Table of Contents

Advertisement

QQ
3 7 63 1515 0
(5) Example of Display.
•SET UP in progress
8 digits display LCD
TNo.
Min
Sec
11
11
11
•Operation (PLAY, SEARCH, etc.) in progress perfectly
identical with that in the normal mode.
- Error Number Indication
If the CD should fail to operate or if an error has taken place during operation the player will enter into the error
mode, and the cause of the error will be numerically indicated.
This is aimed at assisting in analysis or repair.
(1) Basic Means of Display
• Examples of Display
(2) Error Codes
Error
Classification
Code
10
ELECTRIC
TE
L 13942296513
11
ELECTRIC
12
ELECTRIC
14
ELECTRIC
17
ELECTRIC
19
ELECTRIC
30
ELECTRIC
A0
SYSTEM
A1
SYSTEM
50
MECHANISM
www
60
MECHANISM
70
MECHANISM
80
MECHANISM
.
* Setup means a series of operations after focusing up to sound output.
http://www.xiaoyu163.com
ERROR-xx
Description
Carriage home failure
Focus failure
SETUP failure
Subcode failure
Mirror failure
Set up failure
Set up failure
Search time out
Power failure
Mechanism power
failure
An error upon ejection
An error while putting in
and out the tray
x
ao
u163
y
An error upon elevation
i
An error with an empty
magazine inserted
http://www.xiaoyu163.com
2 9
8
•Protection/Error upon occurrence(8 digits display LCD)
(a) Error number indicated
ERROR–xx
(b) Track number and
absolute time indicated
TNo.
Min
10
40
Cause/Detail
Carriage doesn't move to or from the innermost position
Q Q
→Home switch failed and/or carriage immobile
3
6 7
1 3
1 5
Focus failed
→Defects, disc upside-down, severe vibration
Spindle failed to lock or subcode unreadable
→Spindle defective, defect, severe vibration
Unrecorded CD-R
The disc is upside-down, defects, vibration
AGC protect failed
→Defects, disc upside-down, severe vibration
Tracking error waveform is too unbalanced (>50%) or
level is too small
→The pickup unit or tracking error circuitry is N.G.
Failed to reach target address
→Carriage/tracking defective and/or defects
Power overvoltage or short circuit detected
→Switching transistor defective and/or power abnormal
Mechanism elevation reference voltage is out of
prescription
→EREF adjustment VR and/or power abnormal
MAG switch release time has time out
Elevation time out when eject
Tray in / out time has time out
Tray is caught when put in
co
Elevation time has time out
No disc is available
.
KEH-P690,P6950
9 4
2 8
Select the display with the
BAND key.
Sec
05
0 5
8
2 9
9 4
2 8
m
9 9
9 9
39