Samsung SMH9151S Service Manual page 20

Hide thumbs Also See for SMH9151S:
Table of Contents

Advertisement

4. Troubleshooting
Weight Sensor
Error
Gas Sensor Error Case (E-1X)
Code
E-31
Open (When value of HEX is above "FF" for 5 seconds)
E-32
Short
In case the initial value of HEX is under "14" for 30
E-33
seconds while a weight sensor in operation .
In case the initial value of K calculated by a weight
E-34
sensor is above and under "±28" as value of HEX .
E-35
In case the value of A is "-" as a weight sensor calculates .
E-36
In case the door opens during sensor cooking .
Easy/Ph Sensor
Error
Easy/PH Sensor Error Case (E4)
Code
E-41
Open
E-42
Short
E-43
T1 Max Time Error
E-44
Dry Up
E-45
Cooling Error (3minutes)
E-46
Primary Open Error(3minutes)
E-47
The door opens during cooking
Humidity Sensor
Error Code
Humidity Sensor Error Case (E-6X)
E-61
Open
E-62
Short
E-63
T1 Max Time Error
Others
Error
Others (E-0X, Letter)
Code
-SE-
Key Short Error (10 seconds)
E-02
Cooking Time Setting Over Error (MWO)
E-03
Cooking Time Setting Over Error (Grill)
Cooking Time Setting Over Error
E-04
(Convection)
Cooking Time Setting Over Error
E-05
(Combination)
It fails to sense that the swing heater has
E-06
stopped for 20 seconds during cooking .
Check Sensor .
Cancel the present mode and
restart from the begining .
Solution
Check Sensor .
Insert food and restart .
Remove moisture from sensor and restart .
Check Sensor .
Cancel the present mode and restart from the
begining .
Check Sensor .
Solution
Turn off set and restart .
Check each mode's setting time .
Check Swing heater's motor and connector .
20
Solution
Solution
Page
21 Page
22 Page
25 Page
26 Page
Page
21 Page
22 Page
23 Page
23 Page
26 Page
21 Page
26 Page
Page
21 Page
22 Page
23 Page
Page
24 Page
30 Page
34 Page

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smh9151beSmh9151be/xaaSmh9151ste

Table of Contents