Page 2
No Disassembly No Touching Procedures Must be Followed. Beware of Electric Shock Do not disassemble Kaneka thin-film Do not shock the MODULES (e.g. by silicon photovoltaic module(s) (hereinafter stepping on it), as this may break the glass referred to as the MODULE(S)), as this part and cause malfunction, electric shock may cause fire, electric shock, and injury.
Page 4
G-SA060-002 2.Electrical Characteristics of MODULES PRODUCT:THIN-FILM SILICON PV MODULE MODEL: G-SA060 DATE: April 01, 2006 SPECIFICATION LISTS UNIT VALUE REMARK Performance at STC (stabilized) Nominal Power (Pmax) 60.0 Open Circuit Voltage (Voc) 92.0 Open circuit Voltage (Voc) at -10°C 101.2...
Page 5
G-SA060-002 3. Specifications subject to change without notice. 4. Under normal conditions, the MODULES may experience conditions that produce more current and/or voltage than reported at Standard Test Conditions. Accordingly, the values of Isc and Voc marked on UL Listed MODULES should be multiplied by a factor of 125% when determining component voltage ratings, conductor capacities, fuse sizes and size of controls connected to the MODULE output.
Page 6
G-SA060-002 3.Installation of the MODULES The assembly is to be mounted over a fire resistant roof covering rated for the application. 5 in/ft (127mm/305mm) required to maintain UL fire class rating. Artificially concentrated sunlight shall not be directed on the MODULE.
Page 7
G-SA060-002 Recommended mounting system for installation method 2 is “Solar Mount /S-5! PV Clamp Sets” made by UniRac, Inc. Install the mounting system as instructed by a installation manual of the mounting system. (Refer to installation manual provided by UniRac.) Then, fix the MODULES with the cramps (4 pairs or more per module).
Page 8
G-SA060-002 4.Connecting cables Use 14 AWG minimum, insulated for 90 ℃ minimum cables. Stranded Copper only. When connecting cables, push the plus and minus connectors against each other while twisting them until they are fully engaged. Plus cable connector: PV-KST3II UR (Multi-Contact USA)
G-SA060-002 Side frame Nut Star washer Flat washer Wire Lug Wire insert Hex bolt Set screw 1. Press a stainless steel nut with a star washer and a 10-32 thread into the ground holes (marked ‘GR’) on the back of frame. 2. Install a ground lug such as the shown ILSCO GBL-4DBT which is UL listed.
Page 10
G-SA060-002 7.Limitation See the Attachment A: Instruction for using G-type (UL grade).
Need help?
Do you have a question about the G-SA060 and is the answer not in the manual?
Questions and answers