Con Nec Tion Of Rpm-Indicator With Gen Er A Tor-Pickup; Oil Pres Sure And Oil Tem Per A Ture - LIMBACH L 2000 Series Installation Manual

Table of Contents

Advertisement

Flugmotoren
5.3.3.3
Con nec tion of RPM-Indicator with
Gen er a tor-pickup
Al ter na tively an RPM-indicator with Gen er a tor-pickup
may be used (Fig.: 5-6). Check wether the Gen er a tor has
the ap pro pri ate con nec tor "W" (Fig.:5-8).
The pickup "W" on the gen er a tor is con nected with the
ap pro pri ate ter mi nal on the RPM in di ca tor (Fig.:5-7).
Note the dif fer ent con nec tors for the dif fer ent sup ply
volt ages.
Af ter in stal la tion, the in stru ment must be cal i brated.
Mea sure the pro pel ler rpm with an op ti cal ta chom e ter at
ap prox i mately 2/3 max en gine rpm and ad just the screw
"S".
5.3.3.4

Oil pres sure and oil tem per a ture

(250.215.010.000)
Pin
Des ti na tion
1
+12 V
2
+12 V (Light)
3
(GND)
4
Sensor, temperature, VDO
5
(GND)
6
Sensor, pressure 0-10 bar,
VDO
7
GND
D+ B+
Fig.: 5-9 Internal Diagram of Generator with RPM-pickup "W"
Prepared by: J. B. Meyer
Checked by:
Installation Manual
L 1700, L2000 and L 2400 Series
DF D-
W
Replaces edition from: 10.03.86
Edition: 01.03.1999
20
15
25
10
5
0
x100
rpm
Fig.: 5-6 RPM Indicator "W"
S
+
W
24
Fig.: 5-7 RPM Indicator "W" Connector
Side
W
Fig.:5-8 Generator with RPM-pickup "W"
Page: 5-7
Reg. Number:
5
30
35
40
L
-
W
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L 1700 seriesL 2400 series