Adjustment value determination is effectuated using below val-
ues.
The adjustment values fulfill the conditions below, they are de-
termined as within specifications.
Adjustment value determination
AF_TEMP_AD: ATAD
ATAD: adjustment value of focus temperature A/D
(250<=ATAD<=893)
AF_WIDE: ZW
ZW: adjustment value of focus at zoom position wide
(–60<=ZW<=35)
AF_MID1: ZM1
ZM1: adjustment value of focus at zoom position middle1
(–90<=ZM1<=20)
AF_MID2: ZM2
ZM2: adjustment value of focus at zoom position middle2
(-78<=ZM2<=32)
AF_TELE: ZT
ZT: adjustment value of focus at zoom position tele
(–51<=ZT<=59)
3. AWB Adjustment
Camera
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
Adjusting method:
1. Set a distance of 0.5-1.0 cm between the pattern box and
the camera. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Pattern box
(color viewer)
2
)
Dsc Calibration
AWB Results:
1:
WB=261,551,607
CHECK=127,128,121
WB_ND=262,551,592
CHECK_ND=127,128,125
IR_TEMP_AD=438
IRIS_PWM1=222,208
IRIS_PWM2=198,195
IRIS_PWM3=184,178
IRIS_PWM4=174,168
IRIS_PWM5=157,149
MS=2084,1037
MS_M=1649,1476
MS_C=1425,1237
MS_C2=1161,1127
Fno_FOR_ISO=-1
SS_FOR_ISO=-1
YLEVEL_FOR_ISO=-1
When all of the AWB adjustment screen
is not displayed, use a scroll bar.
Adjustment value determination is effectuated using the
"CHECK", "CHECK_ND", "MS", "MS_M", "MS_C", "MS_C2",
"IRIS_PWM1", "IRIS_PWM2", "IRIS_PWM3", "IRIS_PWM4",
"IRIS_PWM5" and "IR_TEMP_AD" values. If
CHECK = wc0, wc1, wc2
CHECK_ND = wnc0, wnc1, wnc2
MS = ms1, ms2
MS_M = ms3, ms4
MS_C = ms5, ms6
MS_C2 = ms7, ms8
IRIS_PWM1 = s1, s2
IRIS_PWM2 = s3, s4
IRIS_PWM3 = s5, s6
IRIS_PWM4 = s7, s8
IRIS_PWM5 = s9, s10
IR_TEMP_AD = itad
the adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
wc0=128 ± 2, wc1=128 ± 2, wc2=150 ± 50
wnc0=128 ± 2, wnc1=128 ± 2, wnc2=150 ± 50
1200<=ms1<=4450, 240<=ms2<=2240,
980<=ms3<=2980, 820<=ms4<=2820,
700<=ms5<=2700, 570<=ms6<=2570,
470<=ms7<=2470, 360<=ms8<=2360
0<=s1<=255, 0<=s2<=255, 0<=s3<=255, 0<=s4<=255,
0<=s5<=255, 0<=s6<=255, 0<=s7<=255, 0<=s8<=255,
0<=s9<=255, 0<=s10<=255
ms2<ms8<ms7<ms6<ms5<ms4<ms3<ms1
s1>s2>s3>s4>s5>s6>s7>s8>s9>s10
250<=itad<=893
Adjustment values other than the above are irrelevant.
– 19 –
x
OK
Copy