LHD6000
INSTALLATION
MANUAL
Manufacturer: Shenzhen Longhorn Technology Co., Ltd.
Add: Longhorn Hi-Tech Estate, TongFuyu Industrial Avenue,
Longhua, Shenzhen G. D. China
Post number: 518109
Tel: 800 830 8196
Fax: +86-755-28140429
Web address: http://www.long-horn.com
E-mail: service@long-horn.com

Advertisement

Table of Contents
loading

Summary of Contents for LONGHORN LHD6000

  • Page 1 LHD6000 INSTALLATION MANUAL Manufacturer: Shenzhen Longhorn Technology Co., Ltd. Add: Longhorn Hi-Tech Estate, TongFuyu Industrial Avenue, Longhua, Shenzhen G. D. China Post number: 518109 Tel: 800 830 8196 Fax: +86-755-28140429 Web address: http://www.long-horn.com E-mail: service@long-horn.com...
  • Page 2 INSTALLATION MANUAL...
  • Page 3: Installation Information

    16.Table of zone types descriptions Thank you for using LHD6000 alarm system of Longhorn. Please read the Installation Wire zones of the control panel Manual carefully before installing and using the alarm system in order to acquaint you with Zone number...
  • Page 4: Technical Parameters

    Types of fault Potential reasons Solutions Cancel this zone ,check the code Different detectors use the same learn again, make sure the detector code learn code learn has not been used Confirm carrier frequency of the The different carrier frequency of the Code learn unsuccessful detector detector and the control panel...
  • Page 5: Table Of Contents

    CONTENTS 3. Alarm warning devices such as bells may not alert people if they are installed in an improper position. If the alarm bell is installed outside, there are less likely to waken or alert people inside the bedrooms. System installation figure...................... 1 4.
  • Page 6 11.4 Phone field monitor......................20 12. Answering alarm communication code 11.5 Hearing current alarm type....................20 Communication between control panel and alarm center have two formats ADEMCO 4+1 and ADEMCO Contact 11.6 Hang-up/stop alarm dialing....................20 ID.The event code identifications as followed: 12.
  • Page 7: System Installation Figure

    If password is wrong, user can input password and operate again without inputting '#' in advance. The control panel will hang up if password is input incorrectly three times or user does not press any key in 30 seconds during the operations.
  • Page 8: General

    1. General 9.3.33 Zone type initialization Enter: 950 This is a new kind of intelligent security product. It transmits alarm information to the user via telephone network → → → → Operations: (PROG user password and is remotely controlled to deal with emergencies in time, ensuring user's personal and property safety. This product has complete functions, flexible configuration, strong destroy protection and convenient operations, being suitable for residences, stores, factories, 9.3.34 System defaults restoring...
  • Page 9: Notice Before Using

    9.3.26 User address recording Enter: 700 Entry delay: A period for user to enter detection area, activate the delay zone and disarm before the system alarms. During the period,user can activate several specified zones (entry zone etc) without → → →...
  • Page 10: Keypad Installation

    ● Standby power is offered overload protection by fast-blow fuse BATTERY(1A). If the fuse Functions: Add or reduce wireless detectors as required. opens, remove the short or overload condition, and then replace the fuse before restoring 12V 7.0Ah → → →...
  • Page 11 ● Connection between the wiring board of keypad and the control panel: Connect V_KEY, B,A and GND port in the Press(PROG→user password→#)→36→1→0800→#→36→2→2200→# control panel to those in the keypad wiring board respectively, and fix them by screws. Note: Before performing the functions above , please set 'Timed auto-arm/auto-disarm selection' first, refer to ●...
  • Page 12: Bell Output Terminal

    5.5.3 Keypad address XX=10(100 seconds) Different addresses need to be set when connecting one more keypads to avoid address clash. It can be reached XX=20( 200 seconds) by adjusting address dial-up switch on keypad back. See the table below: XX=30(300 seconds) The factory setting is XX=04(40 seconds) 1(NO1 keypad) Function: The system entry delay time adjustment.
  • Page 13: Telescopic Antenna Installation

    ● When telephone line is lost in self- checking status, the control panel will alarm for telephone line lost. "Loss" Functions: The control panel supports 4+1ADMECO and Contact ID communication. indicator will be on, and buzzer chirps twice in every two minutes until chirps 15 times(30minutes). When telephone line is restored, "Loss"...
  • Page 14: Alarm Mode

    7. Alarm mode 9.3.4 Operation password modification Enter:22 XXXX Alarm modes → → → → → Operations: (PROG user password XXXX protection Alarm types Voice Alarm Keypad Dial to Parameter definition: XXXX is 4 digits operation password. The factory setting is 1234. Bell zones alarm...
  • Page 15: Zone Number

    8.2 Definitions of zone number 9.3.1 Alarm telephone number Setting/canceling Input: 11 XY...Y The master controller: Wire zone: 01~16(9~16 zones is extended wire zones) (1) Set alarm phone number Wireless zone: 21~28 → → → → → Operations: (PROG user password XY...Y Help: 17 →...
  • Page 16: Parameters Setting

    9.2.2 Arm-stay Keypad Factory Setting items If the system is in 'DISARM' status, press 'STAY' key and enters arm-stay status; if the system is in 'AWAY' status, Numerical value/selection operations fault setting press 'STAY' key , input user password or operation password and press '#' key confirm then enter arm-stay status. Then the indicator flashes.