SUPREME heatseeker nova User Manual

Inverter

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the heatseeker nova and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SUPREME heatseeker nova

  • Page 2: Table Of Contents

    Index Index Index Heatseeker Nova Heatseeker Nova Inverter Heat Pump Inverter Heat Pump 1. GENERAL INFORNMATION 6. OPERATION Introduction to Heatseeker Nova Controller Overview 6.2.1 Consumer and Safety Infornmation Start 6.2.2 Mode Controls 2. SPECIFICATIONS 6.2.3 Water Temperature Settings 6.2.4...
  • Page 3: General Infornmation

    1.1 Introduction to Heatseeker Nova EARTHING Supreme Heating, 2015 SPASA Australia Awards of Excellence winner, is proud to include the Heatseeker Nova inverter heat CONNECT THE GROUND WIRE BEFORE OPERATION. pump in it’s range. Chosen by an expert panel of judges from...
  • Page 4: Technical Speci Cations

    2. Speci cations 2.2 Dimensions 2.1 Technical Speci cations MALFUNCTION SIDE DISCHARGE DIMENSIONS ERROR REASON SOLUTION MODEL CODE A Length B Depth C Height 10kW SHEATPUMP10CSI 1010mm 355mm 560mm 13kW SHEATPUMPNI13kW 1065mm 360mm 775mm 17kW SHEATPUMPNI17kW 1065mm 360mm 775mm 21kW SHEATPUMP21CSI 920mm 1085mm...
  • Page 5: Installation And Connection

    3. Installation and Connection 3.3 DISTANCE FROM YOUR SWIMMING POOL The heat pump is usually installed within a perimeter area 3.1 Installation Safety Notes extending 7.5 m from the swimming pool. The greater the distance from the pool, the greater the heat loss in the pipes. As the pipes The factory supplies the heat pump only.
  • Page 6: Typical Arrangement

    3.6 ADJUSTING THE BYPASS 3.4 CHECK-VALVE INSTALLATION HEATSEEKER NOVA HEAT PUMP - BACK AUTOMATIC DOSING AUTOMATIC DOSING IF AUTOMATIC DOSING EQUIPMENT FOR IF AUTOMATIC DOSING EQUIPMENT FOR CHLORINE AND ACIDITY (pH) IS USED- CHLORINE AND ACIDITY (pH) IS USED- THIS EQUIPMENT MUST BE FITTED IN THE PIPING...
  • Page 7: Electrical Connection

    Use the following procedure to adjust the bypass: Open all three valves completely Slowly close Valve 1 until the water pressure is increased by approximately 100 to 200g Close Valve 3 approximately half-way to adjust the gas pressure in the cooling system If the display shows "ON"...
  • Page 8: Condensation

    A quality Supreme Heating Heatseeker Diamond Pool Cover & Roller A quality Supreme Heating Heatseeker Diamond Pool Cover & Roller System can dramatically reduce the required heat up time.
  • Page 9: Electrical Wiring

    5. Electrical Wiring ATTENTION THE FOLLOWING ELECTRICAL WIRING DIAGRAMS ARE ONLY FOR YOUR REFERENCE, PLEASE CONSULT A SUPREME HEATING REPRESENTATIVE FOR MORE INFORNMATION. DISCONNECT: A disconnect means (circuit breaker, fused or un-fused switch) should be located within sight of and readily accessible from the unit.
  • Page 10: Operation

    ERROR REASON SOLUTION 6.1 CONTROLLER OVERVIEW MODEL CODE Product Description Discharge SHEATPUMPDCVI26 Heatseeker Nova 26kW Inverter Heat Pump Top Discharge MODE / SETTINGS DOWN HEATING HEAT WHEN IN OPERATION- THE LIGHT WILL BE ON WHEN DEFROSTING- THE LIGHT WILL FLASH...
  • Page 11: Checking The Time

    6.1.5 CHECKING THE TIME 6.1.8 SETTING THE AUTOMATIC STOP TIME CHECK THE CURRENT TIME SETTINGS SET THE AUTOMATIC STOP TIME OVERVIEW: STEP 1 Once the Automatic Start Time is saved, the screen will enter into the “Automatic Stop Time” interface. STEP 1 STEP 2 Press...
  • Page 12: Heat Pump Modes

    8. Troubleshooting 7. Heat Pump Modes 8.1 Error Code Displayed on LED Controller 7.1 SILENT MODE MALFUNCTIONS MALFUNCTION ERROR ERROR REASONS REASON SOLUTIONS SOLUTION When operating in Silent Water Inlet water temperature Mode, the heat pump will PP01 The sensor in open or short Check or change the sensor Sensor Failure Stop...
  • Page 13 8.2 Other Malfunctions and Solutions- No LED Display MALFUNCTION ERROR REASONS SOLUTIONS Communication Failure EE08 1. Insu cient Wire 1. Check the wire MALFUNCTION OBSERVING MALFUNCTIONS ERROR REASON REASONS SOLUTION SOLUTIONS Between Controller and Connection connection. Converter Board 2. Controller failure 2.
  • Page 14: Maintenance

    0-30A Real testing value NOTES When the Heatseeker Nova heat pump stops running for 30 seconds, the water pump will shut o automatically (in the case of an independant system). The LED controller can operate the water pump by connecting an additional cable between the pump and the “PUMP”...
  • Page 15: Warranty Agreement

    Aqua-Gen 3D Ltd’s reasonable opinion a defect is caused by: satis ed. Supreme Solar Pty Ltd will not be liable Automatic Controller, a one (1) year fair wear and tear;...
  • Page 16 Notes Notes supremeheating.com.au supremeheating.com.au...

Table of Contents