NewAire HG2500 User Manual

Hydroxyl generator air treatment system

Advertisement

Hydroxyl Generator
Air Treatment System
HG2500
User Manual
IMPORTANT SAFETY INSTRUCTIONS
Carefully read the important safety and maintenance information.
Keep these instructions for future reference.
These instructions contain important safety and operating information for
your Newaire HG2500 Hydroxyl Generator. Please contact us directly with
questions you may have regarding the safe operation and/or maintenance.
Toll Free #: 1-877-646-9663

Advertisement

Table of Contents
loading

Summary of Contents for NewAire HG2500

  • Page 1 Carefully read the important safety and maintenance information. Keep these instructions for future reference. These instructions contain important safety and operating information for your Newaire HG2500 Hydroxyl Generator. Please contact us directly with questions you may have regarding the safe operation and/or maintenance. Toll Free #: 1-877-646-9663...
  • Page 2: Table Of Contents

    Table of Contents Important Safety Information ........................2 Handling and Disposal of Mercury ......................4 FAQs ................................ 5 Location of Controls ..........................6 Operation ..............................7 Replacing the Carbon Filters ........................8 Replacing the UV Bulbs .......................... 9 Cleaning ..............................11 Replacement Parts ..........................
  • Page 3: Important Safety Instructions

    Important Safety Information Standard safety precautions must always be followed to 16. The AC mains plug is used as the power disconnect reduce the risk of fire, electric shock, and injury to persons, device and it should remain readily accessible and including the following: operable during intended use.
  • Page 4: Handling And Disposal Of Mercury

    Handling and Disposal of Mercury Mercury is used in this device’s UV bulb and must be disposed of properly. There is no safety hazard as long as the bulb is intact because the mercury is contained within the fixture. If a bulb breaks, very little mercury could be released. This is different then liquid metallic mercury (like in a thermometer), which is hazardous due to its potential to release mercury vapor.
  • Page 5: Faqs

    Handling and Disposal of Mercury • After cleaning, open a window and use a fan to ventilate • Dispose of contaminated items properly! Mercury- the area to the outdoors for 24-48 hours before resuming contaminated items should not be placed in the regular normal use.
  • Page 6: Location Of Controls

    Location of Controls Plastic End Cap Carrying Handle Continuous Power Indicator Switch Timer Knob Plastic End Cap Fuse (bottom of unit) AC Cord — 6 —...
  • Page 7: Operation

    Operation Standard Continuous Operation Timer Operation Plug the unit in as shown in step 1 in the previous Plug into properly section, Standard Continuous Operation. installed and grounded three- prong outlet. See Set the desired timer time using Timer Knob. Note safety precautions as that the knob does not move as the unit is running.
  • Page 8: Replacing The Carbon Filters

    Place used carbon filter in a plastic bag and dispose of. Repeat for the other carbon filter located on the opposite side. IMPORTANT The HG2500 should never be operated without the screen or carbon filter in place. — 8 —...
  • Page 9: Replacing The Uv Bulbs

    Replacing the UV Bulbs When one of UV bulbs blows, you must replace both at the same time. The UV bulbs can be purchased from www.ozoneexperts.com. Replace UV bulbs as follows: WITH THE UNIT UNPLUGGED, place the Hydroxyl Remove one of the 8/32 screws holding the finger guard in its place and loosen the opposing screw.
  • Page 10 Replacing the UV Bulbs Gently pull the UV lamp socket vertically holding the Reconnect the power supply, then reinsert socket lamp by ceramic portion and disconnect the Quick head screws and gently tighten with 5/64 Allen key. Connect connector. Repeat process with the second UV lamp as they Replace the UV lamp with the new bulb by carefully should be replaced in pairs.
  • Page 11: Cleaning

    Replacing the UV Bulbs Reinsert carbon filter, metal retaining screen, and plastic end cap, then secure with retaining screws. WARNING: • UV Bulbs MUST be disposed of properly, see pages 4 and 5 for details on removing the mercury containing UV bulbs.
  • Page 12: Specifications

    Specifications Power Source ...............................120 V, 60 Hz Power Consumption ............................65 Watts Fan Output ................................ 212 CFM Treatment Process .......... UVC 254 NM germicidle chambers, UVC 254 nm germicidle chambers UV Lamp Type ........................Carbon filter & twin hydroxyl Reaction Surface ....................266.90 Square Inches, 25,000 Hour Life Room Capacity .............................2500 Square Feet Dimensions ........................8.2 (W) x 10 (D) x 17 (L) inches Weight ...................................
  • Page 13: Limited Warranty

    Limited Warranty PURCHASER PLEASE FILL OUT AND FAX TO 1-800-493-4550 OR MAIL TO: QUEENAIRE TECHNOLOGIES, INC 9483 State Highway 37, Ogdensburg, NY 13669 MODEL # ________________ SERIAL # ____________________ DATE PURCHASED __________________ PURCHASED FROM ______________________________ INTENDED USE____________________________ CUSTOMER NAME _______________________________ TELEPHONE ______________________________ ADDRESS________________________________________________ FAX _____________________________ CITY/STATE/ZIP _______________________________ CONTACT NAME ____________________________ QUEENAIRE TECHNOLOGIES, INC WARRANTS NEW QUEENAIRE MODELS TO THE ORIGINAL PURCHASER ONLY, TO BE...
  • Page 14 QUEENAIRE TECHNOLOGIES, INC 9483 State Highway 37 Ogdensburg, NY 13669 www.queenaire.com...