Robertshaw 8425 User Manual page 7

Non-programmable
Hide thumbs Also See for 8425:
Table of Contents

Advertisement

110-1090.qxd
7/22/04
TERMINAL LEGEND - 8425
TERM
EQUIPMENT TO CONNECT
R
24 VAC hot connection
C
24 VAC common connection
L
System fault indicator
connection
W1
Second stage connection
for non heat-pump applications
Y2
Second stage cooling
connection
Y1
First stage compressor
connection
W2/E Second stage heat or
Emergency heat connection
B
Heat active reversing
valve connection
O
Cool active reversing
valve connection
G
Indoor fan connection
*
Do not connect W1 in heat pump applications. Connect auxiliary heat to W2/E.
** Most heat pump systems will have a cool active or a heat active reversing valve. Use the
appropriate terminal.
C
Y2
R
W2/E
NON_HP HP
L
G
O
B
Y1 W1
ELEC GAS
ELECTRIC/GAS SWITCH
Selects fan control.
15. Set the Electric/Gas switch to either GAS for a gas/oil heating
system or ELEC for an electric heating system (Figure 5).
16. Set the HP option switch to either the HP for heat pump or
NON_HP for furnace applications (Figure 5).
17. Replace thermostat cover by snapping into place.
8:39 AM
Page 7
REQ?
TERMINAL FUNCTION
Yes
For input of 24VAC hot
side of transformer
Yes
For input of 24VAC
common side of
transformer
No
For connection of system
fault indicator (if present)
No*
Energizes on a call
for heat
No
Energizes on a call for
second stage cooling
Yes
Energizes on a call for
first stage of heating
and cooling
Yes*
Energizes on a call for
second stage or
emergency heat
Yes** Energizes when in the
HEAT or EM modes
Yes** Energizes when in the
COOL mode
Yes
Energizes with E & Y1, Y2
and W2 terminals or with
FAN option switched to
the ON position
°
F
HP OPTION SWITCH
Heat pump switch.
Figure 5
7