Summary of Contents for Berker EIB

  • Page 1 EIB Alarm Central Unit Operating Instructions Best. Nr.: 7573 00 10 More Information: Berker GmbH & Co. KG, Klagebach 38 58579 Schalksmühle/Germany Telefon +49 (0) 23 55/905-0 Telefax +49 (0) 23 55/905-112 www.berker.com...
  • Page 2: Table Of Contents

    The system is no substitute for electrician. any mechanical safeguarding devices which prevent intrusion into your property. You can use the EIB alarm central unit as a comfortable extension for any existing EIB This device contains dangerous voltages which can installations.
  • Page 3: Arming Area

    "Armed" The EIB alarm central unit is activated; intruder or sabotage signals within an arming area will set off the alarm. Depending on actual use and distribution of the safeguarding areas, one can distinguish between •...
  • Page 4: Ready For Arming

    EIB Alarm Central Unit Operating Instructions "Alarm" Motor-driven locking element and pulse door opener If a detector responds within an armed safeguarding area, the alarm system will change Entering a safeguarded object should only be possible when the alarm system has to the "alarm"...
  • Page 5: Operation

    – there may be differences. In the all safeguarded doors and windows; motion detectors examples shown here, we use a key-operated switch as arming device and an EIB info must not detect any movements. The display unit will display unit for indication.
  • Page 6: Alarming

    Have your alarm system repaired. As long as the EIB alarm central unit is in the "fault" state, arming of the system is not The flashlight and the alarm transmission device (remote alarm) will continue to be possible.
  • Page 7: Detector Test Mode

    – an alarm detector has been removed If your alarm system includes a corresponding switching option (e. g. a "detector test" or is defective; EIB sensor pushbutton) you can set the system to the "detector test" mode. This • "Sabotage" – a sabotage detector has tripped;...
  • Page 8 EIB Alarm Central Unit Operating Instructions 4. Your EIB alarm central unit - Configuration Locking mechanisms The following brief overview of the essential data of your alarm system (number and, if ____ Blocking element ____ Pulse door opener Other ___________________ necessary, safeguarding areas of the devices) has been composed by your electrician.
  • Page 9 EIB Alarm Central Unit Installation Instructions Best. Nr.: 7573 00 10 More Information: Berker GmbH & Co. KG, Klagebach 38 58579 Schalksmühle/Germany Telefon +49 (0) 23 55/905-0 Telefax +49 (0) 23 55/905-112 www.berker.com...
  • Page 10 EIB Alarm Central Unit Installation Instructions Fig. 1 Dear Electrician and Installer, These Installation Instructions and the Operating Instructions are parts of the EIB alarm central unit and must be handed over to your customer after system start-up. Thank you. Warning Caution: The installation and assembly of electrical equipment may only be performed by a qualified electrician.
  • Page 11: System Information

    2. Function Two-family house, house with granny flat, This EIB alarm central unit is the "intelligence" of an efficient alarm system. Owing to the 2 separate safeguarding areas (workshop with flat). utilization of the instabus EIB installation bus, expensive additional cabling work can be reduced to a minimum.
  • Page 12: Installation

    Refer to Fig. 1 (C). Caution: Disconnect the EIB alarm central unit from the 230 V If wiring to the EIB alarm central unit has to be laid on the surface, it can be led in mains, even when programming the physical address! through the bottom of the device.
  • Page 13 • Supplying external alarm components (e. g. motion detectors or alarm transmission • If alarm indicators are to be triggered through the EIB, the free wires of the EIB cable device) from the alarm central unit will shorten the emergency power supply period.
  • Page 14 The sabotage contacts of the devices in the safeguarded inner area and of the external arming devices should be integrated into the system through the EIB as sabotage The "ÜG-R" terminal will be triggered by the alarm transmission device if there is a fault in detectors.
  • Page 15: Response To Bus Failure

    All other settings must be made with the ETS configuring software. The detector test mode can be activated by an EIB telegram, e. g. from a sensor push- During normal operation, the green "Betrieb" (device ON) LED, Fig. 1 (G) is permanently button installed in a hidden place within the object.
  • Page 16: Multi-Area Configuration Instructions

    The documentation of the entire system is an essential part of any EIB alarm central unit – the switch cabinet door cannot be opened as long as an area is armed (e. g. by a installed.
  • Page 17: Specifications

    EIB Alarm Central Unit Installation Instructions 12. Specifications 13. Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Operating mains voltage: AC 230 VAC, +/- 10 %; 50 / 60 Hz Power consumption: 24 W max.