…………………………………………………………………………………………………………………. Trademarks The Creo wordmark, Creo logo, and the names of the Creo products and services referred to in this document are trademarks of Creo Inc. Adobe, Acrobat, the Acrobat logo and PDF are registered trademarks of Adobe Systems Inc., and are registered in the US Patents and Trademark Office and may be registered in other jurisdictions.
Page 6
The text and drawings herein are for illustration and reference only. The specifications on which they are based are subject to change. Creo Inc. may, at any time and without notice, make changes to this document. Creo Inc., for itself and on behalf of its subsidiaries, assumes no liability for technical or editorial errors or omissions made...
iQsmart Scanners Installation and Maintenance Guide - Macintosh and PC Platforms Table of Contents About This Document Environment Management System (EMS) Chapter 1 Site Preparation General Requirements ............6 Safety Instructions .
Page 8
Table of Contents Chapter 7 Installation Program Stage 1: Launch the Installation & Utilities Application ....... . . 62 Stage 2: Begin the Installation Procedure.
Page 9
iQsmart Scanners Installation and Maintenance Guide - Macintosh and PC Platforms Chapter 10 General Troubleshooting 10.1 Power & Self-Tests ............127 10.2 FireWire Communication Problems .
iQsmart Scanners Installation and Maintenance Guide - Macintosh and PC Platforms About This Document This guide provides detailed instructions about how to install the iQsmart scanner properly, and maintain it in good operational condition. The procedures included in this guide are identical for iQsmart , iQsmart PC, and iQsmart scanners.
Page 12
About This Document Chapter 10, General Suggests ways to solve problems you may come across in your Troubleshooting day-to-day work. Appendix A, Packing the Scanner Instructions on how to pack the scanner for transportation purposes. Appendix B, Technical Technical specifications. Specifications Appendix C, Documentation Folder Instructions on how to use the documentation located on the application CD-ROM.
Page 13
iQsmart Scanners Installation and Maintenance Guide - Macintosh and PC Platforms Document Convention The following conventions are used throughout this document: Item Purpose Example User interface elements, such as menu Select New from the File menu. User interface elements options and icons, are in bold. Click the Expand icon.
Page 14
About This Document Item Purpose Example This icon at the upper right or left corner indicates instructions for MAC users. This icon at the upper right or left corner indicates instructions for PC users. Macintosh/Windows Conventions Macintosh/Windows operating conventions are followed in this guide. We assume that you have a working knowledge of mouse operation, and of standard Macintosh/Windows menus, commands, and dialog boxes.
Page 16
Environment Management System (EMS) Creo is committed to the Environment Management System (EMS) and according to this policy, it updates its customers and the service engineers regarding the principles of handling company products, while placing emphasis on environmental conservation. The three principles (RRR) of the Environment Management System are: •...
Page 17
Cleaning Lenses/Filters Use of environmentally friendly cleaning materials. Packing Materials In principle, packing materials will be kept at the customer's premises, and, if necessary to dispose them, they should be sent to a plant for recycling paper, cartons and wood. End of Product Lifespan The product should be sent for recycling to a recognized company in each country.
Chapter 1 Site Preparation General Requirements This chapter describes the conditions that are necessary for proper iQsmart site preparation. Site Place the shipping package as close as possible to its final location. Before unpacking and installing the scanner, make sure the unpacking site is large enough to allow easy maneuvering.
Page 21
General Requirements Important: • Make sure the table is stable. • Do not mount the table on a floating floor. • The table should be dedicated for the scanner only. Do not place the monitor, keyboard, computer, or other peripheral devices on the table.
Page 22
Chapter 1 Site Preparation Minimum Requirements for iQsmart Scanners • Apple Power Macintosh G4 • Apple Macintosh system software version 9.1 or higher • CD drive (required for software installation) • 200 MB of available memory (RAM) for the oXYgen scanning application, in addition to memory needed for the system software •...
General Requirements Minimum PC System Requirements • Intel® Pentium® III or IV processor with minimum speed of 866 MHz • Microsoft® Windows 2000 with Service Pack 2, or Microsoft® Windows XP • CD drive (required for software installation) • 256 MB of RAM available for scanning application •...
This warning icon, which appears in this manual, appears also inside the scanner in the Electronic box. It indicates that, in order to reduce the risk of electric shock, the cover must not be removed. Refer servicing to qualified Creo service personnel.
Chapter 2 Unpacking Unpacking the Scanner The first stage in the installation procedure is to unpack your iQsmart scanner, and place it on the table. This chapter describes how the scanner package is opened and unpacked. Unpacking the scanner involves the following steps: •...
Page 27
Unpacking the Scanner Remove first the Installation (‘Open Me First’) kit and use the Installation Guide for further instructions during the installation. [1] Installation (Open Me First) kit [2] iQsmart Installation Guide (inside the Installation kit) [3] oXYgen Training package [4] Mask kit (at the bottom of the carton;...
Page 28
Chapter 2 Unpacking Remove the top foam corners.
Page 29
Unpacking the Scanner Open the transparent plastic wrapping of the scanner. Find the holding niche beneath the frame of the scanner (length-wise), carefully lift the scanner, and place it on the table. Remember, the scanner weighs approximately 35 kg (77 lb), and two people are required to lift it.
Chapter 2 Unpacking 2.1.1 Installation Kit (required for installation on Macintosh) • iQsmart Scanners Installation & Maintenance Guide - Mac and PC Platforms • Scanner software CD, including User Guide PDF files (in English, French and German). • Power cable, 3 m (American type) •...
Unpacking the Scanner 2.1.3 Included Packages and Kits (not required for installation) • oXYgen Training package Scanning Solutions User Guide • Tutorial (CD) • WBT (CD) • Pack Mask kit User defined masks (6 pieces) • 6x7 cm mask (1 piece) •...
Chapter 2 Unpacking Unlocking Screws and Removing Packing For the procedures in this section, a flat screwdriver is required. It is supplied in the installation kit. Open the top cover. You will find a foam and a cardboard with unlocking instructions. Save the cardboard and the foam (inside the Installation kit) for...
Page 33
Unlocking Screws and Removing Packing Insert the flat screwdriver in the screw located on the top right UNLOCK corner of the scanner bed, and turn the screw 180° clockwise to open it. The red spot on the screw is up when the screw is unlocked.
Chapter 3 FireWire Installation for PC Platform FireWire Adaptor Installation..... 23...
Page 36
Chapter 3 FireWire Installation for PC Platform The next stage in the installation procedure is installing the FireWire adaptor for PC users. The 1394 IEEE (FireWire) adaptor is located in the PC Add-on Installation kit. Important: Before starting the installation, make sure that the computer, the scanner, and all other devices are switched off.
FireWire Adaptor Installation FireWire Adaptor Installation The next stage in the installation procedure is to connect the PCI FireWire adaptor to your computer. Please consult your System Administrator before starting the FireWire adaptor installation process. FireWire adaptor installation involves the following steps: Before starting, turn power OFF to the computer, and disconnect the power cord.
Page 38
Chapter 3 FireWire Installation for PC Platform Locate an unused PCI extension slot (typically white or ivory) and remove the extension slot cover screw, then remove the extension slot cover. Save the slot cover screw for use in Step 4. Extension slot cover PCI Extension...
Page 39
FireWire Adaptor Installation Remove the FireWire adaptor from its anti-static packaging. Always handle the adaptor by its edges. Discharge any static electricity built-up before handling the FireWire adaptor by touching a grounded metal object (such as the exposed metal parts on the back of your computer). Goldfingers (do not touch these)
Page 40
Chapter 3 FireWire Installation for PC Platform Carefully insert the FireWire adaptor into the PCI extension slot, pressing it down firmly so the gold fingers are seated in the slot (see the figure in Step 3). Secure the FireWire adaptor with the slot cover screw you removed in Step 2.
Page 41
FireWire Adaptor Installation In the Control Panel window, click the System icon; the System Properties window is displayed.
Page 42
Chapter 3 FireWire Installation for PC Platform In the System Properties window, click the Hardware tab. Save the cardboard and the foam (inside the Installation kit) for future use in lamp replacement.
Page 43
FireWire Adaptor Installation In the Hardware tab screen, click Device Manager; the Device Manager window is displayed. Click the Plus sign next to the IEEE 1394 Bus Host Controllers to see the IEEE 1394 host controller. In the example above, the host controller is Texas Instruments. It can, of course, be a host controller of any other brand name.
Chapter 4 Powering On Powering on the Scanner This chapter explains how to power on your iQsmart scanner. To connect your scanner and power it ON: Locate the power cable in the installation kit. The power cable is a North American type that complies with US and Canadian requirements.
Page 47
Powering on the Scanner Make sure that the scanner is powered OFF (the main power switch is on the back of the scanner).
Page 48
Chapter 4 Powering On Connect the power cable to the power supply inlet located on the back panel of the scanner. Connect the other end of the cable to a grounded electrical power outlet.
Page 49
Powering on the Scanner Power the scanner ON. The scanner enters Standby mode.
Page 50
Chapter 4 Powering On Press the Power pushbutton on the Operating panel to switch the scanner ON.
Startup Sequence Startup Sequence Power ON the scanner (the main power switch on the back of the scanner), then press the Power button on the Operating panel to switch the scanner ON. When you switch ON the scanner, the Power LED on the operating panel is green.
Chapter 5 Software Installation Installation Procedure - Macintosh Computers The iQsmart software is provided on a CD located in the Installation kit package. Insert the CD into the CD-ROM drive, and double-click the oXYgen Software icon. The following window is displayed. See Appendix C, Documentation Folder for instructions on how to install and use the documentation located in the Documents folder.
Page 55
Installation Procedure - Macintosh Computers Click Continue. The following message is displayed. Click Continue. The oXYgen Installer window opens.
Page 56
Chapter 5 Software Installation In the scanner list, select your scanner. Click Install. The following dialog box is displayed. The dialog box shows where, by default, the software will be installed. If you want to install the software in another location, select the folder into which you want to install the software.
Page 57
Installation Procedure - Macintosh Computers The installation program continues automatically from this stage on. The counter shows the number of items that have been installed. When installation is complete, the following window is displayed. Click Restart. The system restarts. The scanner software is now installed, and the oXYgen Software folder is automatically displayed.
Page 58
Shows which type of iQsmart scanner is connected to the FireWire bus. Folders iQsmart Tables Creo-supplied tables. MatchBuilder v.1.0.0f Creates transformation tables which simulate proof or final print colors on your monitor. Every time you enter the Scanning or Installation...
Installation Procedure - Windows Operating System Installation Procedure - Windows Operating System The iQsmart software is provided on a CD located in the PC Add-on Installation kit. Insert the CD-ROM into the CD-ROM. After few seconds, the oXYgen Scan screen window appears. See Appendix C, Documentation Folder for instructions on how to install and use the documentation located in the Documents folder.
Page 60
Chapter 5 Software Installation After a few seconds, the Setup prepares the Installation Wizard. The Welcome window opens. Click Next to continue with the Setup program; the Choose Destination Location window opens. It shows where, by default, the Scanner folder will be placed.
Page 61
Installation Procedure - Windows Operating System Click Next to install the oXYgen Scan application to the default folder. To place the folder in another location, click Browse. The Choose Folder window appears. Select the storage location, and click OK to return to the Choose Destination Location window.
Page 62
Chapter 5 Software Installation Click Yes to continue with the installation. During installation, a progress bar shows what percentage of time has elapsed. Setup starts copying files to your computer.
Page 63
Installation Procedure - Windows Operating System When Setup has finished copying files, the Installation Complete window opens. Click Finish. The oXYgen Scan screen window appears. Click Exit and remove the CD from the CD-ROM drive.
Page 64
Device color tables User Application Install&Utils For scanner installation and automatic creation of tables iQsmart Tables Creo-supplied tables Log folder Every time you enter the Scanning or Installation and Utility application, existing application log files are erased and new application log files...
Chapter 6 Scanner Configuration Configuring the Scanner ......53 Connecting the Scanner ......56 Checking FireWire Communication (Macintosh).
Page 66
Chapter 6 Scanner Configuration The next stage in the installation procedure is to connect your scanner to the computer. Important: Before connecting the scanner, make sure that the computer, the scanner, and all other devices are switched OFF. FireWire configuration involves the following steps: •...
Configuring the Scanner Configuring the Scanner Set up your scanner less than 4.5 meters from the computer. From the installation kit, remove the FireWire cable.
Chapter 6 Scanner Configuration 6.1.1 Connector Socket Location There are two connector sockets, identified by the FireWire label (IEEE1394). The sockets are located on the back of the scanner. The connectors are connected in parallel, to enable a "daisy-chain" FireWire configuration. Connector sockets...
Configuring the Scanner 6.1.2 Connecting FireWire Cable When connecting the FireWire cable into the connector socket, pay attention to the shape of the connector socket. Connect the cable to the connector socket carefully, without applying too much pressure. There is a connector socket both on the back panel of the scanner and at the back of the computer.
Chapter 6 Scanner Configuration Connecting the Scanner Scanner connected directly to the computer - RECOMMENDED The above figure shows an example of the scanner Macintosh configuration. The scanner configuration for PC is the same. • Connect the FireWire cable (1) from one of the scanner connector sockets to the FireWire board connector on the back panel of the computer.
Double-click the FireWire Probe icon located in the iQsmart folder. The FireWire chain is scanned, and the connected scanner is displayed, as shown in the following figure. Click Quit to close the window. The FW Scanner Probe application recognizes only Creo scanners, and no other FireWire devices.
Chapter 6 Scanner Configuration Checking FireWire Communication (PC) Execute the following sequence to display the Control Panel window: Start→Settings→Control Panel. In the Control Panel window, click the System icon. The System Properties window is displayed. In the System Properties window, click the Hardware tab.
Page 73
Checking FireWire Communication (PC) In the Hardware tab screen, click Device Manager. The Device Manager window is displayed.
Page 74
Click the Plus-signs next to IEEE 1394 Bus Host Controllers to expand it and verify the system recognizes the host controller. • Click the Plus-signs next to Imaging Devices to expand it and verify the system recognizes the Creo iQsmart scanner.
Chapter 7 Installation Program Stage 1: Launch the Installation & Utilities Application . 62 Stage 2: Begin the Installation Procedure... 63 Stage 3: Enter the Serial Number ....64 Stage 4: Prepare the Scanner.
Chapter 7 Installation Program At this stage of the installation procedure for PC and Macintosh, your scanner is switched ON, is connected to the system, and the scanning software is loaded in the computer. This chapter explains the Full Install procedure, which takes approximately 1.25 hours.
Stage 2: Begin the Installation Procedure After a few seconds, the Installation & Utilities screen appears, as follows. Click Continue. The Scanner Installation screen is displayed: Stage 2: Begin the Installation Procedure In this screen, all the Installation Stage options are selected and unavailable.
Chapter 7 Installation Program Stage 3: Enter the Serial Number After a few seconds, the Scanner Serial Number screen is displayed: To enter the scanner serial number: Enter the scanner serial number. The number is displayed in one of the following locations: •...
Page 79
Stage 3: Enter the Serial Number Scanner serial number...
Page 80
Chapter 7 Installation Program The scanner serial number appears on the calibration slide, as shown in the following illustration:...
Stage 4: Prepare the Scanner Stage 4: Prepare the Scanner A message is displayed instructing you to clean the glass and place the calibration slide on the scanner. To prepare the scanner: Prepare the cleaning cloth and the calibration slide (in the Installation kit).
Page 82
Chapter 7 Installation Program Clean the base glass and upper glass plates. We recommend using clear domestic glass cleaning solution to clean all flat glass surfaces, as it leaves no trace after drying. The cleaning solution should not contain wax or ammonia. Be sure not to pour cleaning solution directly on the glass, as it might leak inside.
Page 83
Stage 4: Prepare the Scanner Place the calibration slide on the base glass: the pin holes in the slide should fit over the two right-hand pins at the top side of the base glass. The sticker on the calibration slide should be as shown in the figure below.
Chapter 7 Installation Program Stage 5: Automatic Diagnostics Check (Macintosh) An automatic diagnostics check is performed, and the following window appears showing the results: The results can be either Passed or Fail. If all tests pass, the application automatically moves on to the next stage.
Stage 5: Automatic Diagnostics Check (PC) Stage 5: Automatic Diagnostics Check (PC) An automatic diagnostics check is performed, and the following window appears showing the results: The results can be either Passed or Fail. If all tests pass, the application automatically moves on to the next stage. If any test fails, the following message is displayed.
Chapter 7 Installation Program Stage 6: Automatic Optics Check An automatic Optics check is now performed. The results can be either Passed or Out of Tolerance. If the test passes, the application automatically moves on to the next stage. If the test result is Out of Tolerance, see Section 7.12.7 on page 82.
Stage 8: Backup Generated Tables (Macintosh) Stage 8: Backup Generated Tables (Macintosh) To back up generated tables: At this point, a message is displayed prompting you to back up the generated table results to a media or to another location. Click Yes.
Chapter 7 Installation Program 7.10 Stage 8: Backup Generated Tables (PC) To back up generated tables: At this point, a message is displayed prompting you to back up the generated table results to an external media (recommended). Click Yes. As a precaution, we recommend that you back up the newly created tables.
Stage 9: Quit Installation 7.11 Stage 9: Quit Installation After the tables are copied, a message window is displayed confirming the installation has been successfully completed. Click Done to return to the main menu. You may now remove the calibration slide. Important: After you finish the installation procedure, keep the calibration slide in a place that is dark, cool, and safe.
Chapter 7 Installation Program 7.12 Troubleshooting for the Installation & Utilities Program Description and Solution Problem on page... Serial Number Mismatch Serial Number Mismatch (second time) Wrong Media Inserted Diagnostics Check Failure (Macintosh) Diagnostics Check Failure (PC) Calibration Slide Incorrectly Placed Optics Check: Out of Tolerance 7.12.1 Serial Number Mismatch Problem...
Troubleshooting for the Installation & Utilities Program 7.12.2 Serial Number Mismatch (second time) Problem If the number entered still does not match, a message window appears on the screen requesting insertion of the scanner parameters backup CD. If the backup file was saved to another location, click Browse to find it.
Chapter 7 Installation Program 7.12.3 Wrong Media Inserted Problem If the backup media also has a serial number mismatch, or a wrong media has been inserted, or a wrong file was selected, a message window is displayed requesting you to insert the correct media. Solution If there is no other parameter media (CD), click No Backup.
Troubleshooting for the Installation & Utilities Program 7.12.4 Diagnostics Check Failure (Macintosh) Problem If any of the scanner hardware does not pass the diagnostics check, a fail message appears in the Diagnostics Checks window. Solution Click Continue to continue with the installation program. If the Continue button is disabled, click Quit to exit to the main screen, and contact your service center.
Chapter 7 Installation Program 7.12.5 Diagnostics Check Failure (PC) Problem If any of the scanner hardware fails the diagnostics check, the following window and message appear: Solution Click Continue to continue with the installation program. Click Quit to exit to the Main Installation menu, and contact your service center.
Troubleshooting for the Installation & Utilities Program 7.12.6 Calibration Slide Incorrectly Placed Problem The scanner verifies that the calibration slide has been placed on the scan carriage, and is inserted correctly. If this test fails, a message repeats the request to place the calibration slide correctly. Solution Follow the instructions in the screen, and click Proceed.
Chapter 7 Installation Program 7.12.7 Optics Check: Out of Tolerance Problem During the Optics check, an Out of Tolerance message is displayed. Solution In this case, the previously generated tables remain intact. New tables will not be generated. Click Quit to return to the main window. Repeat your scan using the previously generated parameters.
Chapter 8 Utilities Status Screen ....... . 85 Fast Install........86 Scanner Checks .
Page 98
Chapter 8 Utilities This chapter describes the installation program utilities and the log folder. The Installation & Utilities program is used to install the scanner. The program contains the following utility options: • Fast Install page 86 • Scanner checks page 89 •...
Status Screen Status Screen While a utility program is running, you can view the progress of the process, by selecting the Show Status option from the Windows menu, on the Menu bar. After you select the Show Status option, the following window is displayed.
Chapter 8 Utilities Fast Install (accessed via the Installation Program item) The Fast Install utility is used to copy the parameters from the scanner instead of creating them. To perform a Fast installation, do the following: Double-click Install&Utils. The Installation &Utilities screen is displayed.
Page 101
Fast Install a few seconds, the Installation & Utilities window is After displayed. Select Installation Program, and click Continue. In the Installation window that is displayed, from the drop-down menu, select Fast Install. When you select the Fast Install option, only Load Parameters is enabled.
Page 102
Chapter 8 Utilities Select the Load Parameters option, and click Install. The following window is displayed. Enter the scanner serial number and click Confirm. The parameter loading process starts. When the process is completed, a message appears confirming the parameter loading was successfully completed.
Scanner Checks Scanner Checks The Scanner Checks utility checks the scanner modules and optics. You are required to activate this utility only when a scanner operational problem arises. To activate this utility: Double-click Install&Utils. The Install&Utils window is displayed. Select Scanner Checks, and click Continue. The following window is displayed.
Page 104
Chapter 8 Utilities See the cleaning instructions in Section 7.4 on page 67. Follow the instructions, and click Proceed. The Scanner Checks procedure continues automatically, with the Diagnostics and Optics checks. If the Diagnostics check and the Optics check pass successfully, the following message window is displayed: If an error occurs during the Diagnostics check or the Optics check, in the error message window that appears, click Continue.
Create Tables Create Tables This option is used when tables need to be created. Double-click Install&Utils. The Install&Utils window is displayed. Select Create Tables, and click Continue. The following window is displayed. Enter the scanner serial number and click Confirm. A message is displayed instructing you to clean the glass and place the calibration slide on the scanner.
Page 106
Chapter 8 Utilities You have three options in the Create Tables Options list: • Create All (the default option) • Enlargement < 700% • Enlargement > 700% Select the required option, and click Activate. A message is displayed instructing you to clean the glass and place the calibration slide on the scanner.
Page 107
Create Tables Follow the instructions, and click Proceed. The Create Tables window is displayed, and a fully automatic procedure begins. See Section 7.9 Stage 8: Backup Generated Tables (Macintosh) on page 73,or Section 7.10 Stage 8: Backup Generated Tables (PC) on page 74.
Chapter 8 Utilities Backup Parameters Choose this option when parameters have to be: • Loaded from the backup media to the computer and to the scanner memory. Backing up the parameters is performed without any optics check or creation of tables. You may need to use this option, for example, if your EverSmartDb.iQsmart3 file is erased or becomes corrupted.
Page 109
Backup Parameters Select one of the following options: • Load from Backup Media to overwrite the parameters on the computer. This option enables faster installation (when previous parameters are to be used). • Save to Backup Media to save the parameters on the computer to a backup media or to another location.
Chapter 8 Utilities CreoScan_Log Folder iQsmart activity is automatically recorded in the following files located in the CreoScan_Log folder: • AssemblyResults.txt • Install&UtilResultFile.txt • DiagnosticsResultFile.txt • LogFileInstall&Utils • EverSmartDb.iQsmart These files are located in the CreoScan_Log Folder, and contain text information concerning the test results and descriptions of the test processes.
Chapter 9 Maintenance This chapter explains how you maintain the following scanner components. Replacing: Lamps • Transparency lamp unit • Reflective lamp unit • Electronic box (See Appendix Electronic Box E Scanner Electronic Box on page 161) Cleaning the upper and base glass Glass plates Lamp Unit Replacement The scanner operates with the following lamp units:...
Lamp Unit Replacement 9.1.1 Replacing the Transparency Lamp Unit The transparency lamp unit is located inside the scanner top cover. Light level is too low The following message window is displayed on the screen. To exit from the message window, perform one of the following: Click Abort.
Page 114
Chapter 9 Maintenance Replacement Procedure To replace the transparency lamp unit, perform the following: To avoid bodily injury, prior to the lamp replacement, power the scanner OFF (the main power switch is on the back of the scanner). The transparency lamp unit is hot. Wait a few minutes for it to cool off before replacing it.
Page 115
Lamp Unit Replacement Holding the plastic frame with the transparent lamp unit, unlock Open the five screws on the top cover. To open the screws, rotate them 90° counterclockwise. There is no need to remove the screws. Close...
Page 116
Chapter 9 Maintenance After opening the five screws, the plastic frame with the transparency lamp unit is released from the top cover. Place it down on the scanner bed to expose the transparency lamp unit. Important: Place the foam between the base glass and the unit before removing the lamp unit to prevent damage to the scanner base glass.
Page 117
Lamp Unit Replacement Important: Place the foam between the transparent lamp unit and the upper glass in order to avoid damage to the upper glass. Disconnect the lamp unit connector.
Page 118
Chapter 9 Maintenance Release the lock screw on the side of the transparency lamp unit.
Page 119
Lamp Unit Replacement Carefully remove the unit by pulling it to the left. Carefully insert a new transparency lamp unit. Insert the two holes on the sides of the lamp unit into the two guide pins in the lamp unit holder. Make sure not to touch the lamp unit window that faces down.
Chapter 9 Maintenance 9.1.2 Replacing the Reflective Lamp Unit The reflective lamp unit is located beneath the base glass. Light level is too low The following message window is displayed on the screen. To exit from the message window, perform one of the following: •...
Page 121
Lamp Unit Replacement Press the Status pushbutton on the Operating panel for approximately 10 seconds. The Reflective lamp unit assembly moves to the center of the glass plate. Switch the scanner OFF, then power it OFF (the main power switch is on the back of the scanner). The reflective lamp unit is hot.
Page 122
Chapter 9 Maintenance Unscrew the four screws that fasten the base glass to the scanner. The screws should be rotated 90° counterclockwise. Closed Open...
Page 123
Lamp Unit Replacement Lift the two handles of the base glass. Pull out the base glass.
Page 124
Chapter 9 Maintenance Place the base glass on a soft surface.
Page 125
Lamp Unit Replacement Remove the reflective lamp unit in two steps. First, disconnect the lamp unit connector.
Page 126
Chapter 9 Maintenance Then, press the plastic notch at the top end of the unit. You may have to move the reflective lamp assembly (part of the whole lamp assembly) down toward you to reach the plastic notch.
Page 127
Lamp Unit Replacement Slide the lamp unit out.
Page 128
Chapter 9 Maintenance Carefully insert a new reflective lamp unit by sliding it in until it snaps into place, and connect the lamp unit connector. Lift the base glass up (using the handles) and place it back in its original position (on the scanner frame). When you place the glass back, make sure the “Keep Clean”...
Cleaning the Glass Cleaning the Glass The upper and base glass plates require periodic cleaning. We recommend using clear domestic glass cleaning solution to clean all flat glass surfaces, as it leaves no trace after drying. The cleaning solution should not contain wax or ammonia. Do not pour cleaning solution directly on the glass, as it may leak under the glass surfaces.
Chapter 9 Maintenance 9.2.1 Upper Glass Cleaning First switch OFF the scanner, and then power it off (the main power switch is on the back of the scanner). The transparency lamp unit is hot. Wait a few minutes for it to cool off before starting to clean the upper glass.
Page 131
Cleaning the Glass Holding the plastic frame with the transparent lamp unit, unlock Open the five screws on the top cover. To open the screws, rotate them 90° counterclockwise. There is no need to remove the screws. Close Place the plastic frame on the scanner bed with the glass down to expose the upper glass.
Page 132
Chapter 9 Maintenance Clean the glass plate surface (the inner side). Lift the plastic frame up and tighten the five screws by pressing Open and rotating them 90° clockwise. Make sure to tighten the screws properly. Close Clean the upper glass surface (from the outside).
Cleaning the Glass 9.2.2 Base Glass Cleaning First switch OFF the scanner, and then switch off the main power (the main power switch is on the back of the scanner). The lamps in the lamp tray are hot. Wait a few minutes for the lamps to cool off.
Page 134
Chapter 9 Maintenance Lift the two handles of the base glass. Pull out the base glass.
Page 135
Cleaning the Glass Turn the base glass upside down and place it on a soft surface.
Page 136
Chapter 9 Maintenance Clean the base glass surface, making sure you do not touch the white sticker running along the side of the glass. After you clean the glass, grip the handles firmly, turn it around, and place the glass back in its original position. Tighten the four screws that secure the glass plate to the scanner.
Covering the Scanner Covering the Scanner When the scanner is not in use for five or more hours, we recommend covering the scanner with the plastic cover to avoid the penetration of dust and dirt into the scanner internal optic components. The plastic cover is located in the Scanner Installation kit.
Chapter 10 General Troubleshooting Power & Self-Tests ......127 FireWire Communication Problems ....128 Scanning Quality.
Page 140
Chapter 10 General Troubleshooting This chapter describes some problems that may arise during scanning, and their solutions. • If the problem was solved, you can continue scanning. • If the problem remains, try the next suggestion. • If you have tried all the suggestions, and the problem persists, contact your service center.
Power & Self-Tests 10.1 Power & Self-Tests Symptom • The Power and Status LEDs do not light up. Suggestions • Check that the power cable is connected correctly. • Check the power outlet in the room. See Electrical on page 6. •...
Chapter 10 General Troubleshooting 10.2 FireWire Communication Problems Symptom • The “No communication with scanner. Turn scanner ON and check FireWire connections” message is displayed prompting there is a communication problem. Suggestion 1 • Switch the scanner OFF, then ON. After a few seconds, verify that the Status LED is a constant green.
Page 143
• Open the Extension folder and make sure the FireWire Enabler, FireWire Support (Apple extensions) and the Scanner FireWire Driver extensions (Creo extension) exist. • If the FireWire Enabler and FireWire Support extensions are missing, load the Apple System software (Mac OS).
Page 144
Chapter 10 General Troubleshooting Suggestion 2 (PC) • Make sure the scanner is switched and the FireWire cable is connected to the scanner and to PC FireWire port. • Verify that the scanner driver is properly installed by checking that it appears in the Device Manager window.
Page 145
FireWire Communication Problems • If the scanner driver does not appear in the Device Manager window under Imaging Devices, do the following: • Check for Unknown Device (under Other Devices) or for Generic Printer (under 1394 SCSI Scanner). • If Unknown Device (under Other Devices) or Generic Printer (under 1394 SCSI Scanner) appears, do the following: •...
Page 146
Chapter 10 General Troubleshooting • In the Generic Printer window, click the Driver tab, and then click the Update Driver button to launch the Upgrade Device Driver wizard. • In the Welcome window, click Next to open the Install Hardware Device Drivers window.
Page 147
FireWire Communication Problems • Make sure the Search for a suitable driver for my device option is selected, and click Next. The Locate Driver Files window is displayed.
Page 148
Chapter 10 General Troubleshooting • Select the Specify a location option, and click Next. The following window is displayed: • Insert the oXYgen LE-Windows scanner software CD into the CD-ROM drive, and click Browse.
Page 149
FireWire Communication Problems • In the Insert File window, locate the iQsmart.inf file (under CD drive\Drivers\iQSmart driver). • Click Open. The Driver Files Search Results window is displayed. • Select the Install one of the other drivers option, and click Next. The Driver Files Found window is displayed.
Page 150
Chapter 10 General Troubleshooting • Select the Creo iQsmart driver, and click Next. The Digital Signature Not Found window is displayed. • Click Yes. The Completing the Upgrade Device Driver Wizard window is displayed.
Page 151
FireWire Communication Problems • Click Finish to complete the device driver upgrade process. The Device Manager window is displayed. • Click the Plus-sign on the line of the Imaging Devices to expand it, and check that Creo iQsmart appears on the list.
Chapter 10 General Troubleshooting 10.3 Scanning Quality Symptoms • Vertical lines in the picture. • Unsharp picture. • Unfocused picture. • Shift in the crop. • Misregistration between color channels. Suggestions • Run the Scanner Check procedure from the Installation & Utilities application.
Scanner/Application Hangs • Make sure that the original is placed on the base glass according to one of the following: • The original is taped directly onto the base glass. • The original is taped onto a mask that is placed on the registration pins.
Appendix A Packing the Scanner Locking the Scanner This appendix provides instructions on how to pack the scanner when it is necessary to transport it from one location to another. Power ON the scanner (the main power switch is on the back of the scanner), and then switch it ON.
Packing the Scanner Packing the Scanner Make sure the bottom foam corners are in the carton. Find the holding niche beneath the frame of the scanner (length- wise), carefully lift the scanner, and place it in the carton. Remember, the scanner weighs approximately 35 kg/77 lb, and two people are required to lift it up.
Page 158
Appendix A Packing the Scanner Wrap the plastic on top of the scanner. Insert the top foam corners in the space between the scanner corners and the outer carton (these are required to prevent movement of the scanner).
Page 159
Packing the Scanner Insert the kits inside the carton. [1-2] [1] Installation (Open Me First) kit [2] iQsmart Installation Guide (inside the Installation kit) [3] oXYgen Training package [4] Mask kit (at the bottom of the carton; not visible in the picture) Close the top cover and tape the carton.
Page 160
Appendix A Packing the Scanner Use straps to attach the wooden palette to the carton.
Appendix C Documentation Folder Documentation Folder (Macintosh) The Macintosh Documentation folder is located on the oXYgen scanning software CD. The documents are in Adobe Acrobat PDF file format, so you need to install Adobe Acrobat Reader or higher. Installation instructions are included in this appendix. The contents of this appendix appear in the Readme file located in the above Documentation folder.
Documentation Folder (Macintosh) • The Documentation folder contains the following files and folders: • oXYgen User Guide folder • DOT Solution folder • iQsmart Installation Guide folder • iQsmart Feedback Form.pdf • EverSmart Feedback Form.pdf The manuals are in Adobe Acrobat PDF file format. In order to view or print these files you must have the Adobe Acrobat Reader installed.
Appendix C Documentation Folder Documentation Folder (PC) The PC Documentation folder is located on the oXYgen LE-Windows scanning software CD. The documents are in Adobe Acrobat PDF file format, so you need to install Adobe Acrobat Reader version. Installation instructions are included in this appendix. When you insert the oXYgen LE-Windows scanning software CD, the following window is displayed.
Make sure you have at least 10 MB of available disk space for an installation of Acrobat Reader. Insert the oXYgen LE-Windows scanning software CD into the CD-ROM drive. In the Creo iQsmart Install window that is displayed, click Install Acrobat Reader. Follow the Adobe Acrobat Reader instructions on the screen.
Appendix D Log File Application Log File Application (Macintosh) After launching any scanner application, the Creo Scan_Log folder that contains all the application log information is created. The folder is located in the oXYgen Scan folder. If you encounter any problems in imaging quality, you might be requested by your service center to send them the CreoScan_Log folder located in the oXygen Software Application folder.
Log File Application (PC) Log File Application (PC) After launching any scanner application, the Creo Scan_Log folder that contains all the application log information is created. The folder can be accessed by executing the following sequence: →Log Folder. Start→Programs→iQsmart If you encounter any problems in imaging quality, you might be requested by your service center to send them the CreoScan_Log folder.
Appendix E Scanner Electronic Box Removing Scanner Electronic Box Scanner electronic box can be removed only with the approval of the Service center. To remove the Electronic box, perform the following: Switch OFF the scanner, and then power it OFF (the main power switch is on the back of the scanner) Disconnect the power cable from the scanner back panel.
Page 177
Removing Scanner Electronic Box Pull the two small handles toward you to remove the electronic box.
Appendix E Scanner Electronic Box Installing Scanner Electronic Box To install the scanner electronic box, perform the following: Gently slide the electronic box into place at the back of the scanner. Tighten the two thumb screws. Connect the FireWire cable to the back panel of the scanner. Connect the power cable to the power supply inlet located on the back panel of the scanner.
Page 179
Installing Scanner Electronic Box Startup Troubleshooting If the startup sequence is not completed successfully, one of the following events will occur: • The Status LED remains red (possible hardware fault). • The Status LED remains blinking red and the Power LED is red because one of the safety switches was activated.
Page 180
Appendix E Scanner Electronic Box • After a few seconds, the Installation & Utilities screen appears, as follows. • Click Continue. After a few seconds, the Scanner Serial Number screen is displayed. • Enter the scanner serial number. The number is displayed in one of the following locations: on the calibration slide, or below the barcode on the label on the back of the scanner.
Page 181
Installing Scanner Electronic Box The scanner automatically runs the Diagnostic tests. If all the tests passed, the following window is displayed. • Click Yes. • As a precaution, we recommend that you back up the newly created tables. The following dialog box is displayed. •...
Page 182
Appendix E Scanner Electronic Box The scanner automatically runs the Diagnostic tests. If all the tests pass, the following window is displayed. Click Yes. As a precaution, we recommend that you back up the newly created tables. The following dialog box is displayed. Select the folder in which you want to save the parameters Click Save to Folder to save the parameters.
Page 183
Installing Scanner Electronic Box After the tables are copied, a message window is displayed confirming the installation has been successfully completed. Click Done to return to the main menu. Results of the installation procedure are written to the Install&UtilResultFile.txt file in the log folder. See Section 8.6 on page 96 for an explanation of this file.
Appendix E Scanner Electronic Box Troubleshooting for Electronic Box Replacement Description and Solution Problem on page... Serial Number Mismatch Serial Number Mismatch (second time) Diagnostics Check Failure (Macintosh) Diagnostics Check Failure (PC) Calibration Slide Incorrectly Placed Optics Check: Out of Tolerance E.3.1 Serial Number Mismatch Problem If there is a mismatch between the serial number on the scanner label,...
Troubleshooting for Electronic Box Replacement E.3.2 Serial Number Mismatch (second time) Problem If the number entered still does not match, the following message window appears on the screen requesting insertion of the scanner parameters backup CD. Click No Backup. The following message is displayed. Click OK.
Page 186
Appendix E Scanner Electronic Box Click No Backup. The following window is displayed. Follow the instructions on the screen and click Proceed. Solution The application starts automatically to create new scanner parameters.
Troubleshooting for Electronic Box Replacement E.3.3 Diagnostics Check Failure (Macintosh) Problem If any of the scanner hardware does not pass the diagnostics check, a fail message appears in the Diagnostics Checks window. Solution Click Continue to continue with the installation program. If the Continue button is disabled, click Quit to exit to the main screen, and contact your service center.
Appendix E Scanner Electronic Box E.3.4 Diagnostics Check Failure (PC) Problem If any of the scanner hardware fails the diagnostics check, the following window and message appear: Solution Click Continue to continue with the installation program. Click Quit to exit to the Main Installation menu, and contact your service center.
Troubleshooting for Electronic Box Replacement E.3.5 Calibration Slide Incorrectly Placed Problem The scanner verifies that the calibration slide has been placed on the scan carriage, and is inserted correctly. If this test fails, a message repeats the request to place the calibration slide correctly. Solution Follow the instructions in the screen, and click Proceed.
Appendix E Scanner Electronic Box E.3.6 Optics Check: Out of Tolerance Problem During the Optics check, an Out of Tolerance message is displayed. Solution In this case, the previously generated tables remain intact. New tables will not be generated. Click Quit to return to the main window. Repeat your scan using the previously generated parameters.
Page 192
Appendix F Language Support The first time you launch the application that supports different languages, the following window opens: From the drop-down box, select the preferred language (the default language is English), and click OK; the following window is displayed. To change the default interface language in an application that supports different languages, from the Language menu, select the language you wish to have as a default language.
Page 194
Appendix G Part Numbers Part Name Part No. 510K1R588 Installation Kit (required for installation) includes: • Power cable, 3 m (American Cord) 199A03110 • FireWire cable, 6-pin molded IEEE1394, 6P/6 199A02160C • Installation & Maintenance Guide (includes the following items:) 501L3R393A •...
Page 195
Part Name Part No. 513K3R034 oXYgen Training Package includes: • User Guide (English) 399Z1P555 • Web based Application Training CD-ROM (Mac) • English 501V3R394 • French 501V3R395 • German 501V3R396 501R49738 Oil Mounting Kit (optional) 501R49740 iQsmart DOT Kit Part Name - oXYgen LE-Windows Kit Part No.