Download Print this page

Philips HR7735 Service Manual page 6

Hide thumbs Also See for HR7735:

Advertisement

REPAIR INSTRUCTION
To remove the Housing:
1. Remove the Toolholder coupling by turning it
counterclockwise with protected tongs to prevent the
coupling from damages (You can use e.g. foam rubber).
2. Remove the 4 screws on the bottomside of the
foodprocessor.
The green arrow shows you the hole, where you can stick
through a pin to fi xate the acc. drive wheel, when you want
to remove the blender coupling. After that you can turn
the blender coupling clockwise ´for removing it.
3. Remove the 2 last screws (marked with the red arrows).
After this you can remove the housing.
- In this situation, you could replace for example the cord set
or the PCB.
- Be sure, that you don´t loose the Spring – Bowl detection
on the bottomside of the housing!
- Be sure, that a replaced cord set is also placed in the
designed cable guide.
HR7735/55
6-8

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Hr7755