Contents Introduction ................ii About this Manual ............... ii Abbreviations ............... 1 System Overview ..............2 Operating - How to use the SSAS ........3 Normal mode ................3 Alert mode ..................3 Test mode ..................4 Iridium Tracking System ..............5 Connecting a PC ................
System Overview Alert Iridium Satellite System Button Box Iridium SSAS Box E-mail, SMS Test Button Box Iridium System Iridium Gateway 39285 In case a ship is being attacked by pirates or terrorists the crew The system has full global radio coverage. Covers A1, A2, A3 and A4 needs a possibility to send a silent alert message to a predefined areas.
SIM card will be deleted in order to make room for receiving an alert Operating - reset SMS. How to use the SSAS Notice: It is possible to send alert messages and make a voice call at the same time but a data call will be interrupted when an alert is activated. Normal mode The contents of the message are shown in table 1.
Deactivating the alert Test mode The alert can be deactivated in two ways. The test mode is used to check that the system is working properly. Either by pressing the test button or by sending an SMS message to the system. The test message will contain the same information as the alert message (table 1).
Iridium Tracking System Connecting a PC With the Iridium Tracking System the SSAS control unit can send When the Iridium SSAS Box is in normal mode the data interface of information about the ships position. There are two ways to get the the Iridium transceiver can be used for various data applications, e.g.
Installation Technical Specification Input voltage: 10 – 32 VDC Current consumption: Max. 300 mA Operating temperature: -15 to +55 degree Celcius Interfaces: PC data port: RS232, 19200 baud Iridium data port: RS232 GPS input: NMEA 0183 version 2.20 and 2.30 Following NMEA messages are supported: GPRMC, GPGLL, GPVTG and GPZDA Check sum is recommended...
Page 9
Dimensions and drilling plan Mounting Iridium SSAS Box * 50 * 50 * Free space for mounting, ** Free space for cable entry. 258.5 39286 DRILLING PLAN Iridium SSAS Alert Button Box / SSAS Test Button Box 4 pcs. ø6 Cable entry DRILLING PLAN 3 pcs.
The Iridium SSAS Box default IP parameters: Connection Scheme for push Terminals IP address: 192.168.2.40 Subnetmask: 255.255.255.0 Default gateway: 0.0.0.0 The IP address can be changed to fit any other local network. When 10 -32V DC DC + changing the IP address you must make sure to write down the new BAT + POWER DC -...
Page 14
there are several TCP/IP protocol installed. You can ignore the ones Now the Index page of the Iridium SSAS Box is shown. that have “Dial-Up” in the name associated with an internet service provider. In this example, the TCP/IP protocol associated with the If not then check the Internet settings and disable proxy server if this 3Com LAN network card has been selected.
Configuration parameters Range Default value Description Parameter Message configuration Email address lenght: 25 chars Max limit for Email length can be set. Choosing 50 char will Max 25/50 chars automatically remove COG, SOG and "system" from the Ship's Name message. MMSI number When disabling one or more fields the additional text field will be Course Over Ground...
Step 1 Status and Message Log Connect the Ethernet LAN cable to the RJ45 connector on the Iridium SSAS Box. Status log A status log is maintained in the Iridium SSAS Box to provide Step 2 information to the user about failed connections to the GPS and the Set up the configuration table in the Iridium SSAS Box to have only Iridium Transceiver.
Trouble shooting The status LED on the Iridium SSAS Box will flash in case the communication with the GPS or the Iridium Transceiver fails. (Refer cable connection) Slow flashing: No contact with Iridium transceiver unit Fast flashing: GPS signal is missing or the check sum is wrong Factory reset The SSAS control box can be reset by removing power from the Unit.