Advertisement

NORTH STORM
4-in-1
AIR CONDITIONER

USER MANUAL

MODELS
NS–14B-AC
NS-14W-AC
1

Advertisement

Table of Contents
loading

Summary of Contents for North Storm NS-14B-AC

  • Page 1: User Manual

    NORTH STORM 4-in-1 AIR CONDITIONER USER MANUAL MODELS NS–14B-AC NS-14W-AC...
  • Page 2 INTRODUCTION Thank you and congratulations on your purchase of your North Storm Portable AC Unit. ™ PLEASE READ THIS MANUAL BEFORE OPERATING THIS APPLIANCE. WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, AN ELECTRIC SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety Awareness……………………………………………………....…………..4 Name of Parts……………………………….………………………....…….……..5 Accessories………………………………………………..………....……..……..6 Introduction to Panel and Remote Controller………………..………..………..7 Operation Introduction…………………………………………..……..………..9 Installation Explanations…………………………………………...…………….12 Maintenance Explanations………………………………………..…….………..14 Troubleshooting……………………………………………………...…………….. 15...
  • Page 4: Safety Awareness

    SAFETY AWARENESS ● Do not use the unit on a socket under repairs or not ● When moving the air-conditioner, always turn off and installed properly. disconnect the power supply, and move it slowly. ● Do not use the unit, follow these precautions: ●...
  • Page 5: Name Of Parts

    NAME OF PARTS SIDE VIEW 1. Rear Cover 2. Air Inlet 3. Front Cover FRONT VIEW 4. Operation Panel NORTH STORM 5. Castor REAR VIEW 6. Power Cord 7. Air Inlet 8. Drain Plug FIG. 1...
  • Page 6: Accessories

    ACCESSORIES SPEED TEMP+ MODE TEMP- TIMER POWER NORTH STORM Hot-Air Window Remote Main AC Unit Hose Connector Hose Connector Exhaust Hose Controller (Window End) (AC End) FIG. 2...
  • Page 7: Introduction To Panel And Remote Controller

    CONTROL PANEL TEPERATURE- OPERATION BUTTON MODE BUTTON HIGH LOWT IMER COOL DEHUMF HEAT POWER TEMP+ TEMP- MODE SPEED TIMER POWER TEPERATURE+ SIGNAL RECEIVER FAN SPPED TIMER BUTTON BUTTON WINDOW ADJUSTMENT ON/OFF BUTTON BUTTON FIG. 3...
  • Page 8: Remote Controller

    REMOTE CONTROLLER POWER : On/Off switch MODE : Mode selector SPEED TEMP+ MODE TIMER : Hourly programming TEMP- TIMER SPEED : Fan speed selector POWER TEMP+ : Temperature selector up TEMP- : Temperature selector down FIG. 4...
  • Page 9: Operation Introduction

    OPERATION INTRODUCTION Before starting operations in this section: FIG. 5 FIG. 5a Fig.6 Fig.6a 1) Find a place where there is power supply nearby. 2) As shown in Fig.5 and Fig.5a, install the exhaust hose, and adjust the window position well. 3) Insert the power cord into an Fig.7 FIG.
  • Page 10 OPERATION INTRODUCTION CONT. Before using Dehumidifying Operation Notice: Operation temperature range: ● Press the “Mode” button till the “Dehumidify Indicator Check up whether the exhaust hose has been Lamp” blinks mounted properly. ● Set the selected temperature to current room temperature minus 2F0.
  • Page 11 OPERATION INTRODUCTION CONT. ● ON time can be regulated at any time in 0-24 hours. CONTINUOUS DRAINAGE Timer OFF setting ● When you plan to leave this unit unused for a long time, ● When the air-conditioner ON, press “Timer” button and please remove the rubber blockage from the drainage select a desired OFF time through the temperature and hole at the bottom of unit, and connect a drain hose to...
  • Page 12: Installation Explanations

    INSTALLATION EXPLANATIONS Installation Explanations: ● A removal air-conditioner shall be installed in the flat and empty place all around. Don’t block the air outlet, and the required distance around should be at least 30cm. (See Fig.7) ● Should not be installed in dry cleaner. ●...
  • Page 13 INSTALLATION EXPLANATIONS Window Slider Kit Installation The installation manner of window slider kit is mostly in “horizontal” and “vertical”, No much difference in actual process. As shown Fig. 9 and Fig. 9a, check the min. and max. size of the window. Internal Tank Water Full Alarm Function The inner water tank in the air-conditioner has one water level safety switches, it controls water level.
  • Page 14: Maintenance Explanations

    MAINTENANCE EXPLANATIONS Declaration: 1) Before cleaning, be sure to disconnect the unit from any electric supply outlet; 2) Do not use gasoline or other chemicals to clean the unit; 3) Do not wash the unit directly; 4) If the conditioner is damaged, please contact the dealer or repair shop. Air Filter If the air filter becomes clogged with dust/dirt, the air filter should be cleaned once every two weeks.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Troubles Possible Causes Suggested Remedies Troubles Possible Causes Suggested Remedies Water full Dump the water out The doors or Make sure all the indicator lamp of the water tank. windows are windows and doors blinks, and not closed. are closed. water tank is There are heat Remove the heat...
  • Page 16 TROUBLESHOOTING CONT. Troubles Possible Causes Suggested Remedies Troubles Possible Causes Suggested Remedies 3. Auto Power- Heating Restart the unit at 5. E0 Code Room Replace room Off in heating protection, enough lower room temperature temperature sensor mode when the temperature. sensor failed (the unit can also temperature at...
  • Page 17 Due to ongoing product development we reserve the right to change the product specifications and documentation without notice. For more information: ENERGYWISE SOLUTIONS PO BOX 4681 LOGAN, UT 84323 877- 891-7333 northstorm.com NORTH STORM...