FLCH4R Garage and
Utility Electric Heater
Installation, Operation & Maintenance Instructions
Model No.
Volts
208
FLCH4R
240
WHEN USING ELECTRIC APPLIANCES, BASIC PRECAUTIONS
SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS,
INCLUDING THE FOLLOWING:
1.
Read all instructions before installing or using this heater.
2.
This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials, such as
furniture, pillows, bedding papers, clothes, etc. and curtains
at least 3 feet (0.9 m) from the front of the heater.
3.
Extreme caution is necessary when any heater is used by
or near children or invalids and whenever the heater is left
operating and unattended.
4.
Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a
reputable electrician before using.
5.
Do not use outdoors.
6.
To disconnect heater, turn controls to off, and turn power to
heater circuit at main disconnect panel.
7.
Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock, fire
or damage to the heater.
8.
To prevent a possible fire, do not block air intake or exhaust
in any manner.
9.
A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint, or flammable liquids are
used or stored.
PPD 39413
Amps
High
Low
High
17.3
8.66
3600
20
10
4800

IMPORTANT INSTRUCTIONS

WARNING
SAVE THESE INSTRUCTIONS
Watts
BTU/HR
Low
High
1800
12284
2400
16378
!
10. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
11. This heater is provided with automatic resetting thermal limit
and an alarm beeper to alert user if heater has overheated.
If the alarm has activated, immediately turn off the heater
and inspect and remove any objects around heater that may
have blocked the airflow or otherwise caused the heater
to overheat. Do not continue to use heater if it repeatedly
overheats and activates the alarm.
CAUTION - On FFCH.R models, once heater has cycled off
on the thermal limit, the heater will not return to operation until
the user restarts and reprograms the control. Therefore, this
unit is not recommended for freeze protection applications.
12. This heater is intended for comfort heating applications and
not intended for use in special environments. Do not use
damp or wet locations such as marine or greenhouse or in
areas where corrosive or chemical agents are present.
13. When installing, see INSTALLATIONS INSTRUCTIONS for
additional warnings and precautions.
14. For safe and efficient operation, and to extend the life of
your heater, keep your heater clean - See MAINTENANCE
INSTRUCTIONS.
15. This heater is not to be used as a portable unit and or have a
cord and plug installed. (HARD WIRED ONLY)
Min Fuse
Phase
Size*
Low
6142
1
25
8189
1
25
5200-11227-000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLCH4R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fahrenheat FLCH4R

  • Page 1: Important Instructions

    FLCH4R Garage and Utility Electric Heater Installation, Operation & Maintenance Instructions Min Fuse Model No. Volts Amps Watts BTU/HR Phase Size* High High High 17.3 8.66 3600 1800 12284 6142 FLCH4R 4800 2400 16378 8189 IMPORTANT INSTRUCTIONS WARNING WHEN USING ELECTRIC APPLIANCES, BASIC PRECAUTIONS 10.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Unpacking Y our New Heater WARNING Remove heater from box, locate parts bag in packing material, and inspect to make sure heater is not damaged or missing parts. If To prevent a possible fire, injury to persons or damage to the heater, damaged or parts are missing, call our Technical Service Hotline at adhere to the following: 1-800-642-4328 for assistance.
  • Page 3 INSTALLATION INSTRUCTIONS Figure 4 Wall Mounting Figure 5 Ceiling Mounting 30° Tilt FOR WALL MOUNT APPLICATIONS FOR CEILING MOUNT APPLICATIONS DETAILED BRACKET ASSEMBLY ILLUSTRATION Figure 6 Minimum Clearances WARNING: Fall Hazard - Heater must be attached to a joist with 3 screws (two at keyhole slots and third safety screw at center hole) to prevent heater from possibly falling.
  • Page 4 WIRING - INSTRUCTIONS After heater has been properly mounted to the building structure and Heater is provided with a 7/8” (22mm) hole into wiring compartment for appropriate branch circuit wiring has been routed to the heater location in routing of branch circuit conductors. Appropriate conduit and fittings must be accordance with the National Electrical Code and local codes, the heater is provided for correct and safe installation.
  • Page 5 WIRING - INSTRUCTIONS Figure 12: Wiring Diagram for FLCH4R Figure 13: Field wiring connected to heater Figure 14: Wire connections carefully pushed wires using wire nuts into wiring compartment. Make the three connections as shown Carefully push the wires and connections...
  • Page 6 Automatic Fan Delay: The FLCH4R is provided with an automatic fan off delay. As the room ambient reaches the preset temperature level of the heater control...
  • Page 7 MAINTENANCE - INSTRUCTIONS User Cleaning Instructions: 1. After the heater has cooled, a vacuum cleaner with brush attachment may be used to remove dust and lint from exterior surfaces of the heater including the grille opening. Compressed air may also be used to blow out dust from inside heater. 2.
  • Page 8 LIMITED WARRANTY The products covered by this installation manual, manufactured and/or sold by Marley Engineered Products, are warranted against defects in workmanship and materials for one year from date of purchase. This warranty does not apply to damage from accident, misuse, or alteration;...