUIPMENT related accessories contain chemicals known to • Ensure spark plug, muffler, fuel cap, and air cleaner the State of California to cause cancer, birth are in place. defects or other reproductive harm.
  • Page 5 Exhaust heat/gases could ignite Excessively high operating combustibles, structures or speeds could result in minor injury and/or damage fuel tank causing a fire, generator damage. resulting in death, serious injury Excessively low speeds impose a heavy load. • DO NOT tamper with governor spring, links or and/or property damage.
  • Page 6: Section 2 -General Information

    SECTION 2 —GENERAL INFORMATION 2.1 UNPACKING • Set the carton on a rigid, flat surface. • Remove everything from carton except generator. • Open carton completely by cutting each corner from top to bottom. • Leave generator on carton to install wheel kit. 2.1.1 PACKING CONTENTS 1-Owner’s Manual 2-Wheels...
  • Page 7: Section 3 -Features And Controls

    SECTION 3 —FEATURES AND CONTROLS Read this Owner’s Manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. MUFFLER ENGINE SWITCH AC CIRCUIT BREAKER CHOKE LEVER...
  • Page 8: Section 4 - Preparation Before Operation

    SECTION 4 — PREPARATION BEFORE OPERATION 4.1 ADDING ENGINE OIL • Do not mix oil with gasoline. • Install fuel cap and wipe up any spilled gasoline. All oil should meet minimum American Petroleum Institute (API) Service Class SJ, SL or Do not overfill the fuel tank.
  • Page 9: Section 5 - Operation

    SECTION 5 — OPERATION Proper grounding of the generator will help prevent electrical shock in the event of ground fault condition in the generator or in connected 5.1 STARTING THE ENGINE electrical devices. Proper grounding also helps dissipate static electricity, which often builds up Never start or stop engine with in ungrounded devices.
  • Page 10 Move engine choke lever to the CHOKE position. When engine starts, move choke lever to 1/2- CHOKE position until engine runs smoothly and then fully into RUN position. If engine falters, move choke back out to 1/2- CHOKE position until engine runs smoothly and then fully into RUN position.
  • Page 11: Connecting Electrical Loads

    IMPORTANT: Do not overload the generator. Also, do not overload individual panel or decal affixed to be the device. receptacles. These outlets are protected against If the appliance, tool or motor does not give overload with push-to-reset-type circuit breakers. wattage, multiply volts times ampere rating to If amperage rating of any circuit breaker is determine watts (volts×...
  • Page 12: Section 6 - Maintenance

    SECTION 6 — MAINTENANCE 6.1 MAINTENANCE SCHEDULE 6.2.1 GENERATOR MAINTENANCE Generator maintenance consists of keeping the Follow the calendar intervals shown below. unit clean and dry. Operate and store the unit in a More frequent service is required when clean dry environment where it will not be operating in adverse conditions.
  • Page 13: Changing The Oil

    6.2.4 CHANGING THE OIL Change the oil after the first five hours of operation, then every 50 hours thereafter. If running this unit under dirty or dusty conditions, or in extremely hot weather, to change the oil more often. 6.2.6 SPARK ARRESTER Sealing ring •...
  • Page 14: Valve Clearance

    6.4 VALVE CLEARANCE Drain screw After the first 50 hours of operation, check the valve clearance in the engine and adjust if necessary. Inlet valve clearance:0.1-0.15mm; exhaust valve clearance:0.15-0.2mm. Important: If feeling uncomfortable about doing this procedure or the proper tools are not available, please take the generator to the nearest •...
  • Page 15: Section 8 - Troubleshooting

    SECTION 8 — TROUBLESHOOTING Problem Cause Correction 1.One of the circuit breakers is off. 1.Turn circuit breaker to ON. Engine is 2.Fault in generator. 2.contact authorized service facility. running,but no 3.Poor connection or defective cord set. 3.check and repair. AC output is available.
  • Page 16: Section 9 - Parameter

    SECTION 9 — PARAMETER Specification Model AP4050 Engine Kohler 7.0HP Displacement 208cc Rated frequency 60Hz Rated voltage 120 V Running watts 3050W Starting watts 4050W Fuel tank capacity 4 Gallon Full load continuum 8.0H running time 1/2 load continuum 12.0H...
  • Page 17: Section 10 - Diagram

    SECTION 10 — DIAGRAM...
  • Page 18: Section11 - Warranties

    If any emission on the engine purchased. related part on your engine is defective, the part will be repaired or replaced by Energy Cube. The Fuel Metering System warranty period begins on the date the product is Carburetor and/or internal parts delivered to the initial owner.
  • Page 19: Warranty Policy

    Owner’s Manual. terms set forth in this document. COVERAGE TERM ENERGY CUBE GENERATOR Energy Cube warrants to the initial owner and each OWNER LIMITED subsequent purchaser that the spark ignited small WARRANTY POLICY off-road engine is free from defects in materials Do not return to store.
  • Page 20 Energy Cube’s only liability shall be the repair or installation. Similarly, the warranty is void if the replacement of part(s) as stated above in no event...
  • Page 21 ENERGY CUBE WARRANTY CLAIM FORM www.a-ipower.com support@a-ipower.com Primary Information Internal Use Circle one: Serial Number Consumer Dealer Service Did you send in your Warranty Card? If not, proof of purchase is required. Have you ever had a warranty issue with the same unit before?