Electrical Adjustments
Group/
Item Name
Item
73 HINOR_VALU_FAN_MAX
74 CLHIGH_TEMP_FAN1_MIN
75 ClHIGH_TEMP_FAN1_MAX
76 CLHIGH_TEMP_FAN_MIN
77 CLHIGH_TEMP_FAN_MAX
78 CLHIGH_VALU_FAN1_MIN
79 CLHIGH_VALU_FAN1_MAX
80 CLHIGH_VALU_FAN_MIN
81 CLHIGH_VALU_FAN_MAX
8 CLNOR_TEMP_FAN1_MIN
83 CLNOR_TEMP_FAN1_MAX
84 CLNOR_TEMP_FAN_MIN
85 CLNOR_TEMP_FAN_MAX
86 CLNOR_VALU_FAN1_MIN
87 CLNOR_VALU_FAN1_MAX
88 CLNOR_VALU_FAN_MIN
89 CLNOR_VALU_FAN_MAX
90 FAN_1_AUTO_ADJ
91 FAN__AUTO_ADJ
9 FACTORY_STD_FAN_VOL_MIN
93 FACTORY_STD_FAN_VOL_MAX
94 FAN1_ADJUST_VOLT_MIN
95 FAN1_ADJUST_VOLT_MAX
96 FAN_ADJUST_VOLT_MIN
97 FAN_ADJUST_VOLT_MAX
98 TEMP_ERROR_DETECT_MAX_
TIMES
99 FAN_1_MIN_VOL_LAMP_DIFF
100 FAN__MIN_VOL_LAMP_DIFF
101 LAMP_VOL_BORDER_LINE
10 LAMP_VOL
103 Dimmer Voltage Change Cycle
104 Dimmer Average Check Period
105 Dimmer Voltage Change rate
106 Dimmer Average
107 Last Voltage Difference
108 Voltate Difference Goal
109 Temp Diff High
110 Temp Diff Normal
111 Temp Diff High High
11 Temp Diff Normal High
113 Temp Diff High Ceil
114 Temp Diff Normal Ceil
115 Temp Up Time High
116 Temp Up Time Normal
117 Temp Up Time High High
118 Temp Up Time Normal High
119 Temp Up Time High Ceil
10 Temp Up Time Normal Ceil
11 Standby Cooling Check Cycle
1 Standby Cooling Start Threshold
13 SAfter Shutdown Cooling
14 OnStart Cooling Start Threshold
Group 60 Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration
1 Loop Count
 Auto Status
3 AutoWait
4 CHECK -Tolelance
Group 61 Auto Calibration (RGB)
0 OFFSET AREA H START
1 OFFSET AREA V START
 GAIN AREA H START
Function
FAN Control Max Value in High-land
Normal
FAN1 Control Start Temperature in Ceiling
High
FAN1 Control End Temperature in Ceiling
High
FAN Control Start Temperature in Ceiling
High
FAN Control End Temperature in Ceiling
High
FAN1 Control Min Value in Ceiling High
FAN1 Control MaxValue in Ceiling High
FAN Control Min Value in Ceiling High
FAN Control MaxValue in Ceiling High
FAN1 Control Start Temperature in Ceiling
Normal
FAN1 Control End Temperature in Ceiling
Normal
FAN Control Start Temperature in Ceiling
Normal
FAN Control End Temperature in Ceiling
Normal
FAN1 Control Min Value in Ceiling Normal
FAN1 Control MaxValue in Ceiling Normal
FAN Control Min Value in Ceiling Normal
FAN Control MaxValue in Ceiling Normal
0: OFF (Manual), 1: ON (Auto)
0: OFF (Manual), 1: ON (Auto)
For Factory Adjustment Ref FAN Voltage
Min (Initial 5V)
For Factory Adjustment Ref FAN Voltage
Min (Initial 13.5V)
For Factory Adjustment FAN1 Drive Volt-
age Min
For Factory Adjustment FAN1 Drive Volt-
age Max
For Factory Adjustment FAN Drive Volt-
age Min
For Factory Adjustment FAN Drive Volt-
age Max
Temp Failure when The Sensor detects an
error X times sequentially
Up Volume of FAN1 Control Min
(Unit Vx10)
Up Volume of FAN Control Min
(Unit Vx10)
Threshold Lamp Volatge of the above
items
(Unit Vx10)
Current Lamp Voltage (V)
(Effective 30 sec. after turn on)
Voltage Change Cycle at Dimmer (Unit:
sec)
Measuring Time at Dimmer (Unit: sec)
Voltage Change Volume at Dimmer (Unit:
0.1V)
Avarage Value of Dimmer
Last Voltage defferential Value
Target Voltage Dif. Value at Dimmer (Unit:
10V)
Maximum Execution Times (OFFSET-
>GAIN)
Result of Auto-Calibration (Last Memory)
Wait Value for each setting
Torelance of OFFSET
Black Level Acquiring Area H-Start Position
Black Level Acquiring Area V-Start Position
White Level Acquiring Area H-Start
Position
Initial
115
9
39
9
39
70
135
80
130
30
38
30
38
60
15
60
115
-
-
50
135
40
10
10
10
5
0
0
70
-
3
10
1
-
-
-
0
0
0
0
0
0
0
0
0
0
0
0
5
54
1
38
0
10
0
1

975
500
5
-37-
Range
Note
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-55
0-1
0-1
0-55
0-55
0-55
* Fan Voltage adjustment
0-55
* Fan Voltage adjustment
0-55
* Fan Voltage adjustment
0-55
* Fan Voltage adjustment
1-9
0-0
0-0
30-90
0-55
* Read only
1-?
1-?
1-?
-
* Read only
-
* Read only
-
* Read only
0: No, 1: Yes
0-100
Executes Auto-Calibration when
0 - 1
changiing the Value (PC White 100%)
1 - 30
0 / 1 / 9
0: OK, 1: Adjusting,: Error * ReadOnly
1 - 0
1 - 55
0 - 1000
0 - 1000
0 - 1000