10)OSD display [ON SCREEN DISPLAY]
Option
"YES", "NO" or "LIMITED" (loop enabled)
"LIMITED" is looped only in case of need (destination).
Default
"YES"
Function
Key which may be enabled
(Example of the confusing
key)
Disabled key when setting
to not default
Remarks
11)Start mode [INPUT MODE START]
Option
"NORMAL" or "Input source 1 (input selection or channel)" . . . (loop enabled)
Default
"NORMAL"
Function
which kinds of input source or channel is decided when the power turning on.
NORMAL
Remarks
Example of option: "NORMAL"
"TVD (002TV)", "INPUT1", "INPUT2", "INPUT3", "HDMI1", "HDMI2", "HDMI3", "HDMI4".
12)Input fixed [INPUT MODE FIXED]
Option
"VARIABLE" "FIXED", "ACCTRL" or "AC/RCCTRL" (loop enabled)
Default
VARIABLE
Function
VARIABLE
FIXED
AC CTRL
AC/RC CTRL
Disabled key when setting
CHANNEL (+/-), DIRECT CHANNEL buttons, FLASHBACK, INPUT SELECT, TV/VIDEO, AUTO PRESET, MANUAL
to "FIXED"
MEMORY, i.LINK, DIRECTINPUTSELECT, ATV, DTV, EPG, RADIO etc. ...
Remarks
YES
: OSD is displayed
NO
: the following OSD is not displayed.
Registration, setting, adjustment menu, channel call, volume bar, and input select
LIMITED
: only a part of OSD (CH call: "New Information" etc. ...) is not displayed.
It is OK in the case that simple input select occure or the original state returns soon automatically.
When setting to "NO", the keys which is related to visibility of the screen and sound cannot be used.
STILL IMAGE, SCREEN DISPLAY, OFF TIMER, AV POSITION, BRIGHTNESS SENSOR, SCREEN SIZE
SELECT, AUTO PRESET, MANUAL MEMORY, IMAGE SELECT, SOUND SELECT, LANGUAGE, Closed caution
* Disabled keys dependeds on the models.
When setting to "NO",
ON TIMER (Watching reservation) is cleared.
OFF TIMER "SLEEP" is cleared.
* These items does not exist according to the model.
When setting to "NO",
These Displays (Version-up, Public mode setting screen, Pass Word input screen of Public Mode,
the adjustment process mode, K mark of inspection mode) are enabled regardless of this setting.
: the content of the last memory is followed.
When setting to not Normal,
ON TIMER (Watching reservation) has priority.
When setting to "NORMAL", [INPUT MODE FIXED] is set to "VARIABLE". and [INPUT MODE FIXED] is prohib-
ited to select. (selection impossible.)
: If [INPUT MODE START] is set to Normal, input mode is not fixed.
: when "INPUT MODESTART" is active, it is impossible to switch to another channel or input
source.
: when "INPUT MODESTART" is active the unit starts at the input mode which is selected
when power is turned on in the case of the AC-ON only.
: when "INPUT MODESTART" is active the unit starts at the input mode which is selected
when power is turned on in any case (AC→ON, remote control→ON, main unit's key→ON)
If [INPUT MODE START] is Normal, this function cannot be set.
Set to "VARIABLE" automatically.
When setting to "FIXED",
The item related to the channel setting and input selection in Menu are not displayed.
ON TIMER (Watching reservation) is not active.
* These items does not exist according to the model.
3 – 13