* To go to the service mode, the data at the E
2
PROM's addresses 00H thru 03H are read. If the data are not as
given below, the E
2
PROM is initialized according to the table below.
Address :
Data
00H :
23H
01H :
20H
E
2
PROM item
Data adjustable range
(00H)
––––––––––
(01H)
––––––––––
(02H)
––––––––––
(03H)
––––––––––
R CUT OFF
0 ~
G CUT OFF
0 ~
B CUT OFF
0 ~
G DRIVE
0 ~
B DRIVE
0 ~
50Hz V-AMP
0 ~
50Hz V-LINEARITY
0 ~
50Hz S-CORRECTION
0 ~
50Hz V-PHASE
0 ~
50Hz H-PHASE
0 ~
V-BLK ST 50
0 ~
V-BLK SP 50
0 ~
60Hz V-AMP
0 ~
60Hz V-LINEARITY
0 ~
60Hz S-CORRECTION
0 ~
60Hz V-PHASE
0 ~
60Hz H-PHASE
0 ~
60Hz V BLK ST
0 ~
60Hz V BLK SP
0 ~
SECAM R-Y
0 ~
SECAM B-Y
0 ~
SUB-CONTRAST
0 ~
SUB-BRIGHT
0 ~
SUB-COLOUR
0 ~
SUB-TINT
0 ~
SUB-SHARPNESS
0 ~
Y SUB-CONTRAST
0 ~
DT PAL TV/AV
0 ~
DT SECAM TV/AV
0 ~
DT NTSC TV/AV
0 ~
DT B/W TV/AV
0 ~
V-MUTE
A/V 2
NVM With all the adjustments complete, do not change the data of addresses 00H thru 03H. Other-
wise the E
2
PROM will be initialized when the AC power is turned on.
*1 : These data are additionally adjusted for 60Hz based on the 50Hz settings.
*2 : Unless otherwise specified, these data are fixed and need no adjustment.
*4 : Only 0 through 5 must be used in changing the data.
02H :
13H
03H :
61H
Data initial value
Remarks
23H
20H
13H
61H
255
0
255
0
255
0
255
127
255
127
127
58
31
16
127
67
*1
7
5
–3
31
7
+5
63
58→63 (50Hz)
127
25
127
59
31
14
127
74
7
2
31
12
63
60→63 (60Hz)
127
20
15
10
15
6
255
255
255
127
255
110
127
70
63
28
31
18
7
2/2
7
4/4
7
2/2
7
2/2
ON/OFF
OFF
1/2
1
5-1
INITIAL SETTINGS OF CHANNEL SELECTION DATA
(1) Make an entry of MCL1 in the service mode in order to set the following channel selection data to the
E
2
PROM. And select the POS1 channel. (An MCL2, -3 or -4 input makes different settings.)
POS
RECEPTION FREQ (MHZ)
1
48.25
2
62.25
3
77.25
4
175.25
5
182.25
6
183.25
7
191.25
8
196.25
9
210.25
10
224.25
11
471.25
12
487.25
13
503.25
*1
14
575.25
15
599.25
*1
16
621.25
17
639.25
18
703.25
19
735.25
20
767.25
*2
*4
(1) The following key-in data have been factory-set for the E
SKIP
*2
AFT
C-SYSTEM
S-SYSTEM
LAST POWER
LAST TV/AV
*2
DIGIT
*2
*2
LANGUAGE
*2
BLUE BACK
*2
LAST POS
LAST FB POS
VOLUME
CONTRAST
COLOUR
BRIGHTNESS
TINT
SHARPNESS
S-SYSTEM
POS
RECEPTION FREQ (MHZ)
B/G
21
815.25
B/G
22
855.25
D/K
23
855.25
B/G
24
55.25
B/G
25
83.25
D/K
26
183.25
D/K
27
193.25
D/K
28
471.25
B/G
29
477.25
B/G
30
693.25
B/G
31
885.25
I
32
112.25
B/G
33
168.25
B/G
34
FREE
B/G
35
294.25
36
463.25
D/K
37
FREE
B/G
38
647.25
I
39
663.25
B/G
40
679.25
FACTORY SETTING
2
PROM.
Item
Setting
OFF
ON
AUTO
B/G
ON
TV
1DIG
THAI
ON
1
1
MIN
MAX
CENT
CENT
CENT
CENT
5-2
S-SYSTEM
B/G
I
B/G
B/G
B/G
B/G
B/G
B/G
B/G
B/G
B/G
B/G
B/G
B/G

Hide quick links: