Sunchaser Duo-Therm Classic 54812.041 Installation And Operating Instructions Manual

Roof mount rotary xl 558 series, classic 548 series

Advertisement

INSTALLATION
and OPERATING
INSTRUCTIONS
Cet appareil doit etre repare seulement par
un reparateur autorise. Modification de
I'appareil pourrait etre extremement dangereuse.
READ THESE INSTRUCTIONS CAREFULLY, KEEP FOR FUTURE REFERENCE.
A V I S :
et pourrait Causer mal ou mort.
19-1112-2

ROOF MOUNT

AIR CONDITIONER

Rotary XL (558 Series)
and Classic (548 Series)
QUICK START
MODELS
54812.041
55812.041
54815.041
54815.043
55815.041
C A U T I O N
M O D I F I C A T I O N O F T H I S A P P L I A N C E CAN B E
E X T R E M E L Y HAZARDOUS. A L W A Y S C O N S U L T
THE MANUFACTURER BEFORE MAKING CHANGES.
SHUR START
MODELS
54812.042
55812.042
54815.042
54815.044
55815.042
Form No. 19-1112-2 7-14-80

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Duo-Therm Classic 54812.041 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sunchaser Duo-Therm Classic 54812.041

  • Page 1: Roof Mount

    INSTALLATION and OPERATING INSTRUCTIONS ROOF MOUNT AIR CONDITIONER Rotary XL (558 Series) and Classic (548 Series) QUICK START SHUR START MODELS MODELS 54812.041 54812.042 55812.042 55812.041 54815.042 54815.041 54815.044 54815.043 55815.042 55815.041 READ THESE INSTRUCTIONS CAREFULLY, KEEP FOR FUTURE REFERENCE. C A U T I O N A V I S : Cet appareil doit etre repare seulement par...
  • Page 2 S P E C I F I C A T I O N S * For two units USE 5000 watt generator DUO-THERM TESTED UNDER ARI STANDARD 250-74 UL STANDARD 484 14” x 14” OPENING FROM ROOF VENT REMOVAL STANDARD 22.2 No. 0,46 and 119 Right Normally, roof mount air conditioners are installed where Left...
  • Page 3: Installation Layout

    INSTALLATION LAYOUT Fig. 4 AIR CONDITIONING UNIT Threaded Hole NOTE: The anchor bolts, supplied as standard equipment, will cover a range of 2 3/8" to 4 1/8" roof thickness. For roof thicknesses, other than the standard, special Bolt Kits can be obtained by Roof Flashing special order.
  • Page 4 Ceiling Template Installation: Open the plastic bag of Framing is required to provide adequate support and a mounting parts and use the Installation Layout on Page 3 smooth surface for sealing. Under no circumstances should for reference. the roof be constructed to create a low spot where water will accumulate.
  • Page 5 Mounting requires Install Air Box: (Reference Fig. 7) Control Box Installation: Fasten the control box to the four (4) wood screws (A); one (1) machine screw (B); and ceiling template with two blunt point screws (E). (See two (2) hex nuts (C) to install the air box. (Reference Fig.
  • Page 6 FOR COOLED AND DEHUMIDIFIED AIR set the thermo- NOTE: Shur-Start models have a delayed start kit installed. stat dial to the desired temperature. The warmest setting When the unit is turned on, the fan will start and in approxi- (WARM) on the dial is approximately 95 degrees; mately two (2) minutes, the compressor will start.
  • Page 7: Wiring Diagram

    WIRING DIAGRAM COMPRESSOR FACTORY WIRING - FIELD WIRING 115 V.A.C. 6 0 ~ If SHUR START ONLY I- CIRCUIT DIAGRAM Therm. GRD.
  • Page 8 DUO-THERM, Division of Motor Wheel Corp., LaGrange, Indiana 46761...

This manual is also suitable for:

Duo-therm classic 54815.041Duo-therm rotary xl 55815.041Duo-therm classic 54815.043Duo-therm rotary xl 55812.041Duo-therm classic 54812.042Duo-therm rotary xl 55812.042 ... Show all

Table of Contents