Viking Range vcwb300 Installation Instructions Manual

Built-in full height

Advertisement

Quick Links

INSTALLATION
INSTRUCTIONS
BUILT-IN FULL HEIGHT WINE CELLAR
(VCWB300 PROFESSIONAL MODEL)
Retain for Future Reference
IMPORTANT - PLEASE READ AND FOLLOW
Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage,
amperage, and phase is attached to the product.
To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified
people in accordance with all applicable codes and standards, including fire-rated construction.
The installer should leave these instructions with the consumer who should retain them for local inspector's use and for
future reference.

GENERAL INFORMATION

Y Y o o u u r r s s a a f f e e t t y y a a n n d d t t h h e e s s a a f f e e t t y y o o f f o o t t h h e e r r s s
i i s s v v e e r r y y i i m m p p o o r r t t a a n n t t . .
We have provided many important safety
messages in this manual and on your
appliance. Always read and obey all
safety messages.
This is the safety alert symbol. This
symbol alerts you to hazards that
can kill or hurt you and others.
All safety messages will be
preceded by the safety alert symbol and
the word "DANGER" or "WARNING".
These words mean:
Y Y o o u u w w i i l l l l b b e e k k i i l l l l e e d d o o r r s s e e r r i i o o u u s s l l y y i i n n j j u u r r e e d d i i f f y y o o u u
d d o o n n ' ' t t f f o o l l l l o o w w i i n n s s t t r r u u c c t t i i o o n n s s . .
Y Y o o u u c c a a n n b b e e k k i i l l l l e e d d o o r r s s e e r r i i o o u u s s l l y y i i n n j j u u r r e e d d i i f f
y y o o u u d d o o n n ' ' t t f f o o l l l l o o w w i i n n s s t t r r u u c c t t i i o o n n s s . .
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
T T I I P P O O V V E E R R H H A A Z Z A A R R D D
W W i i n n e e c c e e l l l l a a r r i i s s t t o o p p h h e e a a v v y y a a n n d d t t i i p p s s e e a a s s i i l l y y
w w h h e e n n n n o o t t c c o o m m p p l l e e t t e e l l y y i i n n s s t t a a l l l l e e d d . .
K K e e e e p p d d o o o o r r c c l l o o s s e e d d a a n n d d s s h h e e l l v v e e s s i i n n p p l l a a c c e e
u u n n t t i i l l w w i i n n e e c c e e l l l l a a r r i i s s c c o o m m p p l l e e t t e e l l y y i i n n s s t t a a l l l l e e d d
p p e e r r i i n n s s t t a a l l l l a a t t i i o o n n i i n n s s t t r r u u c c t t i i o o n n s s . .
U U s s e e t t w w o o o o r r m m o o r r e e p p e e o o p p l l e e t t o o m m o o v v e e a a n n d d
i i n n s s t t a a l l l l w w i i n n e e c c e e l l l l a a r r . .
F F a a i i l l u u r r e e t t o o d d o o s s o o c c a a n n r r e e s s u u l l t t i i n n d d e e a a t t h h o o r r
s s e e r r i i o o u u s s i i n n j j u u r r y y . .
It is your responsibility to :
-comply with installation specifications and dimensions
-properly install wine cellar
-remove any moldings or decorative panels that prevent the wine cellar
from being serviced
-assure that floor will support wine cellar, door panels and contents
(approximately 1200 lbs. [540 kg]).
-provide a properly grounded electrical outlet
-assure that location will permit appliance doors to open 90
VIKING RANGE CORPORATION
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
M M o o s s t t o o f f t t h h e e w w i i n n e e c c e e l l l l a a r r ' ' s s w w e e i i g g h h t t i i s s a a t t t t h h e e
t t o o p p . . E E x x t t r r a a c c a a r r e e i i s s n n e e e e d d e e d d w w h h e e n n m m o o v v i i n n g g
t t h h e e w w i i n n e e c c e e l l l l a a r r t t o o p p r r e e v v e e n n t t t t i i p p p p i i n n g g . .
U U s s e e c c a a r r d d b b o o a a r r d d s s h h i i p p p p i i n n g g m m a a t t e e r r i i a a l l o o r r
p p l l y y w w o o o o d d u u n n d d e e r r w w i i n n e e c c e e l l l l a a r r u u n n t t i i l l i i t t i i s s
i i n n s s t t a a l l l l e e d d i i n n t t h h e e o o p p e e r r a a t t i i n n g g p p o o s s i i t t i i o o n n t t o o
p p r r o o t t e e c c t t f f l l o o o o r r s s u u r r f f a a c c e e . .
o
minimum

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the vcwb300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Viking Range vcwb300

  • Page 1: General Information

    INSTRUCTIONS (662) 455-1200 BUILT-IN FULL HEIGHT WINE CELLAR (VCWB300 PROFESSIONAL MODEL) Retain for Future Reference IMPORTANT - PLEASE READ AND FOLLOW Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product.
  • Page 2 BASIC SPECIFICATIONS AND DIMENSIONS D D E E S S C C R R I I P P T T I I O O N N V V C C W W B B 3 3 0 0 0 0 Overall Width 30”...
  • Page 3: Features Of Your Wine Cellar

    FEATURES OF YOUR WINE CELLAR 1. TriTemp storage system 8. High temperature alarm (behind grille) 2. Electronic control center 9. Door alarm (behind grille) 3. Convertible display shelves (2) 10. Connection to home security system (behind grille) 4. Extendable shelves (13) 11.
  • Page 4 SITE PREPARATIONS AND CONSIDERATIONS PROFESSIONAL MODEL 30” W. FULL HEIGHT WINE CELLAR CABINET OPENING DIMENSIONS 8 8 4 4 1 1 / / 1 1 6 6 ( ( 2 2 1 1 3 3 . . 5 5 ) ) c c m m m m a a x x . . a a n n t t i i - - t t i i p p b b o o a a r r d d a a n n d d o o p p e e n n i i n n g g h h e e i i g g h h t t 8 8 2 2 7 7 / / 8 8 m m i i n n .
  • Page 5: Electrical Requirements

    AREA REQUIREMENTS V V e e r r i i f f y y t t h h e e f f o o l l l l o o w w i i n n g g : : •Wine cellar can fit into residence and can be moved around corners and through doorways.
  • Page 6 DOOR SWING AND TIPPING CONSIDERATIONS 15 1/2” (39.4 cm) 11 1/2” (29.2 cm) 2 1/2” (6.4 cm) 48 5/8” (123.5 50 1/2” (128.2 cm) 51 7/8” (131.8 cm) 87 1/2 85 1/2 (222.2 cm) (217.1 cm) 112 1/2 106 1/2 (285.7 cm) (270.5 cm) B B A A C C K K W W A A R R D D...
  • Page 7 WINE CELLAR - OVERALL DIMENSIONS 82 7/8” (210.5 cm) min. 84 1/16” (213.5 cm)
  • Page 8: Cabinet Information

    CABINET INFORMATION Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-5/16” (5.9 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room 29 1/2” (90.2 cm) 29 1/2”...
  • Page 9 CABINET INFORMATION (continued) 29 1/2” (90.2 cm) Wall 3/4” (1.9 cm) 24” (61.0 cm) Full end Standard panel 1 13/16” (4.6 cm) cabinet space if 24” (61.0 cm) depth standard cabinet depth used 2 5/16” DOOR (5.9 cm) Partial Overlay Offset Cabinet Door C C - - C C...
  • Page 10 CUSTOM SIDE PANEL DIMENSIONS For 3/4” (1.9 cm) Side Panels 2 2 2 2 3 3 / / 8 8 ” ” 2 2 2 2 3 3 / / 8 8 ” ” ( ( 5 5 6 6 . . 9 9 c c m m ) ) ( ( 5 5 6 6 .
  • Page 11 CUSTOM WOOD FACINGS DIMENSIONS Each wine rack has a wood facing which can be removed. The facings can be stained, painted, or removed and replaced with alternative wood facings. NOTE: A scrap sample should be tested in the unit before attaching permanent changes to your wine cellar fronts.
  • Page 12: Wine Cellar Installation

    WINE CELLAR INSTALLATION T T I I P P O O V V E E R R H H A A Z Z A A R R D D W W i i n n e e c c e e l l l l a a r r i i s s t t o o p p h h e e a a v v y y a a n n d d t t i i p p s s e e a a s s i i l l y y U U s s e e t t w w o o o o r r m m o o r r e e p p e e o o p p l l e e t t o o m m o o v v e e a a n n d d i i n n s s t t a a l l l l w w h h e e n n n n o o t t c c o o m m p p l l e e t t e e l l y y i i n n s s t t a a l l l l e e d d .
  • Page 13: Home Security System Connection

    HOME SECURITY SYSTEM CONNECTION N N O O T T E E : : Contact a qualified electrician or authorized agent from alarm company to connect your home security system to the wine cellar. Home security system connection must be hooked up before the unit is installed. 1) Remove the four mounting screws attaching the unit compartment cover to the cabinet.
  • Page 14 E E l l e e c c t t r r i i c c a a l l S S h h o o c c k k H H a a z z a a r r d d D D i i s s c c o o n n n n e e c c t t p p o o w w e e r r a a t t b b r r e e a a k k e e r r o o r r t t u u r r n n p p o o w w e e r r d d i i s s c c o o n n n n e e c c t t s s w w i i t t c c h h t t o o O O F F F F p p o o s s i i t t i i o o n n b b e e f f o o r r e e p p e e r r f f o o r r m m i i n n g g a a n n y y i i n n s s t t a a l l l l a a t t i i o o n n p p r r o o c c e e d d u u r r e e .
  • Page 15 Before moving the wine cellar in place, confirm the finished dimensions, electrical location, minimum door and shelf clearances, and door panel instructions. (See pages 3, 4, & 5). 1. Position wine cellar in front of cutout. 2. Verify operation by plugging power cord in receptacle.
  • Page 16: Kickplate Installation

    KICKPLATE INSTALLATION The kickplate consists of a two (2) part assembly: one top louvered panel and one bottom solid panel. Install the kickplate with louvered section on the top. Flooring must allow the kickplate to be removed. See “Site Preparations” for height clearance (page 3).
  • Page 17 WIRING DIAGRAM BUILT-IN FULL HEIGHT WINE CELLAR...
  • Page 18 VIKING 111 Front Street • Greenwood, Mississippi 38930 USA • (662) 455-1200 Specifications subject to change without notice F20155E (PS0305VR)

Table of Contents