Professional Entertainment Technology BEAM-2R/PRO User Manual

Professional beam moving head

Advertisement

Quick Links

BEAM-2R/PRO
Professional
Beam Moving Head

User Manual

Professional Entertainment Technology
Please read these instructions carefully before use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BEAM-2R/PRO and is the answer not in the manual?

Questions and answers

Summary of Contents for Professional Entertainment Technology BEAM-2R/PRO

  • Page 1: User Manual

    BEAM-2R/PRO Professional Beam Moving Head User Manual Professional Entertainment Technology Please read these instructions carefully before use...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS  1.   Safety Instructions .....................2  2.   Technical Specifications....................4  3. Description .......................5  3.1 Control Panel ....................5  4. Gobo and Lamp ......................6  4.1 Gobo .........................6  4.2 Lamp.........................7  4.3 Change the Lamp....................7  5. How To Set The Unit ....................9  5.1 Main Function ....................9  5.2 Home Position Adjustment................19  5.3 Error Information....................21  6. Control By Universal DMX Controller ..............22  6.1 Connection .....................22  6.2 Channel Mode Setting ..................23  6.3 Address Setting....................23  6.4 DMX 512 Configuration ..................24  7. Troubleshooting......................27 8. Maintenance and Cleaning..................29 ...
  • Page 4: Safety Instructions

    1. Safety Instructions Please read carefully the instruction manual, which includes important  information about the installation, usage and maintenance.  WARNING    Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that  they also receive this instruction manual.  Important:  Damages  caused  by  the  disregard  of  this  user  manual  are  not  subject  to  warranty.  The  dealer will not accept liability for any resulting defects or problems.  Unpack and check carefully that there is no transportation damage before using the unit.  The unit is for indoor use only. Use only in a dry location.  Do install and operate by qualified operator.  Do not allow children to operate the fixture.  Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only.  The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent  surfaces.    Be sure that no ventilation slots are blocked; otherwise the unit will be overheated.  Before operating, ensure that the voltage and frequency of power supply matches the power  requirements of the unit.  It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.  Maximum ambient temperature TA: 40℃. Don’t operate it when the temperature is higher.  Don’t connect the device to any dimmer pack.  During initial start‐up some smoke or smell may arise. This is a normal process and does not  necessarily mean that the device is defective, and it will decrease gradually within 15 minutes. ...
  • Page 5 Do not operate in dirty or dusty environment; do clean the fixture regularly.  Do not touch any wire during operation as there might be a hazard of electric shock.  Avoid power wires twist other cables.  The minimum distance between light output and the illuminated surface must be more than  12 meters.  Disconnect mains power before fuse/lamp replacement or servicing.  Replace fuse/lamp only with the same type.  In the event of serious operating problem, stop using the unit immediately.    Never turn on and off the unit time after time.  The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.  Do not open the unit as there are no user serviceable parts inside.  Never  try  to  repair  the  unit  by  yourself.  Repairs  carried  out  by  unskilled  people  can  lead  to  damage  or  malfunction.  Please  contact  the  nearest  authorized  technical  assistance  center  if  needed. ...
  • Page 6: Technical Specifications

    2. Technical Specifications DMX Channels: 14&16 channels  Smooth 0~100% dimming and variable strobe speeds  Motorized focus by DMX control  Automatic Pan/Tilt position correction  Excellent ventilation, ensuring reliable operation  Voltage: AC 100~240V, 50/60Hz  Power Consumption: 250W  Lamp: PHILIPS MSD Platinum 2R, about 6000hrs  Beam Angle: 3°  Dimension: 311 x 256 x 476mm  Weight: 15Kgs ...
  • Page 7: Description

    3. Description 3.1 Control Panel    1. Display: Show the various menus and the selected functions;  2. LED: POWER  On    Power On  DMX  On    DMX input present  3. Button: MENU  To enter into, move backward or leave the menu  Move up in the menu  Move down in the menu  ENTER  Enter the desired functions  4. DMX IN: For DMX 512 operation, use 3/5‐pin XLR plug cable to link the units together;  5. DMX OUT: For DMX 512 operation, use 3/5‐pin XLR plug cable to link the units together  6. POWER IN: For connection to a socket (100~240V, 50/60Hz) via the supplied mains cable. ...
  • Page 8: Gobo And Lamp

    7. POWER OUT: Connect to supply power to the next unit. 8. Fuse (T 6.3 A): Protect the unit from damage of over current.  4. Gobo and Lamp 4.1 Gobo    DANGER!  Install/change the gobo‐wheel with the device switched off only. ...
  • Page 9: Lamp

    4.2 Lamp    Philips MSD Platinum 2R    Because  of  its  high  internal  pressure,  there  might  be  a  risk  that  the  Discharge  lamp  would explode during operation. The lamp emits intense UV radiation which is harmful  to  the  eyes  and  skin.  The  high  luminance  of  the  arc  can  cause  severe  damage  to  the  retina if you take a close look at the lamp.  To protect the lamp, always turn off the lamp first (via control panel or DMX controller)  and let the unit run at least five minutes to cool down before switching off the mains  supply. Never handle the lamp or luminary when it is hot. ...
  • Page 10 Fig.2  Use  1/4  Turn  loosen  the  screws and take out the fan.  Fig.3 Take away the old lamp.  Fig.4 Unplug all the connect wires over the lamp and wear anti‐static gloves to take on the  lamp. And then change a new lamp. ...
  • Page 11: How To Set The Unit

    5. How To Set The Unit   5.1 Main Function      Turn  on  the  unit,  press  MENU  button  into  menu  mode,  press  UP  and  DOWN  button  until  the  required  function  is  shown  on  the  monitor.  Select  the  function  by  ENTER  button.  Use  UP  and  DOWN button to choose the submenu, press the ENTER button to store and automatically return  to the last menu. Press MENU button or let the unit idle one minute to exit menu mode. ...
  • Page 13 DMX Functions  Enter menu mode, select DMX Functions, press ENTER button to confirm, use UP and DOWN  button to select DMX Address, DMX Channel Mode or View DMX Value    DMX Address ‐ DMX512 address setting  Select  DMX  Address,  press  ENTER  button  to  confirm,  the  present  address  will  blink  on  the  display, use UP and DOWN button to adjust the address from 1 to 512, press ENTER button to  store. Press MENU button back to the last menu or let the unit idle one minute to exit menu  mode.  DMX Channel Mode ‐ channel mode  Select DMX Channel Mode, press ENTER button to confirm, present channel mode will blink  on the display, use UP and DOWN button to select Mode 1 (16) or Mode 2 (14), press ENTER  button to store. Press MENU button back to the last menu or let the unit idle one minute to  exit menu mode. ...
  • Page 14 View DMX Value  Select  View  DMX  Value,  press  ENTER  button  to  confirm.  Channel  function  and  its  value  will  show on the display, use UP and DOWN button to view other DMX value. Press MENU button  back to the last menu or let the unit idle one minute to exit menu mode.  Fixture Setting  Enter menu mode, select Fixture Setting, press ENTER button to confirm, use UP and DOWN  button  to  select  Pan  Inverse,  Tile  Inverse,  P/T  Feedback,  BL.O.  P/T  Moving,  BL.O.  Color  Change or BL.O. Gobo Change.  Pan Inverse  Select Pan Inverse, press ENTER button to confirm, present mode will blink on the display, use  UP and DOWN button to select No (normal) or Yes (pan inverse), press ENTER button to store.  Press MENU button back to the last menu or let the unit idle one minute to exit menu mode.  Tilt Inverse  Select Tilt Inverse, press ENTER button to confirm, present mode will blink on the display, use ...
  • Page 15 BL.O. Color Change ‐ Blackout while change color  Select  BL.O.  Color  Change,  press  ENTER  button  to  confirm,  present  mode  will  blink  on  the  display, use UP and DOWN button to select No (normal while change color) or Yes (blackout  while change color), press ENTER button to store. Press MENU button back to the last menu or  let the unit idle one minute to exit menu mode.  BL.O. Gobo Change ‐ Blackout while change gobo  Select  BL.O.  Gobo  Change,  press  ENTER  button  to  confirm,  present  mode  will  blink  on  the  display, use UP and DOWN button to select No (normal while changing gobo) or Yes (blackout  while changing gobo), press ENTER button to store. Press MENU button back to the last menu  or let the unit idle one minute to exit menu mode.  Lamp Setting  Enter menu mode, select Fixture Setting, press ENTER button to confirm, use UP and DOWN  button ...
  • Page 16 (When you operate the unit via DMX controller, set the value of channel “special function” to  “lamp off”, waiting for 5 seconds, then the lamp will be off if you choose “yes” mode).  On If DMX On ‐ Lamp turns on when DMX signal is detected  Select On If DMX On, press ENTER button to confirm, present mode will blink on the display,  use UP and DOWN button to select Yes (Lamp turns on when DMX signal is detected) or No  (keep  the  present  state),  press  ENTER  button  to  store.  Press  MENU  button  back  to  the  last  menu or let the unit idle one minute to exit menu mode (If the lamp is off via DMX signal, you  can reconnect the DMX controller to make the lamp on).  Off If DMX Off ‐ Lamp turns off when DMX signal is cut off  Select Off If DMX Off, press ENTER button to confirm, present mode will blink on the display,  use  UP  and  DOWN  button  to  select  Yes  (Lamp  turns  off  when  DMX  signal  is  cut  off),  press  ENTER ...
  • Page 17 Display Inverse  Select Display Inverse, press ENTER button to confirm, present mode will blink on the display,  use UP and DOWN button to select No (normal display) or Yes (inverse display), press ENTER  button to store. Press MENU button back to the last menu or let the unit idle one minute to  exit menu mode.  Backlight Auto Off  Select  Backlight  Auto  Off,  press  ENTER  button  to  confirm,  present  mode  will  blink  on  the  display, use UP and DOWN button to select No (display always on) or Yes (display goes off one  minute  after  exiting  menu  mode),  press  ENTER  button  to  store.  Press  MENU  button  back  to  the last menu or let the unit idle one minute to exit menu mode.  Backlight Intensity  Select  Backlight  Intensity,  press  ENTER  button  to  confirm,  present  mode  will  blink  on  the  display, ...
  • Page 18 Press MENU button back to the last menu or let the unit idle one minute to exit menu mode.  Language  Select Language, press ENTER button to confirm, present mode will blink on the display, use  UP and DOWN button to select English or Chinese, press ENTER button to store. Press MENU  button back to the last menu or let the unit idle one minute to exit menu mode.  Fixture Test  Enter  menu  mode,  select  Fixture  Test,  press  ENTER  button  to  confirm,  use  UP  and  DOWN  button to select Auto Test or Manual Test  Auto Test  Select  Auto  Test,  press  ENTER  button  to  confirm,  the  unit  will  run  built‐in  programs  to  automatically test pan, tilt, color, gobo, gobo rotation, shutter, dimmer, prism, prism rotation,  focus, and lamp on/off. . Press MENU button back to the last menu or exit menu mode after  auto test. ...
  • Page 19 Lamp On time  Select Lamp On time, press ENTER button to confirm, lamp on time will show on the display,  press ENTER button to confirm, use UP and DOWN button to select Exit or Reset Time, press  ENTER button to confirm. Press MENU button back to the last menu or exit menu mode let the  unit idle one minute.    Firmware Version  Select Firmware Version, press ENTER button to confirm, firmware version will show on the  display, press MENU button back to exit.  Reset Functions  Enter menu mode, select Reset Function, press ENTER button to confirm, use UP and DOWN  button to select Pan/Tilt, Shutter/Prism, Color, Gobo, Focus or All.  Pan/Tilt ‐ Reset Pan/Tilt  Select Pan/Tilt, press ENTER button to confirm, use UP and DOWN button to select Yes (the  unit will run built‐in program to reset pan and tilt to their home positions) or No, press ENTER  button to store. Press MENU button back to the last menu or let the unit idle one minute to  exit menu mode.  Shutter/Prism ‐ Reset Shutter/ Prism  Select Shutter/Prism, press ENTER button to confirm, use UP and DOWN button to select Yes  (the unit will run built‐in program to reset shutter and prism to their home positions) or No,  press ENTER button to store. Press MENU button to exit.    Color ‐ Reset Color  Select Color, press ENTER button to confirm, use UP and DOWN button to select Yes (the unit  will run built‐in program to reset color to their home positions) or No, press ENTER button to  store. Press MENU button to exit.    Gobo ‐ Reset Gobo  Select Gobo, press ENTER button to confirm, use UP and DOWN button to select Yes (the unit  will  run  built‐in  program  to  reset  GOBO  wheel  to  their  home  positions)  or  No,  press  ENTER ...
  • Page 20 button to store. Press MENU button to exit.    Focus ‐ Reset Focus  Select Focus, press ENTER button to confirm, use UP and DOWN button to select Yes (the  unit will run built‐in program to reset Focus to their home positions) or No, and press ENTER  button to store. Press MENU button to exit  All ‐ Reset All  Select All, press ENTER button to confirm, use UP and DOWN button to select Yes (the unit will  run built‐in program to reset all motors to their home positions) or No, press ENTER button to  store. Press MENU button to exit.  Special Functions  Enter  menu  mode,  select  Special  Functions,  press  ENTER  button  to  confirm,  select  Fixture  Maintenance or Factory Setting.  Fixture Maintenance  Select  Fixture  Maintenance,  press  ENTER  button  to  confirm,  use  UP  and  DOWN  button  to  select Interval or Remain Time. ...
  • Page 21: Home Position Adjustment

    5.2 Home Position Adjustment    Press  MENU  button  into  menu  mode,  then  press  ENTER  button  for  about  3  seconds  into  offset  mode  to  adjust  the  home  position.  Select  the  function  by  ENTER  button.  Use  UP  and  DOWN  button to choose the submenu, press the ENTER button to store and automatically return to the  last menu. Press MENU button to exit.    PAN - pan home position adjustment  Enter offset mode, Select PAN, press ENTER button to confirm, the present position will blink on  the display, use UP and DOWN button to offset the value from ‐128 to 127, press ENTER button to  store. Press MENU button to exit. ...
  • Page 22 COLOR - Color home position adjustment  Enter offset mode, Select COLOR, press ENTER button to confirm, the present position will blink on  the display, use UP and DOWN button to offset the value from ‐128 to 127, press ENTER button to  store. Press MENU button to exit.  GOBO - Gobo home position adjustment  Enter offset mode, Select GOBO, press ENTER button to confirm, the present position will blink on  the display, use UP and DOWN button to offset the value from ‐128 to 127, press ENTER button to  store. Press MENU button to exit.  PRISM 1 - Prism 1 rotation home position adjustment  Enter offset mode, Select PRISM 1, press ENTER button to confirm, the present position will blink  on the display, use UP and DOWN button to offset the value from ‐128 to 127, press ENTER button  to store. Press MENU button to exit.  PRISM 2 - Prism 2 home position adjustment  Enter offset mode, Select PRISM 2, press ENTER button to confirm, the present position will blink  on the display, use UP and DOWN button to offset the value from 0 to 255, press ENTER button to  store. Press MENU button to exit.  R‐PRISM - Prism1 rotation home position adjustment  Enter offset mode, Select R‐PRISM, press ENTER button to confirm, the present position will blink  on the display, use UP and DOWN button to offset the value from ‐128 to 127, press ENTER button  to store. Press MENU button to exit.  FOCUS - Focus home position adjustment  Enter offset mode, Select FOCUS, press ENTER button to confirm, the present position will blink on  the  display,  use  UP  and  DOWN  button  to  offset  the  value  from  0  to  255,  press  ENTER  button  to  store. Press MENU button to exit. ...
  • Page 23: Error Information

    5.3 Error Information    Lamp Startup Fail  It appears when there is no lamp or some wires are damaged.  Temperature Sense Error  It appears when temperature check board is damaged.  Lamp Too Hot Power Off  It appears when temperature is detected higher than 110℃. Check if the unit is properly ventilated,  or fans or temperature check board may is damaged.  Lamp Too Hot Low Power  It appears when temperature is detected higher than 105℃, the unit will run on a low power level.  Maintenance Fixture  It appears when the maintenance remaining time becomes 0S, please enter menu mode and reset  the time.  Lamp On Over 700 Hour  It appears when the lamp has been on over 700 hours, please turn off the lamp.  Memory Initial Fail  It appears when the memory IC is damaged.  CPU‐B Error, CPU‐C Error, CPU‐D Error  They appear when board P.C or some wires are damaged.  Pan Reset Error, Pan Encode Error, Tilt Reset Error, Tilt Encode Error, Shutter Reset Fail, Dimmer  Reset Fail, Color Reset Fail, Gobo Reset Fail, Focus Reset fail.  They  may  appear  when  turning  on  or  resetting  the  unit,  for  some  parts  such  as  board  P.C  are  damaged. Please contact the qualified maintenance. ...
  • Page 24: Control By Universal Dmx Controller

    6. Control By Universal DMX Controller 6.1 Connection    1. At  last  unit,  the  DMX  cable  has  to  be  terminated  with  a  terminator.  Solder  a  120‐ohm  1/4W resistor  between  pin  2(DMX‐)  and  pin  3(DMX+)  into  a  3‐pin  XLR‐plug  and  plug  it  in  the DMX‐output of the last unit. 2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the input of the next unit. The cable cannot be branched or split to a “Y” cable. DMX 512 is a very high‐speed ...
  • Page 25: Channel Mode Setting

    6. 3 pin XLR connectors are more popular than 5 pins XLR. 3 pin XLR: Pin 1: GND, Pin 2: Negative signal (‐), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (‐), Pin 3: Positive signal (+), Pin4, Pin5 not used. 6.2 Channel Mode Setting    Enter  menu  mode,  select  DMX  Functions,  press  ENTER  button  to  confirm,  use  UP  and  DOWN  button to select DMX Channel Mode, press ENTER button to confirm, present channel mode will  blink  on  the  display,  use  UP  and  DOWN  button  to  select  Mode  1  (16)  or  Mode  2  (14)  channel  Mode, press ENTER button to store. Press MENU button back to the last menu or let the unit idle ...
  • Page 26: Dmx 512 Configuration

      6.4 DMX 512 Configuration    16 Channels Mode: ...
  • Page 28 14 Channels Mode: ...
  • Page 29: Troubleshooting

    7. Troubleshooting Following  are  a  few  common  problems  that  may  occur  during  operation.  Here  are  some  suggestions for easy troubleshooting:  A. The unit does not work, no light and the fan does not work 1. Check the connect power and main fuse. 2. Measure the mains voltage on the main connector. 3. Check the power on LED to see if it can be light up or not. B. Not responding to DMX controller 1. DMX  LED  should  be  on.  If  not,  check  DMX  connectors,  cables  to  see  if  they  are  linked properly.
  • Page 30 4. Try to use another DMX controller. 5. Check to see if the DMX cables run near or run alongside high voltage cables that may cause damage or interference to DMX interface circuit. C. One of the channels is not working well 1. The stepper motor might be damaged or the cable connected to the PCB is broken. 2. The motor’s drive IC on the PCB might be out of condition. D. The lamp is cutting out intermittently 1. The lamp is not working well. Check the mains voltage either too high or too low. 2. Internal temperature may be too high. Check if replacement of fan is needed on the head. E. If The pan belt is broken 1. Turn off the mains power. 2. Loosen the screws (A),open the cover (B). 3. Loosen the screws (C). 4. Unplug all the connect wires over the belt. 5. Change a new belt (D), put the belt around the axis gear and motor gear. 6. Plug all the connect wires back upon the belt. 7. Tighten all the screws. F. If The tilt belt is broken 1. Turn off the mains power. 2. Loosen  all  the  screws  (A)  and  open  the  right  arm  cover (B).
  • Page 31: Maintenance And Cleaning

    8. Maintenance and Cleaning Maintenance:  Ballast A. As the pictures shown above, please replace the cable or cable joints immediately once they’ve turned yellow. B. Do  maintain  the  fixtures  every  two  months  and  make  sure  that  all  the  screws  and  terminals have been locked firmly to make sure the normal performance of the fixtures.    Negligence of maintenance would cause malfunction of the fixture. Cleaning:  The  cleaning  of  internal  and  external  optical  lenses  and/or  mirrors  must  be  carried  out  periodically to optimize light output. Cleaning frequency depends on the environment in which the ...
  • Page 32 MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany www.monacor.com 01.03.12.2015...

Table of Contents