8-4 Poor cooling in Freezer compartment
No
1-. Unplug connector from
1
2-. Check resistance between wires
Blue/White to Blue/White.
<Drawer Model>
<Swing Model>
The sensor is determined by
the temperature.
For example, 23
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open the freezer door and Check the air
flow.
4
Check the air temperature.
Cold or not ?
Checking flow
CON7
.
indicates -4°F.
Result & SVC Action
Temperature
-22°F
-13°F
-4°F
5°F
14°F
23°F
32°F
Status
Windy
No windy
Status
Cold
Not cold
30
Result
°C
40
°C
30
°C
23
°C
17
°C
13
°C
10
°C
8
SVC Action
Go to the 4
Check the F Fan motor
(Go to the 5)
SVC Action
Explain to customer
Check the Compressor
And sealed system