Outlet Valve Regulating Valve Pressure gauge Non Return Valve Drain Valve Wheel Air tank 10, Safety Valve 11, Fan Cover Technical Specification ITEM DATA Model ZC350 Power 2.2Kw/3HP Voltage 230V Frequency 50Hz Motor Rated Speed 2850 rpm Current Air Displacement 14.55...
Preparation before Starting Remove compressor from outer packaging DO NOT REMOVE TRANSIT PLUGS BEFORE FITTING THE WHEELS. Lie compressor on side to fit wheels and dampers Allow 5-10 minutes once compressor is upright before starting. Remove transit plugs and insert air filters supplied Insert oil breather plug supplied The ideal place to set the compressor should be...
Cautions Never remove any connecting parts when the tank is under pressure. Never remove any electrical parts before isolating the electrical supply. Never adjust the pressure switch unnecessarily Always ensure that the electrical supply is sufficient for the compressor. Never use the electrical plug to start or stop the compressor. If the pressure switch isn’t working, switch off the machine immediately to reduce any long term damage.
Trouble Shooting Trouble Possible Causes Possible Fix Motor unable (1) Fault in line, or voltage (1) Check the electrical supply to run, insufficient (2) Replace the cable running slow (2) Power cable to thin or too long (3) Repair or Replace or getting (3) Faulty pressure switch (4) Check and Repair...
Operation Manual Wheel Kit Warranty Information SWP’s Zephyr range of air compressors are covered by a 12-months warranty period providing the unit has been serviced maintained and installed in accordance with SWP guidelines. All compressors must be installed in a large, well ventilated, dust free area and sheltered away from either rain or frost.
Need help?
Do you have a question about the ZC350 and is the answer not in the manual?
Questions and answers