Nikon SF-200 Product Manual page 12

Slide feeder for 4000 ed (super coolscan 4000 ed) and ls-2000 (super coolscan 2000) nikon film scanners

Advertisement

Open the SF-200 (S)'s magazine cover, pull back the feed push-plate to the end of its grove, and hook
it in the notch so that it does not spring back to its original position.
Click the double right-arrow button in the attachment utility to move the feed mechanism to where it
is fully visible. If you move the feed mechanism too far, click the left-arrow button to move it back. The
single-arrow buttons can be used for fine adjustments. Once the feed mechanism is visible, insert the
pegs on the attachment into the holes in the feed mechanism.
Feed-mechanism
attachment
Click the OK button in the attachment utility window to return the feed mechanism to its initial
position. You are now ready to begin scanning.
4.4 Removing attachment
When scanning slides with flat mounts or slides less than 2 mm thick, you will need to remove the
attachment. Use the attachment utility as described above to move the feed mechanism into the
magazine, then remove the attachment and click OK to return the feed mechanism to its initial posi-
tion.
Caution
Be sure that the attachment is securely in place. If the attachment is loose, slides may not feed properly
and damage to the SF-200 (S) could result.