DXUF 20TN
ATTENTION!
Avoid use of an extension cord because the
extension cord may overheat and cause risk
of fire!
ATTENTION!
In order to avoid a hazard due to inadvertent
resetting of the thermal cutout, this appliance
must not be supplied through an external
switching device, such as a timer or
connected to a circuit that is regularly
switched on and off by the utility!
ATTENTION!
Device not attached near curtains, draperies
and other flammable materials!
2. Technical Device Description
Heat output
Connection voltage
Dimensions in mm (W x H x D)
3. Installation
Fig. 1: Safety distance
4. Electrical Connection
This heater must be used on an A.C.~ supply only and
the voltage marked on the heater must correspond to
the supply voltage.
5. Operation
Main elements - See Fig.2
1- Power Indicator Light
2 - Thermostat control knob
3 - Switch knob
4 - Air outlet
Fig. 1: Main elements
EN-8
Fig.3: Heat control
5.1 Heat Control - see Fig. 3
5.2 Thermostat Control - see Fig.4
The heat output is controlled by the thermostat, accord-
ing to the room temperature. Turn the thermostat knob
fully clockwise to maximum setting initially. When the
2000 W
room is warm enough, reduce the setting slowly until
the heater just clicks off.
230-240 V~, 50 Hz
The heater will now cycle on and off to maintain your
243 x 230 x 163
selected room temperature. An audible click may be
heard when the thermostat operates - this is normal.
If the heater does not come on when the thermostat is
at a low setting, this is normally because the room is
warmer than the thermostat setting and is not a fault.
* When the heat control is set to „
set the thermostat control to maximum.
Position „
a temperature of approximately 5°C.
6. Protection Against Overheating
For your safety, this appliance is fitted with a thermal
cut-out. In the event that the product overheats, the
cut-out switches the heater off automatically. To bring
the heater back into operation, remove the cause of
overheating, then turn off the electrical supply to the
heater for a few minutes. When the heater has cooled
sufficiently reconnect and switch on the heater.
If the cut-out operates repeatedly, contact your sup-
plier.
7. Fuselink
A thermal fuse link is provided as an added safety fea-
ture. If the fuse link operates and opens circuit it is the
result of abnormal overheating within the appliance
and servicing of the appliance by a competent service
engineer will be required in order to ensure the future
safe operation of the heater. Customer services should
be contacted, who will arrange the replacement of any
faulty parts and the fitting of a new fuse link.
DXUF20TN_gb_06_16_B.fm · 08/53116/0 Issue 1
OFF
Cool Blow*
NOTE
NOTE
„ will turn the heater on and off to maintain
Fig.4: Thermostat Control
I
Half Heat
II
Full Heat
„ for cool blow,
www.dimplex.de/en