TROUBLE SHOOTING
TROUBLE SHOOTING
lights indication
power time run
Sensor is
shorted out
or opened
circuit
Sensor is
shorted out
or opened
circuit
Indoor fan
motor don
t feed back
Data error
or no
EEPROM
Air Conditioner
Air Conditioner
reasons
ways and means
Check the sensor of
indoor ambient
temperature
resistance value is 0
or
,the sensor is
abnormal.
Check the sensor of
indoor coil pipe
the resistance value
is 0 or
is abnormal.
check whether indoor motor
has 80~170V voltage, if it
has, wiring board is normal,
then
check
optical SCR is good, replace
it if it is has flaw; else check
whether there are something
wrong with connecting line
indoor fan motor cpacitor
and coil assembly
Check whether the
EEPROM is installed
properly
9
solutions
if the
Change the
sensor
if
,the sensor
Change the
sensor
Change the
whether
the
capacitor or
optical SCR
connecting
line or
indoor PCB
Change the
EEPROM