Level 3 Repair
8-3-15. LCD
LCD is still off after PWR ON
Yes
No
Check the connection of
Reconnect the HDC 702
HDC 702
Yes
No
Check VCC_3.3V_LCD =
Resolder or Replace the PMIC(U500)
3.3V(C549)
Yes
No
Check VCC_2.2V_LCD =
Resolder or Replace the U707
2.2V(C735)
Yes
No
Check ELVDD_4.6V =
Resoldering L703, L706
4.6V(C713), ELVSS_-4.9V =
Resoldering U706
3.0~4.4V(C712)
Yes
Replace LCD
Module
Yes
END
8-51
Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsung's written authorization is strictly prohibited.