The Common Errors And Solutions Of The System; Fault Phenomenon : There Is No Display; Fault Phenomenon : Display Rupture; Fault Phenomenon : Display A Black Screen - OEM BYC07HE User Manual

Programming touch screen heating thermostat

Advertisement

The period-time mode
5+2:Monday to Friday is set as the same; Saturday to Sunday is set as the same.
PrG
6+1:Monday to Saturday is set as the same. Sunday is individually controlled.
7:Monday to Sunday is set as the same.
Antifreeze
LtP
Low temperature protection, what is suitable for the water system
temperature.
Sensor or temperature control mode
Sen
IN:internal control, room sensor
control, the internal room temperature sensor, external sensor overheating protecting
External temperature sensor limit
tOP
The sensor is set to ALL, the temperature limit external sensor value
Internal sensor hysteresis
dt0
Built-in temperature sensor hysteresis
External sensor hysteresis
dt1
External temperature sensor hysteresis
Backlighting status
bL
Backlight lighting mode, can be set according to personal preference
Status at re-power
Sat
Used to control the power state of the boot
Restore factory settings
deF

[ The common errors and solutions of the system ]

1. Fault phenomenon : There is no display

Reason & solution:
1、Power supply system is having problems or power is supplied incorrectly, please check if the inlet wire is normal.
2、If the connection is not right, please wired up as the wiring diagram on the back side.
3、Actual temperature is too low, please note the thermostat temperature range. If the temperature is lower than -5 ℃, the unit cannot
normally display.
4、Power supply box and the motherboard Coupling is not connected correctly, please connect correctly.
5、Power supply box and the motherboard Coupling are opposite inserted, please mind the direction
6、Power supply box and the motherboard Coupling is broken, please don't overexert. Coupling length is 6cm, the installation must be
careful. If damaged, no warranty and replacement

2. Fault phenomenon : Display rupture

Reason solution: Display encounters hard objects or sudden force, no replacement and warranty

3. Fault phenomenon : Display a black screen

Reason solution: If the display surface temperature is too high, please note whether there is heater nearby, if so please remove.
4. Fault phenomenon : Display ER0 or ER1
Reason solution:
ER0:If built-in sensor is abnormal, please pay attention to whether the small black dot in temperature sensing window was damaged during
removal
ER1:The system is set in the dual temperature control (ALL) mode, or it is not connected with an external sensor, or the external sensor is
abnormal.
5. Fault phenomenon : No pen on LCD
Reason solution: Please check whether the iron plate is deformation when installation. If it is deformation, please correct it.
6. Fault phenomenon : No backlight
Reason solution: Please check whether backlight lamp connection is broken when removing in the panel.
7. Fault phenomenon : Backlight always bright
Reason solution: 1、The ON is set in the system menu bL
8. Fault phenomenon : Large deviation of measurement temperature and the actual temperature
Reason solution: 1、The thermostat should be installed at ventilated place. It can not be installed at the place in direct sunshine or nearby the
heater
2、Back connection screw is not locked, causing terminal serious fever
9. Fault phenomenon : Display 0 degrees
Reason solution: It is normal if thermostat display 0 degrees when the actual environment is below 0 degrees.
[ Dimension in mm ]
5+2 / 6+1 / 7
On: Enable
/ OFF: Disable
IN: Built-in
OUT: External
ALL:Dual temperature control
Out:external control, floor sensor
40-80℃
0.5-4℃
0.5-5℃
On: Always on
OFF:Auto turn off after 5sec
OFF: off status at every time
On: the same as previous,
Restore factory settings
2、If it is damaged, please replace it.
BYC07
5+2
OFF
To prevent the pipe from freezing at low
IN
ALL:double temperature double
50℃
1℃
3℃
OFF
OFF
To restore the default settings
4