Allstyle 4AC13018ASA1 Installation Manual

4ac 14* asa1 series r-410a condensing units

Advertisement

4AC 14* ASA1 SERIES
R-410a CONDENSING UNITS
ATTENTION, INSTALLER!
After installing the system, show the user how to turn off
electricity to the unit. Point out control and switch locations
for turning off electricity. Make sure the user understands
the importance of following all safety precautions, including
what could happen if they don't.
Keep the following documents in a safe, accessible location.
Tell the user where these documents are located:
Installer's Information Manual
Parts List
Warranty Information
While these instructions have been written as accurately
and thoroughly as possible, they may not cover every
system variation or contingency. Questions of interpretation
may arise. For more information, solutions to particular
problems or clarification, contact your local distributor or the
manufacturer.
WARNING:
to install comfort air conditioning appliances. Before performing any work on this equipment, the power supply
must be turned off at the household service box. Improper installation could void the warranty; create a hazard,
resulting in the possibility of damage, injury or death.
Individuals who install this equipment, must have the training and experience necessary
INSTALLATION GUIDE
ATTENTION, USER!
Your equipment installer should give you the important
documents listed above.
with these instructions, as it will be helpful in avoiding any
needless service costs or operational problems.
these instructions as long as you keep your equipment for
future reference. If any of the documents are missing or
illegible, contact your installer or equipment manufacturer
for replacement.
Throughout this manual, when we use the word "you" we
refer to the qualified service technician who is responsible
for application, installation, and service of your equipment.
While these instructions are addressed primarily to the
installer, useful maintenance information is included. Have
your installer acquaint you with the operating maintenance
requirements.
A
R
-410
You should become familiar
816080 B
Keep

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4AC13018ASA1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Allstyle 4AC13018ASA1

  • Page 1 4AC 14* ASA1 SERIES INSTALLATION GUIDE R-410a CONDENSING UNITS -410 ATTENTION, INSTALLER! ATTENTION, USER! After installing the system, show the user how to turn off Your equipment installer should give you the important electricity to the unit. Point out control and switch locations documents listed above.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION 1. GENERAL INFORMATION ..................2 SECTION 2. MEETING CODES ....................3 SECTION 3. DETERMINING CONDENSER LOCATION ............SECTION 4. REFRIGERANT PIPING CONNECTIONS ............. 4 SECTION 5. ELECTRICAL CONNECTION ................5 SECTION 6. REFRIGERANT CHARGE ..................SECTION 7. CHECKOUT PROCEDURE ..................SECTION 8.
  • Page 3: Section 2. Meeting Codes

    Height Length Width Model 4AC13018ASA1 16.50” 36.25” 31.25” 4AC13024ASA1 20.50” 36.25” 31.25” 4AC13030ASA1 20.50” 36.25” 31.25” 4AC13036ASA1 24.50” 36.25” 31.25” 4AC13042ASA1 24.50” 36.25” 31.25” 4AC13048ASA1 24.50” 36.25” 31.25” 4AC13060ASA1 28.50” 36.25” 31.25” 4AC14018ASA1 20.00” 36.25” 31.25” 4AC14024ASA1 20.00” 36.25” 31.25”...
  • Page 4: Section 4. Refrigerant Piping Connections

    A minimum clearance of 18” is required for service at Provide sufficient clearance from shrubs to allow adequate the control panel access. A 12” clearance is required air to pass across the outdoor coil without leaves or branches for the air inlet to the outdoor coil around the perimeter being pulled into the coil.
  • Page 5: Section 5. Electrical Connection

    Freq. Voltage Amps Circuit Fuse/ HACR Amperes Amperes Number Phase (Hz) (Volts) (FLA) Amperes Ckt. Bkr. (RLA) (LRA) 208/230 10.0 13.3 4AC13018ASA1 208/230 14.3 58.3 18.7 4AC13024ASA1 208/230 14.3 18.7 4AC13030ASA1 208/230 18.6 24.8 4AC13036ASA1 208/230 20.0 26.5 4AC13042ASA1 208/230 24.3...
  • Page 6: Section 6. Refrigerant Charge

    SUB-COOLING CHARGING METHOD WARNING: Casing or cabinet must be permanently grounded in accordance with National The sub-cooling charging method is to be used on units Electric Code or other applicable local codes. which have Thermostatic Expansion Valve (TXV) as the expansion device.
  • Page 7: Section 7. Checkout Procedure

    SECTION 7. CHECKOUT PROCEDURE SECTION 8. MAINTENANCE CHECKOUT PROCEDURE CAUTION: Be sure the unit disconnect is in Use the following list to see that nothing was over looked: the OFF position and that all electrical power to the unit is turned off before cleaning the system.
  • Page 8 Installer’s Information Manual Page 8...
  • Page 9: Section 9. Trouble-Shooting Chart

    SECTION 9. TROUBLE-SHOOTING CHART WARNING: Disconnect all power to unit before servicing. Failure to shut off power can cause electrical shock resulting in personal injury or death. SYMPTOM POSSIBLE CAUSE CORRECTION Unit will not operate • Power disconnected or loose connection •...
  • Page 10 Page 10 Installer’s Information Manual...
  • Page 11 NOTES: Installer’s Information Manual Page 11...
  • Page 12 Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specification without notice. Rev. 8/2015 Installer’s Information Manual...