Charging Trouble - LG KC560 Service Manual

Table of Contents

Advertisement

5.3 Charging trouble

Check Points
- Connection of TA (check TA voltage 5.1V)
-Charging Current Path component voltage drop
- Battery voltage
1 Charging method : CC-CV
2 Charger detect voltage : 4.0 V
3 Charging time :
2h 50m
4 Charging current :
434 mA
5 CV voltage : 4.2 V
6 Cutoff current :
107 mA
7 Full charge indication current (icon stop current) :
8 Recharge voltage : 4.15 V
4.2V~3.78V
_EOC
CHG_EN
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
107 mA
3.78V~3.68V
2V62_VIO
2V62_VIO
VUSB_USB
VCH G
_PPR
R242
TP1
100K
C653
C654
1u
1u
3.68V~3.58V
U204
ISL9221
13
PGND
1
VDC
12
VDC_BYP
2
VUSB
11
BAT
3
_PPR
10
USB_BYP
4
_CHG
9
IVDC
5
_EN
8
GND
6
IMIN
7
IUSB
R243
5.1K
- 65 -
5. TROUBLE SHOOTING
3.60V~3.50V
VB AT
OVP_ VCH G
OVP_VUSB
TP2
R246
R244
R247
18K
15K
1u
(1%)
(1%)
LGE Internal Use Only

Advertisement

Table of Contents
loading

Table of Contents