Advertisement

Air Compressor
Operation Manual
ZC350
Before operation be familiar
with the operation manual first

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZC350 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zephyr ZC350

  • Page 1 Air Compressor Operation Manual ZC350 Before operation be familiar with the operation manual first...
  • Page 2: Table Of Contents

    Contents Brief Description……………………… Page 1 General View and Main Components… Page 1 Technical Specification……………….. Page 1 Preparation before Starting…………… Page 2 Operation and Adjustment……………. Page 2 Cautions………………………………. Page 3 Maintenance…………………………… Page 3 Trouble Shooting……………………… Page 4 Parts Illustration………………………. Page 5 Parts List……………………………….
  • Page 3: Brief Description

    Outlet Valve Regulating Valve Pressure gauge Non Return Valve Drain Valve Wheel Air tank 10, Safety Valve 11, Fan Cover Technical Specification ITEM DATA Model ZC350 Power 2.2Kw/3HP Voltage 230V Frequency 50Hz Motor Rated Speed 2850 rpm Current Air Displacement 14.55...
  • Page 4: Preparation Before Starting

    Preparation before Starting Remove compressor from outer packaging DO NOT REMOVE TRANSIT PLUGS BEFORE FITTING THE WHEELS. Lie compressor on side to fit wheels and dampers Allow 5-10 minutes once compressor is upright before starting. Remove transit plugs and insert air filters supplied Insert oil breather plug supplied The ideal place to set the compressor should be...
  • Page 5: Cautions

    Cautions Never remove any connecting parts when the tank is under pressure. Never remove any electrical parts before isolating the electrical supply. Never adjust the pressure switch unnecessarily Always ensure that the electrical supply is sufficient for the compressor. Never use the electrical plug to start or stop the compressor. If the pressure switch isn’t working, switch off the machine immediately to reduce any long term damage.
  • Page 6: Trouble Shooting

    Trouble Shooting Trouble Possible Causes Possible Fix Motor unable (1) Fault in line, or voltage (1) Check the electrical supply to run, insufficient (2) Replace the cable running slow (2) Power cable to thin or too long (3) Repair or Replace or getting (3) Faulty pressure switch (4) Check and Repair...
  • Page 7: Parts Illustration

    Parts Diagram...
  • Page 8: Parts List

    Parts Illustration Description Description Bolt M6x55 Stator Cylinder head Rotor Cylinder head gasket Bearing 6202 Valve plate Wave washer D35 Valve plate gasket Electrical board Reed valve Electrical board switch Locating pins Electrical cover Cylinder Small guard Cylinder gasket Bolt M5x30 Piston ring Motor fan Oil seal...
  • Page 9: List Of Contents

    Operation Manual Wheel Kit Warranty Information SWP’s Zephyr range of air compressors are covered by a 12-months warranty period providing the unit has been serviced maintained and installed in accordance with SWP guidelines. All compressors must be installed in a large, well ventilated, dust free area and sheltered away from either rain or frost.

Table of Contents