Gas forced heater

Technical specifications

Table 1
Nominal heat output
Fuel Consumption
Fuel Orifice Port Size
Air flow temperature
Gas type
Gas category
Gas pressure
Air consumption
Rated voltage
Nominal power consump-
tion
Rated current
Type of Ignition
Noise level
Overheating Protection
Weight
Dimensions
Electrical protection class
Moisture protection class
For more detailed description of technical parameters and specifications please refer to our web-
site www.hyundai-hvac.com or ask from the official dealers of Hyundai.
ATTENTION!
The manufacturer reserves the right to change the set-list of the
device (including liquid and powder components) for different
supplies without prior notice. The changes either in no way influence
the basic technical parameters of the device or may improve them,
and also not violate the legislation or quality standards of the
countries of manufacture, transit and selling.
The changes in the set-list may result in changing of the weight
and dimensions of the device, but not more than by +\- 5-20%
(depending on the product category)
H-HI1-10-UI580 H-HI1-30-UI581 H-HI1-50-UI582
W
10000
kg/h
0,73
mm
0,74
oC
300
Propane/Butane
G30
mBar
300
3
m
/h
320
V/Hz
~220/50
W
30
A
0,14
piezo
dB
60
C
95
o
kg
3,8
mm
305x380x190
Class I
IPx0
30000
2,18
1,28
430
Propane/Butane
Propane/Butane
G30
700
650
~220/50
~220/50
70
0,32
piezo
63
75
6,1
360x475x225
360x580x225
Class I
IPx0
5.
50000
3,63
1,4
360
G30
1500
872
70
EN
0,32
piezo
65
95
6,8
Class I
IPx0

Advertisement