Advertisement

Operating & Installation Manual
HAMLET
Hardy 4 & 5 Stoves
5
Hardy
pictured
PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE
Rev 02
August 2011
BK137
Part No. AFS1587

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hardy 4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hamlet Hardy 4

  • Page 1 Operating & Installation Manual HAMLET Hardy 4 & 5 Stoves Hardy pictured PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE Rev 02 August 2011 BK137 Part No. AFS1587...
  • Page 2 Should you have any questions about our Hamlet stoves that are not covered by this manual, please contact the Arada retailer in your area, or call our technical support department on 0844 847 5107.
  • Page 3: Table Of Contents

    Over Firing & Chimney Fires Final Check Ash Removal Building Control Consent Checklist Air Inlet Controls (Primary/Air wash) Fuel Retainer Multi Purpose Operating Tool Main Fire Door Handle OPTIONAL EXTRA/ACCESSORIES SPARE PARTS LIST 30-31 GUARANTEE 32-33 FACTORY CHECK LIST Hamlet Stoves...
  • Page 4: Warning Notice

    MUST NOT BE BURNED IN THIS APPLIANCE BITUMINOUS HOUSE COAL SHOULD NEVER BE USED IN YOUR STOVE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE. IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0845 601 4406 www.solidfuel.co.uk Hamlet Stoves...
  • Page 5: Introduction

     Avoid upper body/top heavy bending. Do Hamlet stoves are also fitted with an „air wash‟ not lean forwards or sideways when so called because it provides a curtain of high handling the fire speed pre-heated air behind the glass to help ...
  • Page 6: Check List

    CHECK LIST Inside the appliance body you should find the following: Hamlet Hamlet Part Description & Visual Aid (not to scale) Hardy 4 Hardy 5 1. Fuel Retainers 2. Throat Plate 3. Flue Spigot 102mm 102mm ( 4" ) ( 4" ) 4.
  • Page 7: Data Plate Information

    Data Plate Location Data Plate Information Please Note:- All Hamlet stoves are fitted with a data plate located on the bottom right hand side of the stove. The data given is on the output and performance of the stove. Hamlet Stoves...
  • Page 8: Technical Data

    TECHNICAL DATA Hamlet Hamlet TECHNICAL DATA Hardy 4 Hardy 5 Nominal Heat Output (Kw) Efficiency Nett (%) Height (mm) ‘A’ Width (mm) ‘B’ Depth (mm) ‘C’ Height to Centre of Rear Flue (mm) ‘D’ Depth From Back To Centre Of Flue (mm) ‘E’...
  • Page 9: Installation

    There must always be a permanent means of ASBESTOS providing air for combustion into the room in which All Hamlet stoves contain no asbestos in their the stove is installed. A permanent vent with a total manufacture or construction. If there is a possibility free area of at least 550mm²...
  • Page 10: Fitting The Flue Outlet & Hotplate

    Building Regulations and BS 7566: Parts 1 to 4. poor fuel consumption. Note: Refer to BS EN 15287-1:2007 for the design installation and commissioning of Chimneys. Hamlet Stoves...
  • Page 11: Flues & Chimneys

    ODPM website at www.hetas.co.uk www.safety.odpm.gov.uk/bregs/brads.htm. Details on the relevant Building Regulations and BS British Standards are given in the “ General Precautions” section of these instructions. Chimneys should be as straight as possible. Horizontal runs should be avoided except where Hamlet Stoves...
  • Page 12 Minimum 150mm (6”) Diameter Flue Maximum 150mm (6”) Horizontal Flue Section Soot Door Fire Retardant Rope Packing Maximum 100mm (4”) Brick Up Aperture Fill Void TYPICAL REAR FLUE OUTLET (as per BS 8303-1) Hamlet Stoves...
  • Page 13 And BS 7566 Part 1 to 4 PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES Combustible Register Thick (Plan View Of Steel Register Plate, 1.5mm Plate. Minimum ) Minimum 1.5mm Thick Steel. TYPICAL TOP FLUE OUTLET (as per BS 8303-1) Hamlet Stoves...
  • Page 14: Co Alarm

    Building regulations require that whenever a new or replacement fixed solid fuel or wood / biomass The Hamlet Stoves use firebox liner appliance is installed in a dwelling a Carbon panels to the sides and back. The throat plate sits Monoxide Alarm must be fitted in the same room on top of the sides and rear panels.
  • Page 15: Fitting The Grate

    Please see the instructions below on grate assembly. Grate The grates in the Hamlet stoves, comprise of a series of reciprocating cast iron grate bars, seated Fig. 3. Liners Inserted on a pivoted „comb‟. All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked „H‟...
  • Page 16: Final Check

    Checklist ( Page17 ) must be checked and completed in full by the installer at the time of installation. Please answer all questions as fully as possible. Hamlet stoves cannot be held responsible for the chimney or installation. Hamlet Stoves...
  • Page 17: Building Control Consent Checklist

    I/We the undersigned confirm that the above details are correct. In my opinion, these works comply with the relevant requirements in part J of Schedule 1 of the Building regulations. Print name and title…………………………………………………………………..Profession………………………………….. Capacity……………………………………………………………………………...Telephone No. …………………………….. Address………………………………………………………………………………………………..Postcode………………….. Signed………………………………………………………………………………..Date………………………………………... Registered member of..(e.g. Gas Safe ( , OFTEC, HETAS, NACE, NACS) CORGI Hamlet Stoves...
  • Page 18: Service & Maintenance

    NACS chimney engineer who will up heat slowly to gradually cure paint. provide a Certificate Of Chimney Sweeping. Note: Use genuine Hamlet touch up spray as The whole flue way including the outlet must be some swept at least twice per burning season.
  • Page 19: Summer Storage / Non Usage

    Please Note  Lift the fire door up off the hinges. Images fig 6 & 7 are for visual reference only and may differ slightly from your stove.  Drop one washer on the top and bottom Hamlet Stoves...
  • Page 20: Fire Door Rope Replacement

    Refit the door assembly back onto the stove; carefully lift the door over the hinge and slot into place. Fig. 8. Rope Replacement Rope Gasket Joint Fig. 9. Air wash cover and fixings Fig. 10. Lining Up Gasket Rope Hamlet Stoves...
  • Page 21: Primary Air Slider Inspection / Cleaning

    Clean the air slots within the door casting and slider plate.  Replace the slider and refit the control knob See image below. Fig. 11. Positioning The Glass Fig. 12. Tightening The Glass Clip Rear of Slider fitted into the door Hamlet Stoves...
  • Page 22: Service Record

    Company Work Carried Out Signature Should you have any questions about your Hamlet Signature stove that are not covered in this manual please contact your Hamlet dealer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits so they can complete the service record chart.
  • Page 23: Operating Instruction

    WARNING : NEVER BURN LIQUID FUELS IN UNDERSTOOD THESE INSTRUCTIONS YOUR STOVE. BEFORE LIGHTING THE FIRE. PLEASE CONTACT : The Manufacturer ALWAYS WEAR SUITABLE PROTECTIVE FIRE For Further Details & Advice On The GLOVES WHEN REFUELLING YOUR STOVE. Use Of Other Fuels. Hamlet Stoves...
  • Page 24: Burning Wood

    Approved Document J This effect can be minimised by burning hard for a Section 1, Paragraphs 1.20 & 1.23 for guidance short period, 15 to 20 minutes, twice a day. Hamlet Stoves...
  • Page 25: Riddling The Grate

    OPERATING INSTRUCTIONS RIDDLING GRATE OVER FIRING & CHIMNEY FIRES The Hamlet Hardy range of stoves is provided with a DO NOT over fire your appliance. Using flammable riddling grate mechanism to aid ash removal and to liquids or too much wood or firing the stove at max- ensure complete combustion of the available fuel.
  • Page 26: Air Inlet Controls (Primary/Air Wash)

    PRIMARY AIR Air enters the appliance through the control on the bottom of the fire door. The Hardy 4 & 5 has a single control knob which slides left to right. Sliding the knob to the Right, See Fig.13, will increase the amount of air intake to the stove.
  • Page 27: Multi Purpose Operating Tool

    AIR WASH / PRIMARY CONTROL TOOL KNOBS Your Hamlet stove is supplied with a multi purpose The operating tool can also be used to adjust the operating tool, used for adjusting the air inlet con- air wash and primary air control knobs. Use the...
  • Page 28: Main Fire Door Handle

    OPERATING INSTRUCTIONS MAIN FIRE DOOR HANDLE A stove mitten is supplied with your Hamlet Signature stove, this is provided for the operation of the fire door handle whilst the stove is in use. Care must be taken when opening and closing the fire door as any surrounding areas of the stove will be very hot.
  • Page 29: Optional Extra/Accessories

    OPTIONAL EXTRA / ACCESSORIES Visual Aid Hamlet Hamlet PART DESCRIPTION (not to scale) Hardy 4 Hardy 5 Aerosol Touch Up AFS 101a AFS 101a Paint Add In Slab AIB 7 AIB 0 Boiler * Floor Fixing Kit AFS1135 AFS1135 NOTE :- * Separate instructions are included for all Add-In boiler installations.
  • Page 30: Spare Parts List

    SPARE PARTS LIST Hamlet Hardy 4 Hamlet Stoves...
  • Page 31: Spare Parts List

    SPARE PARTS LIST Hamlet Hardy 5 Hamlet Stoves...
  • Page 32: Guarantee

    FREE OF CHARGE as long as the When you buy an Hamlet stove, you are not stove has been installed according to this only buying a first class appliance you are...
  • Page 33 Firebox liner panels, fuel retainer, throat plate, door rope, door glass, grate or grate bars and gaskets are not covered by the guarantee. The use of non Hamlet replacement parts will invalidate your warranty. For full details, contact your local Hamlet retailer. All guarantees are in addition to your statutory rights.
  • Page 34: Factory Check List

    Final Factory Check list Stove Model …………….……………… Serial No. ……………………………….. I’ve checked it Quality / Finish Parts and its O.K ! Grate Bars Flue Outlet Assembled By……………………. Hot Plate Fuel Retainer Checked by……………………….. Firebox Liners Throat Plate Door Catch/Nickel Door Handle Ash Pan Adjusting Feet x 2 Operating Tool...

This manual is also suitable for:

Hardy 5

Table of Contents